scholarly journals Left atrial appendage remodeling following percutaneous closure with WATCHMAN 2.5 and FLX: insights from the WATCH-DUAL registry

2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
K Mahmoudi ◽  
R Galea ◽  
S Elhadad ◽  
L Z Rezine ◽  
F Sebag ◽  
...  

Abstract Background Percutaneous left atrial appendage closure (LAAC) has emerged as a valid option for prevention of thromboembolic events in patients with non-valvular atrial fibrillation and contraindications for oral anticoagulation. The most recent devices have been created to improve the intervention efficiency and to allow the procedure in a wider range of anatomies. The new-generation Watchman FLX (WMFLX) features a new design but its in vivo performances have not been compared to the previous WATCHMAN 2.5 (WM2.5) prosthesis. Hence, the data regarding conformability, compression and device-related LAA remodeling are scarce. Purpose To compare the anatomical results of WM2.5 and WMFLX implantation and impact on LAA dimensions. Methods This study included LAAC patients from the WATCH-DUAL registry who benefited from a pre- and post-intervention CT scan. The WATCH-DUAL study was a dual center observational study including all the LAAC procedures prospectively collected in local registries from two high-volume centres between November 2017 and December 2020. The LAA and device dimensions were measured in a centralized core lab by 3D CT scan reconstruction methods, focusing on the device landing zone (LZ/defined as the cross section of the appendage that was perpendicular to its axis and connected the circumflex artery to a point 1 to 2 cm inside the LAA). Results This analysis included n=107 patients (n=58 WMFLX, n=49 WM2.5). The patients clinical profiles didn't differ, except for a higher proportion of coronary artery disease in WM2.5 group. The LAA dimensions were comparable between groups. There was a significantly higher proportion of chickenwing shapes in the WMFLX patients. The mean device baseline diameter was in the WMFLX compared to the WM2.5 patients (28.8±0.5 vs. 25.7±0.4 mm, p<0.001). The median delay for CT control was 48 (43–62) days. The LZ area (451 (363–521) vs. 366 (260–459) mm2, p<0.001) and minimal diameter (23.0 (20.7–24.8) vs. 18.7 (15.9–21.8) mm, p<0.001) significantly increased after implantation among patients. The LZ area increase absolute value and percentage were 101 (18–151) mm2 and 28 (4–54) % respectively. The LZ dimensions increase was more pronounced in the WMFLX group: these patients exhibited post LAAC larger LZ area and dimensions compared to the WM2.5 cases. The LAA eccentricity was reduced after implantation: the ratio LZ maximal/LZ minimal diameter significantly decreased for all patients (r=1.28 (1.18–1.40) vs. 1.06 (1.05–1.09), p<0.001). Comparable results were observed in WMFLX and WM2.5 patients. A multivariable regression analysis demonstrated that baseline LAA length, baseline LZ eccentricity and WM FLX use were independent predictors of LAA remodeling/dimensions increase. Conclusion LAA dimensions increased over time at the site of WM prosthesis implantation suggesting a local positive appendage remodeling after procedure. This phenomenon appears to be more pronounced with the WMFLX device. FUNDunding Acknowledgement Type of funding sources: None.

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Jonathan H Chung ◽  
Gordon Ho ◽  
Andrew Schluchter ◽  
Francisco Contijoch ◽  
Jonathan C Hsu ◽  
...  

Introduction: The formation of thrombus in the left atrial appendage (LAA) and risk for systemic embolization may result in part from stasis and poor blood volume emptying during atrial fibrillation (AF). Functional 4-dimensional computed tomography (4DCT) is a promising technique to measure LAA ejection fraction and blood volume emptying. Hypothesis: We hypothesize that the LAA ejection fraction measured by 4DCT is decreased during AF compared to sinus rhythm. Methods: 256-slice 4DCT scans obtained in patients for coronary artery imaging or pre-procedurally for AF, VT or SVT ablation procedures were analyzed retrospectively. In each patient, LAA volumes were measured at multiple phases during one cardiac cycle using segmentation software (ITK-SNAP and Osirix MD). LAA ejection fraction was calculated as the difference between minimum and maximum volumes and was analyzed using Wilcoxon rank sum. Results: Out of 54 patients, 37 patients were in sinus rhythm and 17 patients were in AF. Between NSR vs. AF, mean age was 69.1±12.8 vs 73.2±11.5 years (p=0.13), 28% vs 36% female (p=0.54), LVEF was 58±11% vs 60±9% (p=0.95), and echo-derived left atrial volume index was 29.5±6.1 ml/m2 vs 41.7±12.8 ml/m2 (p=0.06). Patients who were in sinus rhythm during their CT scan had a higher LAA ejection fraction than those who were in AF (58±13% vs. 29±9%, p<0.0001). For patients who were in AF during their CT scan, there was no difference in LAA ejection fraction between patients with a history of paroxysmal AF compared to patients with a history of persistent AF (30±10% vs. 28±10%, p=0.75). Conclusions: Analysis of the LAA volumes using functional cardiac CT is a feasible method to quantify blood volume emptying from the LAA. Patients in AF were observed to have significantly decreased LAA ejection fraction and blood volume emptying compared to patients in sinus rhythm. Further studies are needed to determine whether this technique may improve personalized risk stratification for stroke.


Author(s):  
Domenico G. Della Rocca ◽  
Rodney P. Horton ◽  
Nicola Tarantino ◽  
Christoffel Johannes Van Niekerk ◽  
Chintan Trivedi ◽  
...  

Background: Interventional therapies aiming at excluding the left atrial appendage (LAA) from systemic circulation have been established as a valid alternative to oral anticoagulation in patients at high thromboembolic risk. However, their efficacy on stroke prophylaxis may be compromised owing to incomplete LAA closure. Additionally, the need for an alternative thromboembolic prevention may remain unmet in patients with contraindications to oral anticoagulation whose appendage anatomy is unsuitable for some conventional devices commercially available. We aimed at evaluating the feasibility of LAA closure with the novel Gore Cardioform Septal Occluder in patients with incomplete appendage ligation or anatomic features which do not meet the manufacturer’s requirements for Watchman deployment. Methods: Twenty-one consecutive patients (mean age: 72±6 years; 85.7% males; CHA 2 DS 2 -VASc: 4.5±1.4; HAS-BLED: 3.6±1.0) were included. Transesophageal echocardiography was performed within 2 months to assess for residual LAA patency. Results: Fourteen patients had incomplete LAA closure following surgical (n=6) or Lariat ligation (n=8). In 7 patients with an appendage anatomy unsuitable for Watchman deployment, the mean maximal landing zone size and LAA depth were 14.4±1.3 and 18.6±2.8 mm. Successful Cardioform Septal Occluder deployment was achieved in all patients. No peri-procedural complications were documented. Procedure and fluoroscopy times were 46±13 and 14±5 minutes. Follow-up transesophageal echocardiography after 58±9 days revealed complete LAA closure in all patients. Conclusions: Transcatheter LAA closure via a Cardioform Septal Occluder device might be a valid alternative in patients with residual leaks following failed appendage ligation or whose LAA anatomy does not meet the minimal anatomic criteria to accommodate a Watchman device. Graphic Abstract: A graphic abstract is available for this article.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
L Seibolt ◽  
D Verma ◽  
W Mulroy ◽  
A Loli

Abstract Background Left atrial appendage occlusion with Watchman device traditionally relies on accurate left atrial appendage (LAA) ostium diameter measurement by 2D or 3D transesophageal echocardiogram (TEE). Alternate methods of ostium measurement including area-derived diameter and perimeter-derived diameter using cardiac computed tomography (CT) have been proposed. Purpose We aim to use CT technology with an advanced medical imaging application to measure LAA ostium perimeter for improved pre-procedural device sizing. Methods We performed a retrospective analysis of 92 patients with atrial fibrillation (Afib) who underwent Watchman implantation with pre-procedural TEE and cardiac CT between May 2015 and December 2018. LAA characteristics including ostial or landing zone perimeter, minimum and maximum diameters were acquired utilizing 3mensio Structural Heart Imaging Program. Proposed Watchman device size was estimated utilizing ostium perimeter by CT and compared to the current standard utilizing ostium diameter by 2D-TEE. Both measurements were then compared to actual implanted Watchman device size which met the P.A.S.S. criteria of position, anchor, size and seal. Results Watchman device sizing based on novel LAA landing zone perimeter size by CT had a very high correlation with the actual implanted Watchman size (Pearson coefficient r=0.94, p<0.001). Traditional TEE based Watchman sizing only had a modest correlation with the implanted Watchman size (Pearson coefficient r=0.66, p<0.001). CT predicted Watchman size had a significantly higher agreement compared to current standard TEE based sizing (93.4% vs 47.8%), inter-rater agreement was very high for CT based Watchman sizing compared to current standard TEE based sizing (Cohen's kappa = 0.91 vs Cohen's kappa = 0.32, p<0.001, p<0.001 respectively). Bland-Altman analysis also showed better correlation with CT based sizing compared to TEE (see Figure 1). Figure 1 Conclusion CT LAA perimeter sizing is superior to the current standard TEE based Watchman sizing. Larger, multi-center studies may be necessary to further validate our results.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
S Afzal ◽  
V Veulemans ◽  
K Hellhammer ◽  
K Piayda ◽  
N Nijhof ◽  
...  

Abstract Background and purpose Percutaneous left atrial appendage occlusion (LAAO) depicts an alternative treatment for patients with atrial fibrillation who are deemed for long-term oral anticoagulation therapy. In order to perform a successful LAAO accurate sizing of left atrial appendage (ostium, landing zone and depth) for device selection is essential. Echo-Fluoro fusion imaging in real-time offers with its latest prototype a patient-specific segmented automated 3D heart model and sizing of left atrial appendage (LAA). We therefore aimed to evaluate the automated segmented LAA sizing by comparing to 2D transesophageal (TOE) and MSCT measurements as gold standard. Methods We studied prospectively data of 8 consecutive patients who were admitted to our clinic for left atrial appendage closure. MSCT was performed preprocedural and analyzed with commercially available 3mensio software (Pie medical imaging). 2D TOE measurements and automated segmentation of the LAA and sizing were performed during the procedure by a highly experienced team of periinterventional cardiac imaging specialist and structural heart disease interventionalist who were blinded to the prior MSCT analysis. Dimension of ostium, landing zone (10 mm into the LAA parallel to the ostial plane at the level of the left circumflex for Amplatzer device) and depth (perpendicular to the ostial plane) were obtained in different TOE views according to instructions for use of Amulet Occluder. In order to generate an automated 3 D heart model, a high-quality 3D TOE image of the LAA volume and surrounding structures was acquired. After successful ECG-gated segmentation a 3 D heart model was generated. Automated LAA sizing followed in real-time. All measurements were taken into consideration before device selection. A Kruskal Wallis test was used to compare mean ranks of independent samples. A concordance analysis according to Kendall W was carried out to investigate reliability. Results The mean age of the patients was 82,6±4.15 years and half of the patients were female. All procedures were conducted successfully. The mean values of ostium and landing zone were comparable in TOE, automated sizing and MSCT sizing (ostium: 23,78±2,15 mm vs 25,71±5,25 mm vs 27,35±3,3 mm; (p=0,175); landing zone 22,13±3,18 mm vs 23,57±3,31 mm vs 24,00±3,51 mm; (p=0,377)). Furthermore, a significant concordance between the measurements was shown (ostium W= 0,991; p=0.045, landing zone W=0,835, p=0.014). Conclusion Automated LAA sizing acquired by fusion imaging may be an elegant real-time alternative for precise LAA Occluder device selection and needs to be investigated further.


1990 ◽  
Vol 259 (4) ◽  
pp. H1006-H1008 ◽  
Author(s):  
C. A. Davis ◽  
J. C. Rembert ◽  
J. C. Greenfield

Compliance of the left atrial chamber was estimated with and without the appendage intact in six isolated canine left atria. Pressure-volume determinations were measured over a range of 5-30 mmHg for the whole left atrium and were repeated with the appendage excluded. The slope of the pressure vs. normalized volume data for the left atrium without the appendage (10.45 +/- 0.87) was significantly greater (P less than 0.01) than with the appendage intact (4.10 +/- 0.72). These data suggest that the left atrial appendage is more compliant than the remaining left atrium. Assuming that this relationship remains in vivo, the left atrial appendage may play an augmented role in maintaining hemodynamic function when filling pressures are elevated.


Author(s):  
Bayan B. Malakouti-Nejad ◽  
Eliot J. Winkler ◽  
Marjorie I. Johnson ◽  
Jorge Catrip ◽  
Katie L. Losenno ◽  
...  

Objective Conventional epicardial excision is believed to be the most effective method of surgically obliterating the left atrial appendage (LAA), although incomplete resection and residual LAA volume may undermine its effectiveness. We sought to compare the impact of conventional epicardial excision with a novel LAA pericardial patch exclusion on residual LAA volume. Methods We performed LAA obliteration using pericardial patch exclusion, followed by conventional epicardial excision, in 27 cadaveric hearts. After each procedure, residual LAA volume was measured by two different techniques and compared with baseline volume. There was no difference in baseline LAA volume between each procedure. Results Procedural success was achieved in all hearts. Conventional epicardial excision left a residual LAA volume of 0.95 mL (24%), as compared with pericardial patch exclusion, which left a residual volume of 0.17 mL (4%, P = 0.0001). Further analysis of fixed and fresh hearts showed that reduction of LAA volume was more pronounced in the fresh hearts, suggesting effectiveness in live patients. Neither technique resulted in any significant change in the endocardial shape of the LAA orifice or injury to the circumflex artery. Conclusions Conventional epicardial excision of the LAA results in significantly more residual LAA volume, which may have important implications in persistent stroke risk. Pericardial patch exclusion seems to achieve near-total elimination of the LAA and may be a superior surgical option.


2015 ◽  
Vol 86 (1) ◽  
pp. 173-181 ◽  
Author(s):  
Yanping Cheng ◽  
Gerard Conditt ◽  
Genghua Yi ◽  
Armando Tellez ◽  
Michael Corcoran ◽  
...  

2007 ◽  
Vol 0 (0) ◽  
pp. 070726173227012-???
Author(s):  
ILAN GOTTLIEB ◽  
AURÉLIO PINHEIRO ◽  
JEFFREY A. BRINKER ◽  
JOÃO A.C. LIMA ◽  
THEODORE P. ABRAHAM ◽  
...  