scholarly journals Assessment of Seismic Resistance of Islamic Architecture Monuments on the Example of the Great Mosque of Aleppo taking into account the Seismic Zoning of the Territory of Syria

2021 ◽  
Vol 1079 (5) ◽  
pp. 052036
Author(s):  
T A Belash ◽  
Z A Aldrebi
2018 ◽  
Vol 12 (3) ◽  
pp. 73-80
Author(s):  
Y.I. Pimchin ◽  
V.A. Naugolnov ◽  
G.A. Naumenko ◽  
I.U. Pimchin

2020 ◽  
pp. 122-127
Author(s):  
A. A. Tarasenko ◽  
P. V. Chepur ◽  
A. A. Gruchenkova
Keyword(s):  

Author(s):  
Vladimir A. Lapin ◽  
Erken S. Aldakhov ◽  
S. D. Aldakhov ◽  
A. B. Ali

For the first time in Almaty full passport of apartment stock of multiapartment building was carried out. The structure of the housing stock was revealed with the allocation of groups of buildings according to structural solutions and assessment of their seismic resistance. Based on the results of certification, quantitative estimates of failure probability values for different types of buildings were obtained. Formulas for estimation of quantitative value of seismic risk are obtained. The number of deaths in the estimated zem-shakes was estimated. The results of the assessments will be used for practical recommendations to reduce risk and expected losses in possible earthquakes.


2007 ◽  
Vol 87 (1) ◽  
pp. 35-52 ◽  
Author(s):  
B. A. Baitanayev ◽  
Yu. A. Yolgin
Keyword(s):  

Author(s):  
Fayu Wang ◽  
Nicholas Kyriakides ◽  
Christis Chrysostomou ◽  
Eleftherios Eleftheriou ◽  
Renos Votsis ◽  
...  

AbstractFabric reinforced cementitious matrix (FRCM) composites, also known as textile reinforced mortars (TRM), an inorganic matrix constituting fibre fabrics and cement-based mortar, are becoming a widely used composite material in Europe for upgrading the seismic resistance of existing reinforced concrete (RC) frame buildings. One way of providing seismic resistance upgrading is through the application of the proposed FRCM system on existing masonry infill walls to increase their stiffness and integrity. To examine the effectiveness of this application, the bond characteristics achieved between (a) the matrix and the masonry substrate and (b) the fabric and the matrix need to be determined. A series of experiments including 23 material performance tests, 15 direct tensile tests of dry fabric and composites, and 30 shear bond tests between the matrix and brick masonry, were carried out to investigate the fabric-to-matrix and matrix-to-substrate bond behaviour. In addition, different arrangements of extruded polystyrene (XPS) plates were applied to the FRCM to test the shear bond capacity of this insulation system when used on a large-scale wall.


Sign in / Sign up

Export Citation Format

Share Document