scholarly journals Research on the Electromagnetic Interference of Yanmenguan DC Grounding Electrode on West-East Transmission Gas Pipeline

2021 ◽  
Vol 1828 (1) ◽  
pp. 012061
Author(s):  
Weiguang Shi ◽  
Kesheng Wang ◽  
Wei Liu ◽  
Pingwei Li ◽  
Xinjing Cai
2020 ◽  
Vol 56 (2) ◽  
pp. 1162-1170
Author(s):  
Dimitris Chrysostomou ◽  
Andreas Dimitriou ◽  
Nikolaos D. Kokkinos ◽  
Charalambos A. Charalambous

Energies ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1279 ◽  
Author(s):  
Lianguang Liu ◽  
Zebang Yu ◽  
Zhe Jiang ◽  
Jianhong Hao ◽  
Wenlin Liu

In order to research the electromagnetic interference in buried oil and gas pipelines generated by the grounding current of a grounding electrode of Ultra High Voltage Direct Current (UHVDC) system, observation experiments of stray current and pipe-to-soil potential (PSP) in the pipeline were carried out. Monitoring devices were installed at two sites of the Dong-Huang oil pipeline before the commissioning of the Zalute–Qingzhou and Shanghaimiao–Shandong ±800 kV UHVDC projects. Monitoring data on the stray current and PSP of the two monitoring sites were obtained when the two UHVDC projects were operated in monopolar mode on 24 December 2017 and 2 January 2019 and the grounding current reached 6250 A. The amplitude characteristics of the stray current and PSP at different distances from the grounding electrode and the effects of the magnitude of the stray current and PSP on the cathodic protection system are analyzed herein. The results show that the effects of the grounding current on pipeline corrosion are not only closely related to the distance between the grounding electrode and the pipeline but are also related to the running state of the potentiostats of pipelines and the distance between insulation flanges. Optimizing the performance of potentiostats and the distribution of insulation flanges can reduce the effects of UHVDC grounding current on pipeline corrosion.


2020 ◽  
pp. 38-44
Author(s):  
A. V. Polyakov ◽  
M. A. Ksenofontov

Optical technologies for measuring electrical quantities attract great attention due to their unique properties and significant advantages over other technologies used in high-voltage electric power industry: the use of optical fibers ensures high stability of measuring equipment to electromagnetic interference and galvanic isolation of high-voltage sensors; external electromagnetic fields do not influence the data transmitted from optical sensors via fiber-optic communication lines; problems associated with ground loops are eliminated, there are no side electromagnetic radiation and crosstalk between the channels. The structure and operation principle of a quasi-distributed fiber-optic high-voltage monitoring system is presented. The sensitive element is a combination of a piezo-ceramic tube with an optical fiber wound around it. The device uses reverse transverse piezoelectric effect. The measurement principle is based on recording the change in the recirculation frequency under the applied voltage influence. When the measuring sections are arranged in ascending order of the measured effective voltages relative to the receiving-transmitting unit, a relative resolution of 0,3–0,45 % is achieved for the PZT-5H and 0,8–1,2 % for the PZT-4 in the voltage range 20–150 kV.


2013 ◽  
Vol 51 (11) ◽  
pp. 813-820
Author(s):  
Chi-Eun Sung ◽  
Hyeon-Jee Jeon ◽  
Jin-Kyung Lee ◽  
In-Soo Son ◽  
Sang-Pill Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document