scholarly journals Determination of Arctiin and Arctigenin Contents inArctium TomentosumMill. by HPLC Method

2011 ◽  
Vol 8 (s1) ◽  
pp. S372-S376 ◽  
Author(s):  
Xiaoying Zhou ◽  
Haoke Zhang ◽  
Liang Ge ◽  
Haiyan Gong ◽  
Shuge Tian

A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in theArctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18column (250×4.6 mm, 5 μm, with pre-column), the mobile phase consists of methanol and water (55: 45). Detection wavelength was 280 nm. The speed of flow was 1.0 mL/min. The specimen handing quantity was 10 μL. The arctiin’s linearity range was 1.575∼4.725 μg (r=0.9995). The arctigenin’s linearity range was 0.613, 3.063 μg (r = 0.9998) and the linear relationship was accurate. The average recovery (n=5) of arctiin and arctigenin were 101.55% (RSD=2.23%) 101.63% (RSD =1.49 %) respectively. The contents of arctiin and arctigenin inArctium tomentosumMill. were 10.69 mg/g and 0.15 mg/g, respectively. Therefore, the developed HPLC method can be applied to bothin vitrostudies of arctiin and arctigenin formulations as well as drug estimation in biological samples.

2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


2013 ◽  
Vol 49 (3) ◽  
pp. 521-528 ◽  
Author(s):  
Viviane Benevenuti Silva ◽  
Angel Arturo Gaona Galdos ◽  
Cintia Maria Alves Mothe ◽  
Michele Bacchi Pallastrelli ◽  
Maria Segunda Aurora Prado ◽  
...  

A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm) with acetonitrile:water 50:50 (v/v) as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


1982 ◽  
Vol 65 (5) ◽  
pp. 1063-1065
Author(s):  
Stanley E Roberts

Abstract A high performance liquid chromatographic (HPLC) method is described for the quantitative determination of primidone in tablets. A ground tablet sample is diluted directly in the mobile phase, at a concentration of about 1 mg/mL of primidone, mixed and deaerated, and filtered. The resulting solution is then quantitated by HPLC. The average spike recoveries for the 50 mg and 250 mg tablets were 101.2% and 99.0%, respectively. The average recovery for an authentic mixture formulated at the 250 mg level was 100.1% with a relative standard deviation of 0.45%.


Author(s):  
M. Murali ◽  
P. Venkateswara Rao

A simple, selective, linear, precise and accurate isocratic RP-HPLC method was developed and validated for rapid assay of Vandetanib, an anticancer drug, in both bulk and tablet dosage form. Elution at a flow rate of 1ml/min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of acetonitrile, water and orthophosphoric acid in the ratio of 90:08:02 (v/v/v). Linearity was observed in concentration range of 50-200 ppm. The retention time for Vandetanib was 3.326 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of Vandetanib in pharmaceutical dosage forms. Moreover the detection alone was also verified through LC-MS of the Vandetanib drug using ESI method which provides future scope for study of this drug using LC-MS method also.


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


Author(s):  
Abrar Ahmed ◽  
Tayyaba Mahtab ◽  
Sumaiyya Saleem

Midostaurin is a multi-targeted protein kinase inhibitor that has been used for the treatment of acute myeloid leukemia.  Here, a rapid and precise reverse phase high-performance liquid chromatographic method has been developed for the validation of midostaurin, in its API form as well as in capsule dosage form. Chromatography was carried out on a X-Bridge C18 (4.6 x 250 mm, 5 µm) column using a mixture of methanol: water (75:25% v/v) as the mobile phase at a flow rate of 1.0 mL/min, the detection was carried out at 243nm and the retention time of the midostaurin was found to be 3.155. The method produce linear responses in the concentration range of 10-50 µg/mL of midostaurin. The method precision for the determination of assay was below 2.0 % RSD. The LOD and LOQ values obtained were 1.2 µg/mL and 3.8 µg/mL respectively. There were no significant changes observed upon changing chromatographic conditions indicating the method to be robust. Therefore this validated method can be useful in the quality control of bulk and pharmaceutical formulations of midostaurin. 


2015 ◽  
Vol 18 (1) ◽  
pp. 8-14 ◽  
Author(s):  
T Sudha ◽  
K Manthena ◽  
VR Ravikumar ◽  
V Ganesan

A simple gradient reversed phase high performance liquid chromatographic method was developed for the determination of ambroxol hydrochloride in presence of antimicrobial preservatives in oral liquid formulation. The chromatographic separation was achieved by an Inertsil C8 (250 X 4.6 mm, 5? particle size) column using gradient technique. The eluents were detected at 245 nm with photodiode array detector. The optimized mobile phase consisted of 0.1% trifluoroacetic acid as a mobile phase A and a mixture of mobile phase A and acetonitrile in the ratio of 76:24 % v/v as mobile phase B. Ambroxol hydrochloride and microbial preservatives were eluted at a flow rate of 1.0 ml/min. The method validated according to the International Conference of Harmonization (ICH) guidelines. The calibration curves were linear over the (r2 > 0.99) concentrations range from 300 to 900 ppm for ambroxol hydrochloride, 10 to 30 ppm for propyl paraben and 100 to 300 ppm for methyl paraben. The limit of detection was found to be 0.024 ppm for ambroxol hydrochloride, 0.018 ppm for propyl paraben and 0.009 ppm for methyl paraben. The percentage recoveries were found to be in the range from 99.55 to 101.1% for ambroxol hydrochloride, 100.31 to 101.46% for propyl paraben and 98.18 to 101.61% for methyl paraben. Stability indicating capability was established by forced degradation experiments. No chromatographic interference from the degradation products was found. The proposed method was highly sensitive, precision and accurate and hence successfully applied for the quantification of ambroxol active pharmaceutical ingredients (API) and preservatives content in the commercially available oral liquid formulation.Bangladesh Pharmaceutical Journal 18(1): 8-14, 2015


Sign in / Sign up

Export Citation Format

Share Document