scholarly journals Liquid Chromatographic Method for the Simultaneous Determination of Eprosartan and Hydrochlorothiazide in Tablets and Human Plasma

2011 ◽  
Vol 94 (3) ◽  
pp. 823-832 ◽  
Author(s):  
Fathalla Belal ◽  
Amina M El-Brashy ◽  
Nahed El-Enany ◽  
Manar M Tolba

Abstract A new, specific, and sensitive RP-HPLC method was developed for the simultaneous determination of eprosartan (EPR) and hydrochlorothiazide (HCT). Good chromatographic separation was achieved using a 250 × 4.6 mm id, 5 μm particle size Symmetry® C18 column. The mobile phase acetonitrile–0.1 M phosphate buffer (35 + 65, v/v), pH 4.5, was pumped at a flow rate of 1 mL/min, with UV detection at 275 nm. The method showed good linearity in the ranges of 0.5–50 and 0.1–10 μg/mL, with LOD of 0.06 and 0.02 μg/mL and LOQ of 0.20 and 0.08 μg/mL for EPR and HCT, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their synthetic mixture and co-formulated tablets. The method was further extended to the in vitro and in vivo determination of the two drugs in spiked and real human plasma. Interference likely to be encountered from the co-administered drugs was studied.

2013 ◽  
Vol 49 (3) ◽  
pp. 521-528 ◽  
Author(s):  
Viviane Benevenuti Silva ◽  
Angel Arturo Gaona Galdos ◽  
Cintia Maria Alves Mothe ◽  
Michele Bacchi Pallastrelli ◽  
Maria Segunda Aurora Prado ◽  
...  

A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm) with acetonitrile:water 50:50 (v/v) as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.


2011 ◽  
Vol 8 (s1) ◽  
pp. S372-S376 ◽  
Author(s):  
Xiaoying Zhou ◽  
Haoke Zhang ◽  
Liang Ge ◽  
Haiyan Gong ◽  
Shuge Tian

A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in theArctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18column (250×4.6 mm, 5 μm, with pre-column), the mobile phase consists of methanol and water (55: 45). Detection wavelength was 280 nm. The speed of flow was 1.0 mL/min. The specimen handing quantity was 10 μL. The arctiin’s linearity range was 1.575∼4.725 μg (r=0.9995). The arctigenin’s linearity range was 0.613, 3.063 μg (r = 0.9998) and the linear relationship was accurate. The average recovery (n=5) of arctiin and arctigenin were 101.55% (RSD=2.23%) 101.63% (RSD =1.49 %) respectively. The contents of arctiin and arctigenin inArctium tomentosumMill. were 10.69 mg/g and 0.15 mg/g, respectively. Therefore, the developed HPLC method can be applied to bothin vitrostudies of arctiin and arctigenin formulations as well as drug estimation in biological samples.


2019 ◽  
Vol 15 (6) ◽  
pp. 635-641
Author(s):  
Nadia M. Mostafa ◽  
Ghada M. Elsayed ◽  
Nagiba Y. Hassan ◽  
Dina A. El Mously

Background:The concept of green analytical chemistry prevails due to the growing environmental pollution.Objective:Our attempts are to develop simple and eco-friendly method which is non-harmful to the environment by producing minimal waste. In this context, a green liquid chromatographic method was applied for the simultaneous determination of chlorpheniramine maleate, pseudoephedrine hydrochloride and propyphenazone in their combined dosage form.Methods:Separation was carried out using X select HSS RP C18 analytical column (250 × 4.6 mm, 5μm) using methanol - 0.02 M phosphate buffer pH 3 - triethylamine (60:40: 0.1, by volume) as a mobile phase. The separated peaks were detected at 215 nm at a flow rate 1.0 mL/min.Results:Quantification was done over the concentration ranges of 1-25 µg/mL for chlorpheniramine maleate, 5-35 µg/mL for pseudoephedrine hydrochloride and 10-120 µg/mL for propyphenazone. The suggested method was validated with regard to linearity, accuracy and precision according to the International Conference on Harmonization guidelines with good results.Conclusion:It could be used as a safer alternative for routine analysis of the mentioned drugs in quality control laboratories.


2012 ◽  
Vol 2012 ◽  
pp. 1-4 ◽  
Author(s):  
Shravan Bankey ◽  
Ganesh Tapadiya ◽  
Jasvant Lamale ◽  
Deepti Jain ◽  
Shweta Saboo ◽  
...  

A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant.


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


Sign in / Sign up

Export Citation Format

Share Document