scholarly journals Simulation of the static synchronous compensator for the electrical system with non-linear load

2021 ◽  
Vol 1035 (1) ◽  
pp. 012024
Author(s):  
A V Makarov ◽  
T V Makarova ◽  
D S Morozov
Author(s):  
Aleksei V. Makarov ◽  
Valeriy G. Makarov ◽  
Tatiana V. Makarova ◽  
Aleksei A. Petrov

The purpose of the work is developing a simulation model of factory’s the power system, with a nonlinear load model, which is a 12-pulses thyristor invertor and a model of a static synchronous compensator, which is multi-level voltage invertor, based on H-bridge invertor. Also defining preliminary parameters for the design of a static synchronous compensator in order to meet the requirements for power factors and limits of voltage harmonic and interharmonic distortion specified for the point of common connection to the mains supply. The analytical and numerical methods of mathematical programming and control of electromechanical systems were used. VisualStudio and PSIM software products for developing a control system for electromechanical systems and compiling a simulation model of an industrial power supply system were used. As a result of the research, a simulation model of the power supply system of an industrial enterprise, a model of a nonlinear load and a static synchronous compensator were developed. The rated power of the static synchronous compensator is determined to reduce the consumption of reactive power and the magnitude of the higher harmonics of the current, at the point of common connection, during operating a non-linear load.


2018 ◽  
Vol 14 (2) ◽  
pp. 172-184
Author(s):  
Saurabh Mani Tripathi ◽  
Prakash Ji Barnawal

AbstractThis paper presents a systematic procedure to design a simple control for a three-phase VSC-based static synchronous compensator (STATCOM) in order to overcome the problems caused by the presence of the non-linear load at the point of common coupling (PCC). The proposed control method regulates the STATCOM in such a way that the source quadrature current component is forced to be zero so that only the active current component is drawn from the source and the harmonic and reactive current demands of the non-linear load are met by the STATCOM. The tuning of the inner and outer loop PI controllers is carried out with the help of the modulus optimum and symmetric optimum criteria, respectively. At last, a few case studies are presented using MATLAB simulation to exemplify the success of the proposed control method.


Sign in / Sign up

Export Citation Format

Share Document