scholarly journals 3: Comparison of Point-of-Care and Central Laboratory Methods for the Measurement of Cardiac Troponin I in Patients With Suspected Acute Myocardial Infarction

2015 ◽  
Vol 143 (suppl_1) ◽  
pp. A002-A002 ◽  
Author(s):  
Miroslav Sekulic ◽  
Victor Santiago ◽  
Pedro Castaneda ◽  
Eric Christianson ◽  
Gregory Loppnow ◽  
...  
2011 ◽  
Vol 135 (4) ◽  
pp. 459-463
Author(s):  
Elizabeth Lee-Lewandrowski ◽  
James L Januzzi ◽  
Ricky Grisson ◽  
Asim A Mohammed ◽  
Grant Lewandrowski ◽  
...  

Abstract Context.—Previous studies evaluating point-of-care testing (POCT) for cardiac biomarkers did not use current recommendations for troponin cutoff values or recognize the recent universal definition of acute myocardial infarction. Traditionally, achieving optimal sensitivity for the detection of myocardial injury on initial presentation required combining cardiac troponin and/or creatine kinase isoenzyme MB with an early marker, usually myoglobin. In recent years, the performance of central laboratory combining cardiac troponin assays has improved significantly, potentially obviating the need for a multimarker panel to achieve optimum sensitivity. Objective.—To compare 2 commonly used POCT strategies to a fourth generation, central laboratory cardiac troponin T assay on first-draw specimens from patients being evaluated for acute myocardial infarction in the emergency department. The 2 strategies included a traditional POCT multimarker panel and a newer POCT method using cardiac troponin I alone. Design.—Blood specimens from 204 patients presenting to the emergency department with signs and/or symptoms of myocardial ischemia were measured on the 2 POCT systems and by a central laboratory method. The diagnosis for each patient was determined by retrospective chart review. Results.—The cardiac troponin T assasy alone was more sensitive for acute myocardial infarction than the multimarker POCT panel with equal or better specificity. When compared with a POCT troponin I, the cardiac troponin T was also more sensitive, but this difference was not significant. The POCT troponin I alone also had the same sensitivity as the multimarker panel. Conclusions.—Testing for combining cardiac troponin alone using newer, commercially available, central laboratory or POCT assays performed with equal or greater sensitivity to acute myocardial infarction as the older, traditional, multimarker panel. In the near future, high-sensitivity, central laboratory troponins will be available for routine clinical use. As a result, the quality gap between central laboratories and older POCT methods will continue to widen, unless the performance of the POCT methods is improved.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Florian Leuschner ◽  
Jin Li ◽  
Stefan Göser ◽  
Lars Reinhardt ◽  
Renate Öttl ◽  
...  

Application of antibodies against cardiac troponin I (cTnI-Ab) can induce dilation and dysfunction of the heart in mice. Recently, we demonstrated that immunization with cTnI induces inflammation and fibrosis in myocardium of mice. Others have shown that autoanti-bodies to cTnI are present in patients with acute coronary syndrome. But little is known about the clinical relevance of detected cTnI-Ab. First, anti-cTnI and anti-cTnT antibody titers were measured in sera from 272 patients with dilated- (DCM) and 185 with ischemic- (ICM) cardiomyopathy. Secondly, 108 patients with acute myocardial infarction (AMI) were included for a follow-up study. Heart characteristics were determined by magnetic resonance imaging 4 days and 6 –9 months after AMI. Altogether, in 7,0% of patients with DCM and in 9,2% with ICM an anti-cTnI IgG antibody titer ≥1:160 was measured. In contrast, only in 1,7% of patients with DCM and in 0,5% with ICM an anti-cTnT IgG antibody titer ≥1:160 was detected. Ten out of 108 patients included in the follow-up study were tested positive for cTnI-Ab with IgG Ab titers ≥1:160. TnI-Ab negative patients showed a significant increase in LVEF and stroke volume 6 –9 months after AMI. In contrast, there was no significant increase in LVEF and stroke volume in TnI-Ab positive patients. We demonstrate for the first time that the prevalence of cTnI-Abs in patients with AMI has an impact on the improvement of the LVEF over a study period of 6 –9 months.


1994 ◽  
Vol 40 (7) ◽  
pp. 1291-1295 ◽  
Author(s):  
J E Adams ◽  
K B Schechtman ◽  
Y Landt ◽  
J H Ladenson ◽  
A S Jaffe

Abstract Although measurement of cardiac troponin I (cTnI) is, in some situations, more specific for detection of cardiac injury than is measurement of the MB isoenzyme of creatine kinase (MBCK), its sensitivity and specificity relative to MBCK for detection of myocardial infarction has not been established. Accordingly, we studied prospectively 199 consecutive patients admitted to the coronary care unit. Values of MBCK and cTnI mass were determined in all samples. Of the 188 patients admitted with a suspicion of acute myocardial ischemia, 89 were diagnosed as having an acute myocardial infarction on the basis of the patterns of MBCK values. Eighty-six of these patients also had increased cTnI (concordance, 96.6%); three did not. Of the patients diagnosed as without infarction, five with unstable angina and symptoms in the day(s) prior to admission had increased cTnI, for a cTnI specificity of 94.9%. Receiver operating characteristic curve analysis indicated that cTnI and MBCK had statistically indistinguishable diagnostic accuracies for the detection of acute myocardial infarction.


1997 ◽  
Vol 134 (4) ◽  
pp. 622-630 ◽  
Author(s):  
Milenko J. Tanasijevic ◽  
Christopher P. Cannon ◽  
Donald R. Wybenga ◽  
George A. Fischer ◽  
Christine Grudzien ◽  
...  