scholarly journals A Large Temperature Difference Thermal Substation (LTDTS) with Electric Heat Pump and Thermal Storage Tank

2021 ◽  
Vol 661 (1) ◽  
pp. 012016
Author(s):  
Jian Sun ◽  
Shicai Ma ◽  
Cheng Huo ◽  
Zhihua Ge ◽  
Shaoxiang Zhou
Author(s):  
Jielin Luo ◽  
Qin Wang ◽  
Zhen Zhao ◽  
Kaiyin Yang ◽  
Guangming Chen ◽  
...  

Abstract Considering the issues of environmental pollution and energy efficiency, heat pumps are gradually replacing traditional coal combustion for heating at low ambient temperatures. In this paper, eco-friendly CO2/HCs with large temperature glides are applied in a single-stage recuperative heat pump water heater. Its heating performance is theoretically investigated under the working condition of producing circulating hot water in typical winter of northern China, with medium temperature difference between supply/return water and large temperature difference between air inlet and water inlet. Due to its simple structure, low initial investment and high efficiency, its potential for producing circulating hot water is demonstrated. Exergy analyses are conducted to reveal the significant influence of the exergy losses of heat exchanger on system performance. For specified CO2/HC, optimal COP is obtained through global optimization of cycle pressures and mixture concentration. The heating performances of different CO2/HCs are compared, among which CO2/R600 and CO2/R600a behave better. Meanwhile, a typical vapor-injection cycle is used to demonstrate priorities on the heating performance of this recuperative cycle, in which the COP of recuperative cycle using CO2/R600 is more than 3.4% higher than that of the vapor-injection cycle. The results obtained in this paper provide a simple and efficient solution for producing circulating hot water at low ambient temperatures.


2020 ◽  
Vol 44 (9) ◽  
pp. 3771-3776
Author(s):  
Zhigang Peng ◽  
Chen Chen ◽  
Qian Feng ◽  
Yong Zheng ◽  
Huan Liu ◽  
...  

We synthesized a retarder, which has excellent thickening performance in the temperature range of 90–150 °C.


2001 ◽  
Vol 2001.54 (0) ◽  
pp. 75-76
Author(s):  
Nobuyuki FUCHIMOTO ◽  
Kazuyoshi MATSUZAKI ◽  
Kazunori KOURA ◽  
Sinya WAKAMIZU ◽  
Hiroaki KURISIMA ◽  
...  

2016 ◽  
Vol 847 ◽  
pp. 479-484 ◽  
Author(s):  
Ya Lu ◽  
Ming Li ◽  
Zi Han Guo ◽  
Xiao Yang Guo

In view of the common polymer retarder of AMPS has poor sedimentation stability for slurry in high temperature, and thickening curve for unusual problems, a new terpolymers retarder PSIH which can solve the problem for the large temperature difference was synthesized by free radical aqueous solution copolymerization using styrene sulfonate (SSS), Itaconic acid (IA) and unsaturated hydroxyl ester monomers X . The structure and thermal stability of the copolymer was characterized with gel permeation chromatography (GPC), infrared spectroscopy (IR), and thermal gravimetric analysis (TG). The application performance of the retarder was assessed. The results demonstrated as follows. 1) The preferred synthesis conditions of the retarder is: the mass ratio of SSS/IA/X=9: 3: 1, temperature=60°C, initiator concentration =2%, the reaction time=5h, pH value was controlled in the neutral bias acidity. 2) Synthetic copolymer is the target product with appropriate molecular weight and has good thermal stability with thermal decomposition temperature of the main chain up to 375°C. 3) Compared with ordinary retarder the PSIH has merits as follows: excellent thermal resistant ability and sedimentation stability in high temperature; the rapid development of compressive strength in low temperature, and a big temperature span (30 °C~150 °C). The thickening time of the slurry with 1.0% PSIH is 245 min at 150°C; the compressive strength of cement with the same dosage can get up to 4.7MPa at 30 °C. In short, PSIH has excellent ability to cope with large temperature difference, providing a strong technical support for complex deep well cementing.


Sign in / Sign up

Export Citation Format

Share Document