scholarly journals Design of die adjustment component vector decomposition method for metal screw forming

2021 ◽  
Vol 2020 (1) ◽  
pp. 012007
Author(s):  
C C Wen ◽  
C H Chiu
2021 ◽  
Vol 13 (9) ◽  
pp. 168781402110476
Author(s):  
Shun Hu Zhang ◽  
Li Zhi Che

In this paper, the nonlinear specific plastic power of the Mises criterion is integrated analytically to establish the rolling force model of gradient temperature rolling for an ultra-heavy plate by a new method called the root vector decomposition method. Firstly, the sinusoidal velocity field is proposed in terms of the characteristics of metal flow during ultra-heavy plate rolling, which satisfies the kinematically admissible condition. Meanwhile, the characteristics of the temperature distribution along the thickness direction of the plate during the gradient temperature rolling is described mathematically. Based on the velocity field and the temperature distribution expression, the rolling energy functional is obtained by using the root vector decomposition method, and the analytical solution of rolling force is derived according to the variational principle. Through comparison and verification, the rolling force model solved by the root vector decomposition method in this paper is in good agreement with the measured one, and the maximum error of the rolling force is just 10.21%.


Optimization ◽  
1975 ◽  
Vol 6 (4) ◽  
pp. 549-559
Author(s):  
L. Gerencsér

2018 ◽  
Vol 77 (11) ◽  
pp. 945-956 ◽  
Author(s):  
N. N. Kolchigin ◽  
M. N. Legenkiy ◽  
A. A. Maslovskiy ◽  
А. Demchenko ◽  
S. Vinnichenko ◽  
...  

2020 ◽  
Vol 2020 (14) ◽  
pp. 293-1-293-7
Author(s):  
Ankit Manerikar ◽  
Fangda Li ◽  
Avinash C. Kak

Dual Energy Computed Tomography (DECT) is expected to become a significant tool for voxel-based detection of hazardous materials in airport baggage screening. The traditional approach to DECT imaging involves collecting the projection data using two different X-ray spectra and then decomposing the data thus collected into line integrals of two independent characterizations of the material properties. Typically, one of these characterizations involves the effective atomic number (Zeff) of the materials. However, with the X-ray spectral energies typically used for DECT imaging, the current best-practice approaches for dualenergy decomposition yield Zeff values whose accuracy range is limited to only a subset of the periodic-table elements, more specifically to (Z < 30). Although this estimation can be improved by using a system-independent ρe — Ze (SIRZ) space, the SIRZ transformation does not efficiently model the polychromatic nature of the X-ray spectra typically used in physical CT scanners. In this paper, we present a new decomposition method, AdaSIRZ, that corrects this shortcoming by adapting the SIRZ decomposition to the entire spectrum of an X-ray source. The method reformulates the X-ray attenuation equations as direct functions of (ρe, Ze) and solves for the coefficients using bounded nonlinear least-squares optimization. Performance comparison of AdaSIRZ with other Zeff estimation methods on different sets of real DECT images shows that AdaSIRZ provides a higher output accuracy for Zeff image reconstructions for a wider range of object materials.


Sign in / Sign up

Export Citation Format

Share Document