Direct Detection of Red Blood Cell Fragments: A New Flow Cytometric Method to Evaluate Hemolysis in Blood Pumps

ASAIO Journal ◽  
2001 ◽  
Vol 47 (5) ◽  
pp. 533-536 ◽  
Author(s):  
Joerg Linneweber ◽  
Thomas W. Chow ◽  
Tamaki Takano ◽  
Tomohiru Maeda ◽  
Kenji Nonaka ◽  
...  
ASAIO Journal ◽  
2000 ◽  
Vol 46 (2) ◽  
pp. 182
Author(s):  
J. Linneweber ◽  
T. Chow ◽  
T. Takano ◽  
T. Maeda ◽  
K. Nonaka ◽  
...  

Blood ◽  
1999 ◽  
Vol 94 (9) ◽  
pp. 3037-3047 ◽  
Author(s):  
Jack Levin ◽  
Jin-Peng Peng ◽  
Georgiann R. Baker ◽  
Jean-Luc Villeval ◽  
Patrick Lecine ◽  
...  

Abstract Expression of the p45 subunit of transcription factor NF-E2 is restricted to selected blood cell lineages, including megakaryocytes and developing erythrocytes. Mice lacking p45 NF-E2 show profound thrombocytopenia, resulting from a late arrest in megakaryocyte differentiation, and a number of red blood cell defects, including anisocytosis and hypochromia. Here we report results of studies aimed to explore the pathophysiology of these abnormalities. Mice lacking NF-E2 produce very few platelet-like particles that display highly disorganized ultrastructure and respond poorly to platelet agonists, features consistent with the usually lethal hemorrhage in these animals. Thrombocytopenia was evident during fetal life and was not corrected by splenectomy in adults. Surprisingly, fetal NF-E2–deficient megakaryocyte progenitors showed reduced proliferation potential in vitro. Thus, NF-E2 is required for regulated megakaryocyte growth as well as for differentiation into platelets. All the erythroid abnormalities were reproduced in lethally irradiated wild-type recipients of hematopoietic cells derived from NF-E2-null fetuses. Whole blood from mice lacking p45 NF-E2 showed numerous small red blood cell fragments; however, survival of intact erythrocytes in vivo was indistinguishable from control mice. Considered together, these observations indicate a requirement for NF-E2 in generating normal erythrocytes. Despite impressive splenomegaly at baseline, mice lacking p45 NF-E2 survived splenectomy, which resulted in increased reticulocyte numbers. This reveals considerable erythroid reserve within extra-splenic sites of hematopoiesis and suggests a role for the spleen in clearing abnormal erythrocytes. Our findings address distinct aspects of the requirements for NF-E2 in blood cell homeostasis and establish its roles in proper differentiation of megakaryocytes and erythrocytes.


2001 ◽  
Vol 56 (9-10) ◽  
pp. 857-864 ◽  
Author(s):  
Federico Bordi ◽  
Cesare Cametti ◽  
Francesco De Luca ◽  
Tommaso Gili ◽  
Roberta Misasi ◽  
...  

AbstractAlterations in the electrical passive parameters of red blood cell membranes occurring during storage have been investigated by means of two different experimental approaches, i.e., radiowave dielectric spectroscopy measurements and flow-cytometric measurements. We observed a correlation between the appearance of phosphatidylserine molecules in the outer leaflet of the cell membrane and the occurrence of a change in the electrical passive membrane parameters. The electrical re-organization of the membrane, resulting in an increase of its conductivity and permittivity after 5 -7 days from blood storage, can be considered as a precursory event for the loss of asymmetry in the lipid distribution across red blood cell membrane.


2007 ◽  
Vol 14 (9) ◽  
pp. 1165-1172 ◽  
Author(s):  
John Ferbas ◽  
John Thomas ◽  
John Hodgson ◽  
Amitabh Gaur ◽  
Nicole Casadevall ◽  
...  

ABSTRACT Immunogenicity profiles of recombinant therapeutic proteins are important to understand because antibodies raised against these molecules may have important clinical sequelae. The purpose of the present study was to demonstrate that a flow cytometric bead array could be used to detect clinically relevant antibodies with specificity to such therapeutics. We chose to evaluate well-characterized specimens from persons treated with epoetin alfa that developed antibody-mediated pure red blood cell aplasia as a means to demonstrate the utility of this platform. Our data show that this assay is capable of detecting anti-epoetin alfa antibodies with a relative antibody concentration of 50 ng/ml, where 25 of 25 sera spiked with antibodies at this concentration scored positive. Moreover, the assay was designed to include positive and negative control beads for each specimen that is processed to ensure the specificity of the signal when detected. Measurement of interassay precision supports quantitative estimates of relative antibody concentrations in the range of 313 to 5,000 ng/ml, where the percent coefficient of variation did not exceed 20%. With respect to clinical specimens, antibodies with specificity for epoetin alfa could be easily detected in a set of specimens from persons with pure red blood cell aplasia that had prior exposure to the EPREX brand of recombinant epoetin alfa. Further development and validation of this approach may facilitate successful widespread application of the method for detection of anti-epoetin alfa antibodies, as well as antibodies directed against other recombinant therapeutic proteins.


Blood ◽  
1999 ◽  
Vol 94 (9) ◽  
pp. 3037-3047 ◽  
Author(s):  
Jack Levin ◽  
Jin-Peng Peng ◽  
Georgiann R. Baker ◽  
Jean-Luc Villeval ◽  
Patrick Lecine ◽  
...  

Expression of the p45 subunit of transcription factor NF-E2 is restricted to selected blood cell lineages, including megakaryocytes and developing erythrocytes. Mice lacking p45 NF-E2 show profound thrombocytopenia, resulting from a late arrest in megakaryocyte differentiation, and a number of red blood cell defects, including anisocytosis and hypochromia. Here we report results of studies aimed to explore the pathophysiology of these abnormalities. Mice lacking NF-E2 produce very few platelet-like particles that display highly disorganized ultrastructure and respond poorly to platelet agonists, features consistent with the usually lethal hemorrhage in these animals. Thrombocytopenia was evident during fetal life and was not corrected by splenectomy in adults. Surprisingly, fetal NF-E2–deficient megakaryocyte progenitors showed reduced proliferation potential in vitro. Thus, NF-E2 is required for regulated megakaryocyte growth as well as for differentiation into platelets. All the erythroid abnormalities were reproduced in lethally irradiated wild-type recipients of hematopoietic cells derived from NF-E2-null fetuses. Whole blood from mice lacking p45 NF-E2 showed numerous small red blood cell fragments; however, survival of intact erythrocytes in vivo was indistinguishable from control mice. Considered together, these observations indicate a requirement for NF-E2 in generating normal erythrocytes. Despite impressive splenomegaly at baseline, mice lacking p45 NF-E2 survived splenectomy, which resulted in increased reticulocyte numbers. This reveals considerable erythroid reserve within extra-splenic sites of hematopoiesis and suggests a role for the spleen in clearing abnormal erythrocytes. Our findings address distinct aspects of the requirements for NF-E2 in blood cell homeostasis and establish its roles in proper differentiation of megakaryocytes and erythrocytes.


Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 4727-4727
Author(s):  
Guat Bee Tan ◽  
Christina Sum ◽  
Ponnudurai Kuperan

Abstract Abstract 4727 The examination of blood films by microscopy remains one of the major labour intensive procedures in the laboratory and the challenge is to reduce the number of blood films examined without missing important diagnostic information. Automated blood cell counters offer a leucocyte count, red cell and platelet count and five-part (some 6-part) leucocyte differential. Haematology instrument differentials provide only limited information on cell morphology using abnormal cell flags and are often unable to reliably classify abnormal and immature cells. The examination of blood films is not only time consuming, it also requires highly trained staff. The impact of a wrong diagnosis necessitates that experienced staff are present in the laboratory 24 hours a day. Furthermore, manual cell classification is subjective, with significant inter and intra observer variation (Koepke et al. 1985) and is also subject to significant statistical variance (Rumke 1985). There have recently been several reports of using monoclonal antibody cocktails for an extended leucocyte differential by flow cytometry (Faucher et al. 2007, Roussel et al. 2010). The aim of this study was to compare a flow cytometric method for the white blood cell differential with the automated count from the Beckman Coulter LH750 haematology analyser and the reference manual microscopic 2 × 200 cell count (CLSI H20-A2). Cell morphology was also assessed microscopically for the presence of cells such as reactive or abnormal lymphocytes or blasts. The flow cytometric method, described by Faucher et al. 2007, uses 6 antibodies (CD45, CD36, CD2, CD294, CD19 and CD16) premixed in a single tube. The protocol allows detection of all white blood cells, mature neutrophils, total lymphocytes, total monocytes, eosinophils, basophils, immature granulocytes, B lymphocytes, non-cytotoxic T-lymphocytes, cytotoxic T/NK lymphocytes, CD16 positive and CD16 negative monocytes, and blasts cells with lineage orientation. A 5-colour flow cytometer, the Beckman Coulter FC500, was used for analysis. The gating strategy described by Faucher et al. (2007) was used. EDTA blood was analysed on 27 normal samples and 148 abnormal samples which demonstrated abnormal cell flags on the LH750. These samples included the presence of blast cells, immature granulocytes and abnormal lymphocytes. Results for most cell populations measured by the flow cytometric differential compared well with both the LH750 automated differential and the manual reference method. Comparative results using Pearson correlation show that the automated LH750 differential produced r values of greater than 0.94 for neutrophils, lymphocytes and eosinophils. The manual reference method produced r values of greater than 0.89 for neutrophils, lymphocytes and eosinophils. Results for flow cytometric monocytes compared to the LH750 and manual differential gave an r value of 0.84 and 0.87 respectively. Results for basophils were significantly better when the flow cytometric method was compared to the LH750 rather than the manual method, r = 0.68 for flow cytometry versus LH750 and r = 0.43 for flow cytometry versus manual method. The value of the manual differential is diminished because of the low number of cells counted; the precision is not good for smaller cell populations (Hübl et al. 1995). Very good correlation of blast cells, r = 0.98 and immature granulocytes, r = 0.92 was seen between the manual and flow cytometric method. The flow cytometric differential is superior to the microscopic method since it is objective and due to the higher number of cells counted, it can detect subpopulations of cells that are present in smaller number with greater statistical and interpretive confidence. More importantly, it recognises and quantitates morphologically abnormal cells such as reactive lymphocytes, inflammatory monocytes and the lineage of blast cells. However, the examination of blood cell morphology by microscopy still has an important role in the diagnosis of diseases. Disclosures: No relevant conflicts of interest to declare.


Sign in / Sign up

Export Citation Format

Share Document