scholarly journals How to calculate the ASDAS based on C-reactive protein without individual questions from the BASDAI: the BASDAI-based ASDAS formula

Rheumatology ◽  
2019 ◽  
Vol 59 (7) ◽  
pp. 1545-1549 ◽  
Author(s):  
I Concepcion Aranda-Valera ◽  
Juan L Garrido-Castro ◽  
Lourdes Ladehesa-Pineda ◽  
Janitzia Vazquez-Mellado ◽  
Pedro Zarco ◽  
...  

Abstract Objectives To develop a new equation to calculate the Ankylosing Spondylitis Disease Activity Score based on CRP (ASDAS-CRP) using only the BASDAI total score and CRP. Methods Axial SpA (axSpA) patients from the Cordoba Spondyloarthritis Registry cohort were recruited as a derivation cohort, while a retrospective sample from the Spanish Rheumatology Society National Registry of Spondyloarthropathies and Ibero American Spondyloarhtritis Registry registers was used as a validation cohort. We built a new equation based only on the BASDAI and CRP, defining a new formula: the BASDAI-based ASDAS (BASDAS). Linear regression analysis was used to determine the coefficients of the equation in the derivation cohort and it was subsequently validated in the validation cohort. Results A total of 52 axSpA patients in the derivation cohort and 3359 patients in the validation cohort were included. In the derivation cohort, the mean BASDAS [2.24 (s.d. 0.90)] was very similar to the ASDAS-CRP [2.23 (s.d. 0.95)], with a very strong correlation (r = 0.96, P < 0.001). In the validation cohort, the mean BASDAS was 3.31 (s.d. 1.37) and the ASDAS-CRP was 3.19 (s.d. 1.27), which also had a very strong correlation (r = 0.95, P < 0.001). Intraclass correlation coefficients were excellent in both cohorts (0.963 and 0.947, respectively). Conclusion The BASDAS performs similarly to the ASDAS-CRP and can be calculated with only the BASDAI total score and CRP, allowing evaluation of disease activity in retrospective studies where the individual items of the BASDAI are not available.

2003 ◽  
Vol 83 (10) ◽  
pp. 899-906 ◽  
Author(s):  
Deborah Falla ◽  
Gwendolen Jull ◽  
Paul Dall'Alba ◽  
Alberto Rainoldi ◽  
Roberto Merletti

Abstract Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion—the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yunru Liao ◽  
Zhenlan Yang ◽  
Zijing Li ◽  
Rui Zeng ◽  
Jing Wang ◽  
...  

Purpose: Purpose of this study is to evaluate the measuring consistency of central refraction between multispectral refraction topography (MRT) and autorefractometry.Methods: This was a descriptive cross-sectional study including subjects in Sun Yat-sen Memorial Hospital from September 1, 2020, to December 31, 2020, ages 20 to 35 years with a best corrected visual acuity of 20/20 or better. All patients underwent cycloplegia, and the refractive status was estimated with autorefractometer, experienced optometrist and MRT. We analyzed the central refraction of the autorefractometer and MRT. The repeatability and reproducibility of values measured using both devices were evaluated using intraclass correlation coefficients (ICCs).Results: A total of 145 subjects ages 20 to 35 (290 eyes) were enrolled. The mean central refraction of the autorefractometer was −4.69 ± 2.64 diopters (D) (range −9.50 to +4.75 D), while the mean central refraction of MRT was −4.49 ± 2.61 diopters (D) (range −8.79 to +5.02 D). Pearson correlation analysis revealed a high correlation between the two devices. The intraclass correlation coefficient (ICC) also showed high agreement. The intrarater and interrater ICC values of central refraction were more than 0.90 in both devices and conditions. At the same time, the mean central refraction of experienced optometrist was −4.74 ± 2.66 diopters (D) (range −9.50 to +4.75D). The intra-class correlation coefficient of central refraction measured by MRT and subjective refraction was 0.939.Conclusions: Results revealed that autorefractometry, experienced optometrist and MRT show high agreement in measuring central refraction. MRT could provide a potential objective method to assess peripheral refraction.


2018 ◽  
Vol 63 (4) ◽  
pp. 453-460 ◽  
Author(s):  
Vahid Abdollah ◽  
Eric C. Parent ◽  
Michele C. Battié

Abstract Degenerated discs have shorter T2-relaxation time and lower MR signal. The location of the signal-intensity-weighted-centroid reflects the water distribution within a region-of-interest (ROI). This study compared the reliability of the location of the signal-intensity-weighted-centroid to mean signal intensity and area measurements. L4-L5 and L5-S1 discs were measured on 43 mid-sagittal T2-weighted 3T MRI images in adults with back pain. One rater analysed images twice and another once, blinded to measurements. Discs were semi-automatically segmented into a whole disc, nucleus, anterior and posterior annulus. The coordinates of the signal-intensity-weighted-centroid for all regions demonstrated excellent intraclass-correlation-coefficients for intra- (0.99–1.00) and inter-rater reliability (0.97–1.00). The standard error of measurement for the Y-coordinates of the signal-intensity-weighted-centroid for all ROIs were 0 at both levels and 0 to 2.7 mm for X-coordinates. The mean signal intensity and area for the whole disc and nucleus presented excellent intra-rater reliability with intraclass-correlation-coefficients from 0.93 to 1.00, and 0.92 to 1.00 for inter-rater reliability. The mean signal intensity and area had lower reliability for annulus ROIs, with intra-rater intraclass-correlation-coefficient from 0.5 to 0.76 and inter-rater from 0.33 to 0.58. The location of the signal-intensity-weighted-centroid is a reliable biomarker for investigating the effects of disc interventions.


2018 ◽  
Vol 45 (9) ◽  
pp. 1256-1262 ◽  
Author(s):  
Alberto Cauli ◽  
Dafna D. Gladman ◽  
Alessandro Mathieu ◽  
Ignazio Olivieri ◽  
Giovanni Porru ◽  
...  

Objective.Physician’s global assessment (PGA) of disease activity is a major determinant of therapeutic decision making. This study assesses the reliability of the PGA, measured by means of 0–100 mm visual analog scale (VAS), and the additional use of separate VAS scales for musculoskeletal (PhysMSK) and dermatologic (PhysSk) manifestations in patients with psoriatic arthritis (PsA).Methods.Sixteen centers from 8 countries enrolled 319 consecutive patients with PsA. PGA, PhysMSK, and PhysSk evaluation forms were administered at enrollment (W0) and after 1 week (W1). Detailed clinical data regarding musculoskeletal (MSK) manifestations, as well as dermatological assessment, were recorded.Results.Comparison of W0 and W1 scores showed no significant variation (intraclass correlation coefficients were PGA 0.87, PhysMSK 0.86, PhysSk 0.78), demonstrating the reliability of the instrument. PGA scores were dependent on PhysMSK and PhysSk (p < 0.0001) with a major effect of the MSK component (B = 0.69) compared to skin (B = 0.32). PhysMSK was correlated with the number of swollen joints, tender joints, and presence of dactylitis (p < 0.0001). PhysSk scores were correlated with the extent of skin psoriasis and by face, buttocks or intergluteal, and feet involvement (p < 0.0001). Finally, physician and patient assessments were compared showing frequent mismatch and a scattered dot plot: PGA versus patient’s global assessment (r = 0.36), PhysMSK versus patient MSK (r = 0.39), and PhysSk versus patient skin (r = 0.49).Conclusion.PGA assessed by means of VAS is a reliable tool to assess MSK and dermatological disease activity. PGA may diverge from patient self-evaluation. Because MSK and skin/nail disease activity may diverge, it is suggested that both PhysMSK and PhysSk are assessed.


Rheumatology ◽  
2020 ◽  
Author(s):  
Augusta Ortolan ◽  
Sofia Ramiro ◽  
Floris van Gaalen ◽  
Tore K Kvien ◽  
Robert B M Landewe ◽  
...  

Abstract Objective To develop an alternative Ankylosing Spondylitis Disease Activity Score (ASDAS) to be used in research settings in axial SpA (axSpA) when Patient Global Assessment (PGA) is unavailable in databases. Methods Longitudinal data from four axSpA cohorts and two randomized controlled trials were combined. Observations were randomly split in a development (N = 1026) and a validation cohort (N = 1059). Substitutes of PGA by BASDAI total score, single or combined individual BASDAI questions, and a constant value, were established in the development cohort. Conversion factors for each substitute were defined by Generalized Estimating Equations, obtaining seven ‘alternative’ formulae. Validation was performed in the validation cohort according to the OMERACT filter, taking into consideration: (i) truth (agreement with original-ASDAS in the continuous score, by intraclass correlation coefficient and in disease activity states, by weighted kappa); (ii) discrimination [standardized mean difference of ASDAS scores between high/low disease activity states defined by external anchors, e.g. Patient Acceptable Symptom State; agreement (kappa) in the percentage of patients reaching ASDAS improvement criteria according to alternative vs original formulae]; and (iii) feasibility. Results Comparing various options, alternative-ASDAS using BASDAI total as PGA replacement proved to be: truthful (intraclass correlation coefficient = 0.98, kappa = 0.90), discriminative [ASDAS scores between Patient Acceptable Symptom State no/yes: standardized mean difference = 1.37 (original-ASDAS standardized mean difference = 1.43); agreement with original-ASDAS in major improvement/clinically important improvement criteria: kappa = 0.93/0.88] and feasible (BASDAI total often available, as questions required for the ASDAS; conversion coefficient ≈ 1). Conclusion Alternative-ASDAS using BASDAI total score as PGA replacement is the most truthful, discriminative and feasible instrument.


2011 ◽  
Vol 38 (5) ◽  
pp. 898-903 ◽  
Author(s):  
ALBERTO CAULI ◽  
DAFNA D. GLADMAN ◽  
ALESSANDRO MATHIEU ◽  
IGNAZIO OLIVIERI ◽  
GIOVANNI PORRU ◽  
...  

Objective.During OMERACT 8, delegates selected patient global assessment (PGA) of disease as a domain to be evaluated in randomized controlled trials in psoriatic arthritis (PsA). This study assessed the reliability of the PGA, measured by means of 0–100 mm visual analog scale (VAS), and the additional utility of separate VAS scales for joints (PJA) and skin (PSA).Methods.In total, 319 consecutive patients with PsA (186 men, 133 women, mean age 51 ± 13 yrs) were enrolled. PGA, PJA, and PSA were administered at enrolment (W0) and after 1 week (W1). Detailed clinical data, including ACR joint count, Psoriasis Area and Severity Index (PASI), and Hospital Anxiety and Depression Scale, were recorded.Results.Comparison of W0 and W1 scores showed no significant variations (intraclass correlation coefficients for PGA 0.87, PJA 0.86, PSA 0.78), demonstrating the reliability of the instrument. PGA scores were not influenced by patient anxiety or depression, but were dependent on PJA and PSA (p = 0.00001). PJA was dependent on the number of swollen and tender joints (p < 0.00001). PSA scores were influenced by the extent of skin psoriasis and by hand skin involvement (p = 0.00001). Joint and skin disease were found not to correlate in terms of disease activity as evidenced by the swollen joint count compared to PASI (r = 0.11) and by the PJA compared to PSA (r = 0.38).Conclusion.PGA assessed by means of VAS is a reliable tool related to joint and skin disease activity. Because joint and skin disease often diverge it is suggested that in some circumstances both PJA and PSA are also assessed.


2016 ◽  
Vol 17 (4) ◽  
pp. 294-299 ◽  
Author(s):  
Mohammad Y Hajeer ◽  
Ahmad L Maroua ◽  
Mowaffak Ajaj

ABSTRACT Objective To evaluate the accuracy and reproducibility of linear measurements made on cone-beam computed tomography (CBCT)-derived digital models. Materials and methods A total of 25 patients (44% female, 18.7 ± 4 years) who had CBCT images for diagnostic purposes were included. Plaster models were obtained and digital models were extracted from CBCT scans. Seven linear measurements from predetermined landmarks were measured and analyzed on plaster models and the corresponding digital models. The measurements included arch length and width at different sites. Paired t test and Bland–Altman analysis were used to evaluate the accuracy of measurements on digital models compared to the plaster models. Also, intraclass correlation coefficients (ICCs) were used to evaluate the reproducibility of the measurements in order to assess the intraobserver reliability. Results The statistical analysis showed significant differences on 5 out of 14 variables, and the mean differences ranged from −0.48 to 0.51 mm. The Bland–Altman analysis revealed that the mean difference between variables was (0.14 ± 0.56) and (0.05 ± 0.96) mm and limits of agreement between the two methods ranged from −1.2 to 0.96 and from −1.8 to 1.9 mm in the maxilla and the mandible, respectively. The intraobserver reliability values were determined for all 14 variables of two types of models separately. The mean ICC value for the plaster models was 0.984 (0.924–0.999), while it was 0.946 for the CBCT models (range from 0.850 to 0.985). Conclusion Linear measurements obtained from the CBCTderived models appeared to have a high level of accuracy and reproducibility. How to cite this article Maroua AL, Ajaj M, Hajeer MY. The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models. J Contemp Dent Pract 2016;17(4):294-299.


2017 ◽  
Vol 45 (1) ◽  
pp. 70-77 ◽  
Author(s):  
Pernille Hededal ◽  
Mikkel Østergaard ◽  
Inge Juul Sørensen ◽  
Anne Gitte Loft ◽  
Jens S. Hindrup ◽  
...  

Objective.To develop semiaxial magnetic resonance imaging (MRI) scoring methods for assessment of sacroiliac joint (SIJ) bone marrow edema (BME) in patients with axial spondyloarthritis, and to compare the reliability with equivalent semicoronal scoring methods.Methods.Two semiaxial SIJ MRI scoring methods were developed based on the principles of the semicoronal Berlin and Spondyloarthritis Research Consortium of Canada (SPARCC) methods. A global quadrant-based method was also developed. Baseline and 12-week MRI of the SIJ from 51 patients participating in a randomized double-blind placebo-controlled trial of adalimumab 40 mg every other week versus placebo were scored by the semiaxial and the corresponding semicoronal methods. Results were compared by linear regression analysis. The reproducibility and sensitivity were evaluated by intraclass correlation coefficients (ICC) and smallest detectable change [SDC, absolute values and percentage of the highest observed score (SDC-HOS)].Results.Interreader and intrareader ICC were moderate to very high for semiaxial scoring methods (baseline 0.83–0.88 and 0.85–0.97; change 0.33–0.78), while high to very high for semicoronal scoring methods (baseline 0.90–0.92 and 0.93–0.97; change 0.77–0.89). Association between semiaxial and semicoronal scores were high for both the Berlin and SPARCC method (baseline: R2 = 0.93 and 0.88; change: R2 = 0.82 and 0.87, respectively), while lower for the global method (baseline: R2 = 0.79; change: R2 = 0.54). The SDC-HOS were 9.8–18.6% and 5.9–10.7% for the semiaxial and semicoronal methods, respectively.Conclusion.Detection of SIJ BME in the semiaxial scan plane is feasible and reproducible. However, a slightly lower reliability of all 3 semiaxial methods supports the general practice of using the coronal scan-plane in therapeutic studies.


2020 ◽  
Vol 18 (2) ◽  
Author(s):  
Noorshazana Mat Rejab @ Md Rejab ◽  
Mohd Radzi Hilmi ◽  
Khairidzan Mohd Kamal ◽  
Md Muziman Syah Md Mustafa

Introduction: Accurate corneal wavefront aberration measurements are essential in determining patient’s suitability, vision outcomes and patient satisfaction in laser refractive surgeries. This study aimed to evaluate the reliability measurement of higher-order aberration (HOA) using corneal videokeratograph Atlas 9000. Materials and method:  38 eyes of 19 participants were recruited in this study. Comprehensive eye examination was done to ensure all participants eligibility, and any conditions in which obstruct the central cornea were excluded. Corneal wavefront aberrations were measured based on Zernike polynomials. In assessing repeatability, three repetitive measurements in five minutes in a single session were taken by 2 experience examiners. For reproducibility measurement, similar approach was done with the time-interval between measurements was set at one week. Bland-Altman, limits of agreement (LoA) and intraclass correlation coefficients (ICCs) were used to evaluate the reliability measurement. Results: Bland-Altman and LoA findings revealed no significant differences for both repeatability and reproducibility measurement. For repeatability testing, the mean differences for vertical trefoil, oblique trefoil and spherical aberration were -0.096 ± 0.493, 0.001 ± 0.048, 0.008 ± 0.035, 0.004 ± 0.029, 0.010 ± 0.053 with LoA of 1.930, 0.188, 0.138, 0.114, and 0.208 respectively. Intraclass correlation coefficient (ICC) excellent reliability of 0.841 for all parameters. Likewise, reproducibility  testing showed similar findings  with the mean difference were -0.018 ± 0.091, 0.016 ± 0.061, -0.0004 ± 0.036, -0.002 ± 0.042, 0.003 ± 0.026, with LoA of 0.356, 0.24, 0.141,0.164, and 0.102 respectively. Intraclass correlation coefficient (ICC) shows excellent reliability of more than 0.9 for all parameters. LoA of less than 1.0 were observed in all measurements (except for repeatability of vertical trefoil) indicates high consistency of the measurements. Conclusions: Corneal videokeratograph Atlas 9000 provides excellent HOA measurement reliability.


2020 ◽  
Vol 33 (6) ◽  
pp. 783-791
Author(s):  
Yusuke Yokota ◽  
Tomohisa Okada ◽  
Yasutaka Fushimi ◽  
Akira Yamamoto ◽  
Satoshi Nakajima ◽  
...  

Abstract Objective To compare the absolute values and repeatability of magnetic resonance fingerprinting (MRF) with 3000 and 1500 echoes/slice acquired in 41 s and 20 s (MRF3k and MRF1.5k, respectively). Materials and methods MRF3k and MRF1.5k scans based on fast imaging with steady precession (FISP) were conducted using a 3 T scanner. Inter-scan agreement and intra-scan repeatability were investigated in 41 and 28 subjects, respectively. Region-of-interest (ROI) analysis was conducted on T1 values of MRF3k by two raters, and their agreement was evaluated using intraclass correlation coefficients (ICCs). Between MRF3k and MRF1.5k, differences in T1 and T2 values and inter-measurement correlation coefficients (CCs) were investigated. Intra-measurement repeatability was evaluated using coefficients of variation (CVs). A p value < 0.05 was considered statistically significant. Results The ICCs of ROI measurements were 0.77–0.96. Differences were observed between the two MRF scans, but the CCs of the overall ROIs were 0.99 and 0.97 for the T1 and T2 values, respectively. The mean and median CVs of repeatability were equal to or less than 1.58% and 3.13% in each of the ROIs for T1 and T2, respectively; there were some significant differences between MRF3k and MRF1.5k, but they were small, measuring less than 1%. Discussion Both MRF3k and MRF1.5k had high repeatability, and a strong to very strong correlation was observed, with a trend toward slightly higher values in MRF1.5k.


Sign in / Sign up

Export Citation Format

Share Document