scholarly journals Implantation of three transcatheter aortic valves for embolization of two valves caused by under-expansion: a case report

Author(s):  
Masaki Tsuda ◽  
Ryu Shutta ◽  
Masami Nishino ◽  
Jun Tanouchi

Abstract Background Transcatheter aortic valve embolization is one of the serious complications of transcatheter aortic valve implantation (TAVI). We present a case of TAVI that needed implantation of three transcatheter aortic valves owing to the embolization of two self-expandable valves (SEVs). Case summary An 88-year-old woman underwent TAVI using a 26-mm SEV. After valve deployment, the SEV embolized to the ascending aorta during the removal of the delivery system (DS) of the SEV (DS-SEV) from the SEV. An additional SEV was implanted, which also embolized upwards. Multi-directional fluoroscopy revealed extreme under-expansion of the second SEV, which caused valve embolization due to catching of the DS-SEVs in the SEVs. Finally, a 23-mm balloon-expandable valve was successfully implanted, which was also under expanded on fluoroscopic assessment. The patient was stable without sequelae at the 1-month follow-up. Discussion Pre-procedurally predicting SEV under-expansions was difficult because pre-procedural computed tomography revealed no massive calcification on the aortic valve, and fluoroscopy indicated adequate expansion of the SEVs at the angle where the valves were deployed. We verified the possibility of catching of a DS-SEV in an under-expanded SEV in an in vitro test, which showed that the DS-SEV was caught in the extremely under-expanded SEV. Furthermore, balloon dilation might release the catch of the DS-SEV by changing the DS-SEV position. Therefore, we recommend performing multi-directional fluoroscopy to evaluate SEV expansion before DS-SEV removal from an SEV. Furthermore, if catching of a DS-SEV occurs, balloon dilation might be useful for releasing the catch and safely removing the DS-SEV.

Open Heart ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. e001496
Author(s):  
Tiffany Patterson ◽  
Harriet Hurrell ◽  
Jack Lee ◽  
Giulia Esposito ◽  
Utkarsh Dutta ◽  
...  

AimsDurability of transcatheter aortic valve implantation (TAVI) is key to its expansion. We sought to identify incidence of valve thrombosis and predictors of valve thrombosis in our single centre with associated coagulation testing pre-TAVI and post-TAVI.Methods and resultsThis single-centre observational study comprised patients undergoing transfemoral TAVI discussed in the Heart Team meeting . Patients were followed up with echocardiography at 120 days to identify incidence of elevated transvalvular gradient and multivariable analysis was performed to identify factors associated with an increased odds of developing valve thrombosis. In addition, 11 patients underwent baseline, day 1 and day 120 post-TAVI coagulation testing. Between August 2017 and August 2019, 437 consecutive patients underwent transfemoral TAVI. Of these patients, 207/437 (47.4%) had 3-month follow-up echo data available and were analysed. Of these patients, 26/207 (12.6%) had elevated transvalvular gradients. These patients tended to be younger (80±14 vs 83±6 years; p=0.047) with a lower ejection fraction (49±13 vs 54%±11%; p=0.021), with a greater proportion of the population experiencing atrial fibrillation (14/21, 54% vs 68/181, 38%; p=0.067). Following multivariable analysis, there remained a trend towards higher eccentricity index associated with elevated gradients. Baseline (pre-TAVI) elevation of thrombin antithrombin levels (56±63; reference range 1.0–4.1 ng/L) and PF 1+2 (791±632; reference range 69–229 ng/mL) normalised at 120 days post-TAVIConclusionThis study demonstrated that in the cohort of patients undergoing transfemoral TAVI in our centre: younger age, poor ejection fraction, atrial fibrillation and increased baseline eccentricity of the aortic valve annulus were present to a greater extent in patients exhibiting elevated transvalvular gradients at 3-month follow-up. Further work is required to delineate the extent of coagulation derangement and confirm predictors of thrombosis.


2021 ◽  
Vol 10 (3) ◽  
pp. 431
Author(s):  
Danuta Sorysz ◽  
Rafał Januszek ◽  
Anna Sowa-Staszczak ◽  
Anna Grochowska ◽  
Marta Opalińska ◽  
...  

Transcatheter aortic valve implantation (TAVI) is now a well-established treatment for severe aortic stenosis. As the number of procedures and indications increase, the age of patients decreases. However, their durability and factors accelerating the process of degeneration are not well-known. The aim of the study was to verify the possibility of using [18F]F-sodium fluoride ([18F]F-NaF) and [18F]F-fluorodeoxyglucose ([18F]F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing the intensity of TAVI valve degenerative processes. In 73 TAVI patients, transthoracic echocardiography (TTE) at initial (before TAVI), baseline (after TAVI), and during follow-up, as well as transesophageal echocardiography (TEE) and PET/CT, were performed using [18F]F-NaF and [18F]F-FDG at the six-month follow-up (FU) visit as a part of a two-year FU period. The morphology of TAVI valve leaflets were assessed in TEE, transvalvular gradients and effective orifice area (EOA) in TTE. Calcium scores and PET tracer activity were counted. We assessed the relationship between [18F]F-NaF and [18F]F-FDG PET/CT uptake at the 6 = month FU with selected indices e.g.,: transvalvular gradient, valve type, EOA and insufficiency grade at following time points after the TAVI procedure. We present the preliminary PET/CT ([18F]F-NaF, [18F]F-FDG) results at the six-month follow-up period as are part of an ongoing study, which will last two years FU. We enrolled 73 TAVI patients with the mean age of 82.49 ± 7.11 years. A significant decrease in transvalvular gradient and increase of effective orifice area and left ventricle ejection fraction were observed. At six months, FU valve thrombosis was diagnosed in four patients, while 7.6% of patients refused planned controls due to the COVID-19 pandemic. We noticed significant correlations between valve types, EOA and transaortic valve gradients, as well as [18F]F-NaF and [18F]F-FDG uptake in PET/CT. PET/CT imaging with the use of [18F]F-FDG and [18F]F-NaF is intended to be feasible, and it practically allows the standardized uptake value (SUV) to differentiate the area containing the TAVI leaflets from the SUV directly adjacent to the ring calcifications and the calcified native leaflets. This could become the seed for future detection and evaluation capabilities regarding the progression of even early degenerative lesions to the TAVI valve, expressed as local leaflet inflammation and microcalcifications.


Author(s):  
Eliano Pio Navarese ◽  
Leonardo Grisafi ◽  
Enrico Spinoni ◽  
Marco Giovanni Mennuni ◽  
Andrea Rognoni ◽  
...  

Background. The optimal pharmacological therapy after transcatheter aortic valve implantation (TAVI) remains uncertain. We compared efficacy and safety of various antiplatelet and anticoagulant approaches after TAVI by a network meta-analysis. Methods. A total of 14 studies (both observational and randomized) were considered, with 24,119 patients included. Primary safety endpoint was the incidence of any bleeding complications during follow-up. Secondary safety endpoint was major bleeding. Efficacy endpoints were stroke, myocardial infarction and cardiovascular mortality. A frequentist network meta-analysis was conducted with a random-effects model. The following strategies were compared: dual antiplatelet therapy (DAPT), single antiplatelet therapy (SAPT), oral anticoagulation (OAC), OAC+SAPT. Mean follow-up was 15 months. Results. In comparison to DAPT, SAPT was associated with a 44% risk reduction of any bleeding (OR, 0.56 [95% CI, 0.39-0.80]). SAPT was ranked as the safest strategy for the prevention of any bleeding (P-score, 0.704), followed by OAC alone (P-score, 0.476) and DAPT (P-score, 0.437). Consistent results were observed for major bleeding. The incidence of cardiovascular death and secondary ischemic endpoints did not differ among the tested antithrombotic approaches. In patients with indication for long-term anticoagulation, OAC alone showed similar rates of stroke (OR 0.92 [95% CI 0.41-2.05], p=0.83) and reduced occurrence of any bleeding (OR 0.49 [95% CI 0.37-0.66], p<0.01) vs OAC+SAPT. Conclusions. The present network meta-analysis supports after TAVI the use of SAPT in patients without indication for OAC and OAC alone in those needing long-term anticoagulation.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
T J Carvalho Mendonca ◽  
L Patricio ◽  
M Oliveira ◽  
I Rodrigues ◽  
G Portugal ◽  
...  

Abstract Introduction Transcatheter aortic valve implantation (TAVI) is an established treatment in patients (P) with aortic stenosis. Despite the continuous developments of this procedure, high-grade conduction disturbances requiring permanent pacemaker (PPM) implantation is still a major and common complication of TAVI. Furthermore, long-term chronic right ventricular pacing has been associated with negative effects on ventricular function and heart failure (HF). Aim   to evaluate the long-term impact of PPM after TAVI focusing on mortality and HF hospitalization. Methods  We retrospectively examined P who underwent TAVI with a self-expanding valve from 2009 to 2018 at our institution. All P had pre-procedural clinical evaluation, including ECG, cardiac computed tomographic angiography and transthoracic echocardiography. P with previous PPM were excluded. Results  265P (57% male, mean age 81.4 years, 20% with left ventricular ejection fraction &lt;40%) were analysed. Mean STS score and mean Euroscore II were 6.33% and 7.07%, respectively. Mean transvalvular gradient was 52.78 mmHg and mean aortic valve area 0.67 cm2. Forty-seven P (17%) underwent PPM implantation during the first 30 days after TAVI. P requiring PPM had higher prevalence of diabetes mellitus, chronic renal disease, atrial fibrillation and right bundle branch block. During a mean follow-up of 20.3 months, post-TAVI PPM was associated with similar mortality rate (29.8% vs. 25.6%, HR 1.28, 95% CI 0.72-2.29, p = 0.42) and similar cardiovascular mortality (9.8% vs. 6.4%, HR 0.72, 95% CI 0.21-2.4, p = 0.59) compared to P without PPM. There were no significant differences in HF hospitalization (4.9% vs. 2.4%, p = 0.47). Kaplan-Meier curves of total mortality and cardiovascular mortality according to the need for PPM post-TAVI were similar.  Conclusions  In P submitted to TAVI, PPM implantation is a relatively common finding, not associated with higher risk of total mortality, cardiovascular mortality or HF hospitalization in a long-term follow-up.


2013 ◽  
Vol 6 (1) ◽  
pp. 92-93 ◽  
Author(s):  
Alberto M. Leopaldi ◽  
Riccardo Vismara ◽  
Guido Gelpi ◽  
Claudia Romagnoni ◽  
Gianfranco B. Fiore ◽  
...  

2020 ◽  
Vol 7 (12) ◽  
pp. 201838
Author(s):  
Romina Plitman Mayo ◽  
Halit Yaakobovich ◽  
Ariel Finkelstein ◽  
Shawn C. Shadden ◽  
Gil Marom

Leaflet thrombosis has been suggested as the reason for the reduced leaflet motion in cases of hypoattenuated leaflet thickening of bioprosthetic aortic valves. This work aimed to estimate the risk of leaflet thrombosis in two post-valve-in-valve (ViV) configurations, using five different numerical approaches. Realistic ViV configurations were calculated by modelling the deployments of the latest version of transcatheter aortic valve devices (Medtronic Evolut PRO, Edwards SAPIEN 3) in the surgical Sorin Mitroflow. Computational fluid dynamics simulations of blood flow followed the dry models. Lagrangian and Eulerian measures of near-wall stagnation were implemented by particle and concentration tracking, respectively, to estimate the thrombogenicity and to predict the risk locations. Most of the numerical approaches indicate a higher leaflet thrombosis risk in the Edwards SAPIEN 3 device because of its intra-annular implantation. The Eulerian approaches estimated high-risk locations in agreement with the wall sheer stress (WSS) separation points. On the other hand, the Lagrangian approaches predicted high-risk locations at the proximal regions of the leaflets matching the low WSS magnitude regions of both transcatheter aortic valve implantation models and reported clinical and experimental data. The proposed methods can help optimizing future designs of transcatheter aortic valves with minimal thrombotic risks.


Sign in / Sign up

Export Citation Format

Share Document