Hemoptysis due to a primary aortobronchial fistula of the ascending aorta

Author(s):  
Jaime-Jürgen Eulert-Grehn ◽  
Jana Veit ◽  
Volkmar Falk ◽  
Volker Düsterhöft
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ahmad Ali Amirghofran ◽  
Elahe Nirooei ◽  
Mohammad Ali Ostovan

Abstract Background Pseudoaneurysm of ascending aorta is a rare but serious complication of cardiovascular surgeries and it infrequently occurs in the normal prosthetic graft materials. We share our experience with an unusual case of ascending aorta Dacron graft pseudoaneurysm caused by a fractured sternal wire. Case presentation A 34-year-old man, known case of Marfan syndrome, with history of two prior aortic surgeries for aneurysm of ascending aorta, arch and thoracoabdominal aorta, presented with hemoptysis. The hemoptysis originated from an aortobronchial fistula secondary to a huge ascending aorta Dacron graft pseudoaneurysm. The graft erosion and subsequent pseudoaneurysm was caused by a fractured sternal wire. Surgical repair of the pseudoaneurysm was performed successfully and a Gore-tex patch was placed behind the sternum over the graft to prevent further direct contact of the wire and the graft. Conclusion Sternal wires can damage the adjacent vascular grafts and lead to fatal complications such as pseudoaneurysm formation. Thus, preventive measures such as using sternal bands and placing a covering layer between the sternal wires and aortic grafts are recommended in patients with dilated or replaced ascending aorta.


VASA ◽  
2005 ◽  
Vol 34 (3) ◽  
pp. 181-185 ◽  
Author(s):  
Westhoff-Bleck ◽  
Meyer ◽  
Lotz ◽  
Tutarel ◽  
Weiss ◽  
...  

Background: The presence of a bicuspid aortic valve (BAV) might be associated with a progressive dilatation of the aortic root and ascending aorta. However, involvement of the aortic arch and descending aorta has not yet been elucidated. Patients and methods: Magnetic resonance angiography (MRA) was used to assess the diameter of the ascending aorta, aortic arch, and descending aorta in 28 patients with bicuspid aortic valves (mean age 30 ± 9 years). Results: Patients with BAV, but without significant aortic stenosis or regurgitation (n = 10, mean age 27 ± 8 years, n.s. versus control) were compared with controls (n = 13, mean age 33 ± 10 years). In the BAV-patients, aortic root diameter was 35.1 ± 4.9 mm versus 28.9 ± 4.8 mm in the control group (p < 0.01). The diameter of the ascending aorta was also significantly increased at the level of the pulmonary artery (35.5 ± 5.6 mm versus 27.0 ± 4.8 mm, p < 0.001). BAV-patients with moderate or severe aortic regurgitation (n = 18, mean age 32 ± 9 years, n.s. versus control) had a significant dilatation of the aortic root, ascending aorta at the level of the pulmonary artery (41.7 ± 4.8 mm versus 27.0 ± 4.8 mm in control patients, p < 0.001) and, furthermore, significantly increased diameters of the aortic arch (27.1 ± 5.6 mm versus 21.5 ± 1.8 mm, p < 0.01) and descending aorta (21.8 ± 5.6 mm versus 17.0 ± 5.6 mm, p < 0.01). Conclusions: The whole thoracic aorta is abnormally dilated in patients with BAV, particularly in patients with moderate/severe aortic regurgitation. The maximum dilatation occurs in the ascending aorta at the level of the pulmonary artery. Thus, we suggest evaluation of the entire thoracic aorta in patients with BAV.


2010 ◽  
Vol 58 (S 01) ◽  
Author(s):  
H Deschka ◽  
M Machner ◽  
S El Dsoki ◽  
A Alken ◽  
G Wimmer-Greinecker
Keyword(s):  

2011 ◽  
Vol 59 (S 01) ◽  
Author(s):  
S Schotten ◽  
L Conzelmann ◽  
KF Kreitner ◽  
C Düber ◽  
CF Vahl ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document