A Whole-Body Registration-Free Navigation System for Image-Guided Surgery and Interventional Radiology

2000 ◽  
Vol 35 (5) ◽  
pp. 279-288 ◽  
Author(s):  
AUGUSTINUS LUDWIG JACOB ◽  
PETER MESSMER ◽  
ACHIM KAIM ◽  
NORBERT SUHM ◽  
PIETRO REGAZZONI ◽  
...  
2021 ◽  
pp. 155633162110298
Author(s):  
Jessica Dorilio ◽  
Nicole Utah ◽  
Christina Dowe ◽  
Fedan Avrumova ◽  
Daniel Alicea ◽  
...  

Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.


2019 ◽  
Vol 19 (9) ◽  
pp. S59
Author(s):  
Antonio T. Brecevich ◽  
Christina Dowe ◽  
Darren R. Lebl ◽  
Andrew A. Sama ◽  
Celeste Abjornson ◽  
...  

Author(s):  
Alessandro De Mauro ◽  
Julien Mazars ◽  
Luigi Manco ◽  
Taulent Mataj ◽  
Alberto Hernandez Fernandez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document