scholarly journals The application of numerical estimates of base calling accuracy to DNA sequencing projects

1995 ◽  
Vol 23 (8) ◽  
pp. 1406-1410 ◽  
Author(s):  
James K. Bonfield ◽  
Rodger Staden
Keyword(s):  
2016 ◽  
Vol 7 ◽  
pp. 91-101 ◽  
Author(s):  
Yun Ding ◽  
Anastassia Kanavarioti

The influence of an electric field on an isolated channel or nanopore separating two compartments filled with electrolytes produces a constant ion flux through the pore. Nucleic acids added to one compartment traverse the pore, and modulate the current in a sequence-dependent manner. While translocation is faster than detection, the α-hemolysin nanopore (α-HL) successfully senses base modifications in ssDNA immobilized within the pore. With the assistance of a processing enzyme to slow down translocation, nanopore-based DNA sequencing is now a commercially available platform. However, accurate base calling is challenging because α-HL senses a sequence, and not a single nucleotide. Osmylated DNA was recently proposed as a surrogate for nanopore-based sequencing. Osmylation is the addition of osmium tetroxide 2,2’-bipyridine (OsBp) to the C5–C6 pyrimidine double bond. The process is simple, selective for deoxythymidine (dT) over deoxycytidine (dC), unreactive towards the purines, practically 100% effective, and strikingly independent of length, sequence, and composition. Translocation of an oligodeoxynucleotide (oligo) dA10XdA9 via α-HL is relatively slow, and exhibits distinct duration as well as distinct residual current when X = dA, dT(OsBp), or dC(OsBp). The data indicate that the α-HL constriction zone/β-barrel interacts strongly with both OsBp and the base. A 23 nucleotide long oligo with four dT(OsBp) traverses 18-times slower, and the same oligo with nine (dT+dC)(OsBp) moieties traverses 84-times slower compared to dA20, suggesting an average rate of 40 or 180 μs/base, respectively. These translocation speeds are well above detection limits, may be further optimized, and clear the way for nanopore-based sequencing using osmylated DNA.


1998 ◽  
Vol 70 (13) ◽  
pp. 2676-2684 ◽  
Author(s):  
James H. Flanagan, ◽  
Clyde V. Owens ◽  
Sarah E. Romero ◽  
Emanuel Waddell ◽  
Shaheer H. Kahn ◽  
...  

1999 ◽  
Vol 9 (6) ◽  
pp. 588-595
Author(s):  
Christopher Korch ◽  
Harry Drabkin

The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces base-calling accuracy and limits heterozygous allele detection, favoring use of dye-labeled primers for this purpose. We have discovered that the addition of a manganese salt to the PE Applied Biosystems dye-terminator sequencing kits overcomes these limitations for the older rhodamine dyes as well as the more recent dichloro-rhodamine dyes (dRhodamine and BigDyes). Addition of manganese to reactions containing dRhodamine-based dye terminators produced the highest base-calling accuracy. This combination resulted in the most uniform electropherogram profiles, superior to those produced by BigDye terminators and published for dye primers, and facilitated detection of heterozygous alleles.


1995 ◽  
Vol 49 (10) ◽  
pp. 1528-1533 ◽  
Author(s):  
Qingbo Li ◽  
Edward S. Yeung

Two base-calling schemes for DNA sequencing are evaluated. Both are based on data collected from two broad-band emission channels derived from either one- or two-excitation channels. Standard four-dye Sanger reaction products are used in conjunction with capillary electrophoretic separation in a polymer matrix. Data acquisition is compatible with high light-throughput imaging and minimal data storage. In one scheme, commercial chromatographic software provides peak recognition and peak heights. The peak-height ratios from the two channels provide base-calling accuracies of 99.3% and 97.1% through 330 bp and 350 bp, respectively. In another scheme, ratiograms are derived from the two channels. The resulting step-like functions permit the calling of bases even when successive peaks are not resolved. The base-calling accuracy is 99% through 340 bp. Because of simplicity in implementation, either scheme should be readily applicable to high-speed, high-throughput DNA sequencing in capillary arrays.


Sign in / Sign up

Export Citation Format

Share Document