scholarly journals Grid connected inverter with harmonic suppression based on DSP control

Author(s):  
Fei Xia ◽  
Zongze Xia ◽  
Peixian Cong ◽  
Zhixiong Yang ◽  
Hanbiao Song ◽  
...  
2021 ◽  
Author(s):  
Hao Hou ◽  
Shengguo Zhang ◽  
Jiawei Yang ◽  
Weiwen Hu

2021 ◽  
Vol 2136 (1) ◽  
pp. 012015
Author(s):  
Shengqing Li ◽  
Xinluo Li ◽  
Qiang Wu ◽  
Xiafei Long

Abstract In order to further optimize the output current harmonic suppression effect of photovoltaic grid-connected inverters, a composite control strategy of LCL type photovoltaic grid-connected inverter output current is proposed. This strategy combines proportional complex integral (PCI) control and repetitive control (RC) in parallel, draws a composite control block diagram, introduces a transfer function, and designs PCI and RC control parameters. Prove that the compound control can reduce current harmonics, achieved the purpose of reducing the steady-state error of the fundamental frequency. And adopts a new PCI composite control strategy, which helps to save the cost of the control system. By building the MATLAB/Simulink simulation platform and establishing the PCI+RC composite control model of LCL photovoltaic grid-connected inverter, the comparison of the simulation results shows that compared with the PI+RC control strategy, the total harmonic distortion rate of the grid-connected current is reduced by 25.77. %, significantly improving the quality of grid-connected current.


Author(s):  
Wanwan Xu ◽  
Bin Wang ◽  
Jiang Liu ◽  
Da Li

This paper presents an improved droop control strategy for grid-connected inverter power stability and power quality under distorted with consideration of grid fluctuation and inter-harmonics. An instantaneous frequency without PLL and amplitude of capacitor voltage feed-forward control strategy is given to power stability control, meanwhile a grid current feedback control is given by an incomplete derivation with a high-pass filter, so that the harmonics and inter-harmonics current can be suppressed. These approaches can provide both good active and reactive power dynamic response under fluctuation of frequency, and rejection ability against harmonic and inter-harmonic voltage. Based on model of inverter, the proposed control strategies are designed in detail. Simulations and experiments are present to validate the effectiveness of proposed method.


2020 ◽  
Vol 18 (5) ◽  
pp. 1349-1356
Author(s):  
Congliang Fei ◽  
Pengfei Xiahou ◽  
Fujun Wang

Purpose This study aims to focus on the grid connected inverter. Design/methodology/approach The grid connected inverter for harmonic suppression was designed, the topological structure of the inverter and the design of LCL filter were analyzed, then a PIR controller was proposed and finally simulation and experiment were carried out. Findings The simulation results showed that the distortion rates of the 5th, 7th and 11th harmonics under PIR control were 0.14%, 0.13% and 0.06%, respectively, which were significantly lower than that under PI control. The system test results also showed that the current waveform under PI control was rough and total harmonic distortion (THD) content was 3.8%; under PIR control, the grid connected current waveform was relatively smooth, with fewer spikes and burrs, and the THD content was 1.9%, indicating that the harmonics were effectively suppressed. Originality/value The experimental results verify that the inverter and PIR controller designed in this study are effective for harmonic suppression. This work makes some contributions to the improvement of the effect of harmonic suppression and promotion of the better application of grid connected inverter.


Sign in / Sign up

Export Citation Format

Share Document