Emergency Transport of AS-1 Red Cell Units by Pneumatic Tube System

1990 ◽  
Vol 30 (3) ◽  
pp. 346-348 ◽  
Author(s):  
G HARDIN ◽  
GARY QUICK ◽  
DANIEL J. LADD
2015 ◽  
Vol 9 (2) ◽  
pp. 195 ◽  
Author(s):  
Sabita Basu ◽  
Subhosmito Chakraborty ◽  
Subir Sinha ◽  
Supriya Dhar

2018 ◽  
Vol 2018 ◽  
pp. 1-4 ◽  
Author(s):  
Devi Subbarayan ◽  
Chidambharam Choccalingam ◽  
Chittode Kodumudi Anantha Lakshmi

Background. Automation helps improve laboratory operational efficiency and reduce the turnaround time. Pneumatic tube systems (PTS) automate specimen transport between the lab and other areas of the hospital. Its effect on complete blood count (CBC) and coagulation is still controversial.Aim. To study the effects of pneumatic tube system sample transport on complete blood count and coagulation parameters to compare them with hand delivered samples.Methods. 75 paired samples for complete blood count and 25 paired samples for coagulation analysis were compared between samples sent via pneumatic tube system and hand delivered system.Results. PTS showed significant decrease in red cell indices such as MCV and RDW and increase in MCHC. Other red cell parameters and WBC parameters showed no statistical significant difference. Statistically significant increase in platelet count was observed with PTS samples. However, these differences were clinically insignificant. No significant effect of PTS was found in PT and APTT samples compared to the hand delivered samples.Conclusion. Despite statistically significant changes in RBC parameters such as MCV, RDW, and MCHC and platelet count, these changes were clinically insignificant. Hence, blood samples for CBC and coagulation assay can safely be transported via our hospital’s PTS. However, further studies on platelet count are warranted to ensure safe transport and accuracy of the results.


2017 ◽  
Vol 158 ◽  
pp. 35-37
Author(s):  
Aurélien Lebreton ◽  
Alessandro Casini ◽  
Oana Bulla ◽  
Pierre Fontana

2013 ◽  
pp. 206-210 ◽  
Author(s):  
Fatma Emel Koçak ◽  
Mustafa Yöntem ◽  
Özlem Yücel ◽  
Mustafa Çilo ◽  
Özlem Genç ◽  
...  

2007 ◽  
Vol 131 (2) ◽  
pp. 293-296
Author(s):  
Alexander Kratz ◽  
Raneem O. Salem ◽  
Elizabeth M. Van Cott

Abstract Context.—Technologic advances affecting analyzers used in clinical laboratories have changed the methods used to obtain many laboratory measurements, and many novel parameters are now available. The effects of specimen transport through a pneumatic tube system on laboratory results obtained with such modern instruments are unclear. Objective.—To determine the effects of sample transport through a pneumatic tube system on routine and novel hematology and coagulation parameters obtained on state-of-the-art analyzers. Design.—Paired blood samples from 33 healthy volunteers were either hand delivered to the clinical laboratory or transported through a pneumatic tube system. Results.—No statistically significant differences were observed for routine complete blood cell count and white cell differential parameters or markers of platelet activation, such as the mean platelet component, or of red cell fragmentation. When 2 donors who reported aspirin intake were excluded from the analysis, there was a statistically, but not clinically, significant impact of transport through the pneumatic tube system on the mean platelet component. There were no statistically significant differences for prothrombin time, activated partial thromboplastin time, waveform slopes for prothrombin time or activated partial thromboplastin time, fibrinogen, or fibrin monomers. Conclusions.—Although further study regarding the mean platelet component may be required, transport through a pneumatic tube system has no clinically significant effect on hematology and coagulation results obtained with certain modern instruments in blood samples from healthy volunteers.


2012 ◽  
Vol 47 (1) ◽  
pp. 81-83 ◽  
Author(s):  
Ismail Sari ◽  
Aliriza Arslan ◽  
Can Ozlu ◽  
Sibel Hacioglu ◽  
Mehmet Hilmi Dogu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document