Immunocytochemistry with Cytokeratin 19 and Anti-Human Mesothelial Cell Antibody (HBME1) Increases the Diagnostic Accuracy of Thyroid Fine-Needle Aspirations: Preliminary Report of 150 Liquid-Based Fine-Needle Aspirations with Histological Control

Thyroid ◽  
2011 ◽  
Vol 21 (10) ◽  
pp. 1067-1073 ◽  
Author(s):  
Beatrix Cochand-Priollet ◽  
Henri Dahan ◽  
Marie Laloi-Michelin ◽  
Marc Polivka ◽  
Michele Saada ◽  
...  
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
J. Ratour ◽  
M. Polivka ◽  
H. Dahan ◽  
L. Hamzi ◽  
R. Kania ◽  
...  

Aim. We aimed to analyze the diagnostic criteria proposed by the Bethesda System for Reporting Thyroid Cytopathology for follicular lesions of undetermined significance (FLUS), the risk of cancer and diagnostic improvement with use of immunocytochemistry.Methods. For each FLUS diagnosis, we analyzed the cytological criteria (9 Bethesda criteria), secondary fine-needle aspiration (FNA) results, surgical procedures, contribution of immunocytochemistry with the antibodies cytokeratin 19 (CK19) and monoclonal anti-human mesothelial cell (HBME1).Results. Among patients with 2,210 thyroid FNAs, 244 lesions (337 nodules) were classified as FLUS (11% of all thyroid FNAs). The 3 criteria most often applied were cytological atypia suggesting papillary carcinoma (36%), microfollicular architecture but sparse cellularity (23.1%), cytological atypia (21.5%). With secondary FNA, 48.8% of nodules were reclassified as benign. For about half of all cases (41.4% for the first FNA, 57.6% for the second FNA), immunocytochemistry helped establishing a diagnosis favoring malignant or benign. No benign immunocytochemistry results were associated with a malignant lesion. In all, 22.5% of the 39 removed nodules were malignant.Conclusion. The FLUS category is supported by well-described criteria. The risk of malignancy in our series was 22.5%. Because we had no false-negative immunocytochemistry results, immunocytochemistry could be helpful in FLUS management.


2021 ◽  
pp. 1-7
Author(s):  
Shruti Agrawal ◽  
Michael Leonard Anthony ◽  
Pranoy Paul ◽  
Divya Singh ◽  
Akansha Agarwal ◽  
...  

<b><i>Background:</i></b> Fine-needle aspiration biopsy (FNAB) in breast lesions offers accurate results in differentiating benign and malignant lesions. However, its role is unclear when core-needle biopsy (CNB) is available, the latter providing additional information regarding tumor grade, invasion, and hormone receptor status in malignant lesions. In benign breast lesions, especially in BIRADS category 4a and 4b, FNAB, and CNB provide similar pathological information, whereby FNAB may serve as a more rapid and cost-effective investigation. The study was planned to reevaluate the diagnostic accuracy of FNAB in BIRADS category 4a, 4b, and 4c lesions. <b><i>Materials and Methods:</i></b> FNAB and biopsy reports of all patients with breast lesions sent between September 1, 2018, and November 30, 2020, were collected and the International Academy of Cytology (IAC) Yokohama category and BIRADS score were recorded for each case. The rate of malignancy and the accuracy of FNAB in diagnosing malignancy were calculated for each BIRADS 4a, 4b, and 4c subgroup. <b><i>Results:</i></b> A total of 249 cases of BIRADS 4 lesions had corresponding cytology and histopathology diagnoses. FNAB showed high diagnostic accuracy in all BIRADS groups. A benign categorization was associated with a very low number of false-negative diagnoses, especially in BIRADS 4a lesions. <b><i>Conclusion:</i></b> The study reconfirms the excellent accuracy of breast FNAB using the IAC Yokohama system in diagnosing breast malignancies. Furthermore, BIRADS 4a lesions found to be belonging to the cytological benign category may be excluded from CRB and kept on clinical follow-up.


Endoscopy ◽  
2021 ◽  
Author(s):  
Dongwook Oh ◽  
Joonseog Kong ◽  
Sung Woo Ko ◽  
Seung-Mo Hong ◽  
Hoonsub So ◽  
...  

Abstract Background Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) are the current standard of care for sampling pancreatic and peripancreatic masses. Recently, a 22G EUS-FNB needle with Franseen geometry was developed, and this device was also introduced in a 25G platform. We compared the performance of the 25G and 22G Franseen needles for EUS-guided sampling of pancreatic and peripancreatic solid masses. Methods We conducted a parallel-group randomized non-inferiority trial at a tertiary-care center from November 2018 to May 2019. The primary outcome was the quality of the histologic core assessed using the Gerke score. The optimal histologic core is indicated by a Gerke score of 4 or 5, which enables optimal histologic interpretation. The overall diagnostic accuracy and adverse event rate were also evaluated. Results 140 patients were enrolled and randomized (1:1) to the 25G and 22G groups. Tissue acquisition by EUS-FNB was successful in all patients. The optimal histologic core procurement rate was 87.1 % (61/70) for the 25G needle vs. 97.1 % (68/70) for the 22G; difference −10 % (95 % confidence interval −17.35 % to −2.65 %). High quality specimens were more frequently obtained in the 22G group than in the 25G group (70.0 % [49/70] vs. 28.6 % [20 /70], respectively; P < 0.001). The overall diagnostic accuracy did not differ between the groups (97.4 % for 25G vs. 100 % for 22G). Conclusions The 25G Franseen needle was inferior to the 22G needle in histologic core procurement. Therefore, for cases in which tissue architecture is pivotal for diagnosis, a 22G needle, which procures relatively higher quality specimens than the 25G needle, should be used.


2021 ◽  
Vol 49 (2) ◽  
pp. 030006052098268
Author(s):  
Mingli Yuan ◽  
Yafei Wang ◽  
Wen Yin ◽  
Yang Xiao ◽  
Manman Hu ◽  
...  

Objective To evaluate the efficacy of rapid on-site cytological evaluation (ROSE) in determining specimen adequacy and diagnostic accuracy in the interventional diagnosis of lung lesions. Methods This retrospective study included 127 consecutive cases of lung lesions, which were sampled by bronchoscopy or transthoracic fine needle aspiration, and diagnosed on ROSE followed by histopathology. ROSE was performed by a trained pulmonologist and the diagnosis of ROSE was compared with the final diagnosis. Results The sensitivity of ROSE in determining adequacy of specimens was 97.5% and specificity in determining inadequacy was 85.7%. The diagnostic efficacy of ROSE for assessing malignancy (sensitivity of 94.5% and specificity of 100%) and non-malignancy (sensitivity of 97.8% and specificity of 100%) was excellent. The sensitivity of ROSE for diagnosing small cell carcinoma (100%) was highest, followed by adenocarcinoma (89.2%) and squamous cell carcinoma (75.0%). Performance of ROSE by a trained pulmonologist also determined tuberculosis with a high diagnostic sensitivity (83.3%) and specificity (100%). Conclusions A trained pulmonologist can reliably carry out ROSE to ensure the adequacy of the sample, distinguish between malignancy and non-malignancy, and make a preliminary diagnosis in a large number of cases.


2021 ◽  
Author(s):  
Gabriele Delconte ◽  
Federica Cavalcoli ◽  
Andrea Magarotto ◽  
Giovanni Centonze ◽  
Cristina Bezzio ◽  
...  

Introduction: Fine Needle Biopsy (FNB) has been suggested to provide better histological samples as compared to endoscopic ultrasound fine needle aspiration (EUS-FNA). However, studies comparing EUS-FNA and EUS-FNB for pancreatic lesions reported contrasting results. The aim of this study was to compare the clinical performance of EUS-FNA versus EUS-FNB with ProCore needle for the investigation of pancreatic lesions. Methods: We reviewed all patients undergoing EUS for the investigation of pancreatic lesions from August 2012 to September 2018. From August 2012 to January 2015 all procedures were performed with standard needles, whereas from February 2015 to September 2018 the use of ProCore needles had been introduced. Data on diagnostic accuracy, number of needle passes and/or adverse events were collected. Results: 324 patients were retrospectively evaluated: 190 (58.6%) underwent EUS-FNA and 134 (41.4%) EUS-FNB. Both EUS-FNA and EUS-FNB showed high diagnostic accuracy for malignancy [94% (CI 95%:89-97%) vs 94% (CI 95%:89-98%)]. Notable, there were no differences between EUS-FNA and EUS-FNB in terms of sensitivity, specificity, positive and negative likelihood ratio, histological core tissue retrieval, adverse events or number of needle passes. However, subgroup analysis noted a higher diagnostic accuracy for 25G EUS-FNB as compared to 25G EUS-FNA (85,7% vs 55,5%; *p=0.023). Conclusion: EUS-FNB with ProCore needle is safe and feasible in pancreatic lesions. ProCore needle did not provide any advantage in terms of diagnostic accuracy, sensitivity, specificity, positive and/or negative likelihood ratio, or acquisition of core specimen, therefore its routine application is not


Sign in / Sign up

Export Citation Format

Share Document