Effect of Modified Japanese Orthopedic Association Severity Classifications on Satisfaction With Outcomes 12 Months After Elective Surgery for Cervical Spine Myelopathy

Spine ◽  
2019 ◽  
Vol 44 (11) ◽  
pp. 801-808
Author(s):  
Anthony L. Asher ◽  
Clinton J. Devin ◽  
Benjamin M. Weisenthal ◽  
Jacquelyn Pennings ◽  
Inamullah Khan ◽  
...  
Neurosurgery ◽  
2003 ◽  
Vol 52 (5) ◽  
pp. 1081-1088 ◽  
Author(s):  
John K. Houten ◽  
Paul R. Cooper

Abstract OBJECTIVE Multilevel anterior decompressive procedures for cervical spondylotic myelopathy or ossification of the posterior longitudinal ligament may be associated with a high incidence of neurological morbidity, construct failure, and pseudoarthrosis. We theorized that laminectomy and stabilization of the cervical spine with lateral mass plates would obviate the disadvantages of anterior decompression, prevent the development of kyphotic deformity frequently seen after uninstrumented laminectomy, decompress the spinal cord, and produce neurological results equal or superior to those achieved by multilevel anterior procedures. METHODS We retrospectively reviewed the records of 38 patients who underwent laminectomy and lateral mass plating for cervical spondylotic myelopathy or ossification of the posterior longitudinal ligament between January 1994 and November 2001. Seventy-six percent of patients had spondylosis, 18% had ossification of the posterior longitudinal ligament, and 5% had both. Clinical presentation included upper extremity sensory complaints (89%), gait difficulty (70%), and hand use deterioration (67%). Spasticity was present in 83%, and weakness of one or more muscle groups was seen in 79%. Spinal cord signal abnormality on sagittal T2-weighted magnetic resonance imaging (MRI) was seen in 68%. Neurological evaluation was performed using a modification of the Japanese Orthopedic Association Scale for functional assessment of myelopathy, the Cooper Scale for separate evaluation of upper and lower extremity motor function, and a five-point scale for evaluation of strength in individual muscle groups. Lateral cervical spine x-rays were analyzed using a curvature index to determine maintenance of alignment. Each surgically decompressed level was graded on a four-point scale using axial MRI to assess the adequacy of decompression. Late follow-up was conducted by telephone interview. RESULTS Laminectomy was performed at a mean 4.6 levels. Follow-up was obtained at a mean of 30.2 months after the procedure. The score on the modified Japanese Orthopedic Association scale improved in 97% of patients from a mean of 12.9 preoperatively to 15.58 postoperatively (P< 0.0001). In the upper extremities, function measured by the Cooper Scale improved from 1.8 to 0.7 (P< 0.0001), and in the lower extremities, function improved from 1.0 to 0.4 (P< 0.0002). There was a statistically significant improvement in strength in the triceps (P< 0.0001), iliopsoas (P< 0.0002), and hand intrinsic muscles (P< 0.0001). X-rays obtained at a mean of 5.9 months after surgery revealed no change in spinal alignment as measured by the curvature index. There was a decrease in the mean preoperative compression grade from 2.46 preoperatively to 0.16 postoperatively (P< 0.0001). There was no correlation between neurological outcome and the presence of spinal cord signal change on T2-weighted MRI scans, patient age, duration of symptoms, or preoperative medical comorbidity. CONCLUSION Multilevel laminectomy and instrumentation with lateral mass plates is associated with minimal morbidity, provides excellent decompression of the spinal cord (as visualized on MRI), produces immediate stability of the cervical spine, prevents kyphotic deformity, and precludes further development of spondylosis at fused levels. Neurological outcome is equal or superior to multilevel anterior procedures and prevents spinal deformity associated with laminoplasty or noninstrumented laminectomy.


Author(s):  
Piyawat Bintachitt ◽  
Ratanaphorn Chamnan ◽  
Weera Chaiyamongkol ◽  
Wongthawat Liawrungrueawng

     A Civilian gunshot wound associated with metallosis in the cervical spine region was an extremely rare case; hence, the clinician had difficulty with diagnosis and surgical treatment.      A 57–year-old gentleman had a history of a gunshot wound injury going back 30 years. He presented with neck pain, progress of paresthesia of upper extremities and progressively difficult ambulation for 3 months. Radiographic and pathological diagnosis from tissue of the 7th paravertebral of the cervical spine showed foreign bodies consistent with metallosis. The patient showed improvement of symptoms after posterior cervical spine fixation and decompression. He had full recovery at 1 year follow up.      Metallosis can occur in cases of chronic exposure to lead and metals. The results of this chronic process of metallosis will develop to metalloma, which then compresses the spinal cord and develops into myelopathy. The patient had a bullet, or piece of metal at the cervical spine, so surgical removal was performed to prevent further compression of the spinal cord from metalloma.


2018 ◽  
Vol 7 (12) ◽  
pp. 469 ◽  
Author(s):  
Paul Oni ◽  
Rolf Schultheiß ◽  
Kai-Michael Scheufler ◽  
Jakob Roberg ◽  
Ali Harati

Background: Multilevel anterior cervical decompression and fixation of four and more levels is a common surgical procedure used for several diseases. Methods: We reviewed the radiological and clinical outcomes after anterior cervical discectomy or corpectomy and fixation of four and more levels in 85 patients (55 men and 30 women) with an average age of 59.6 years. Surgical indication was multilevel cervical degenerative myelopathy and radiculopathy in 72 (85%) patients, multilevel cervical spondylodiscitis in four (5%), complex traumatic cervical fractures in four (5%), metastatic cervical spine tumor in two (2%), and ossification of the posterior longitudinal ligament in three (3%) patients. Results: There were no severe intraoperative complications such as spinal cord or vertebral artery injury or dissection. Seventy-three patients had four, 10 patients had five, and two patients had six anterior cervical level fixations. The visual analog scale (VAS) and Japanese Orthopedic Association (mJOA) scale scores improved (6.9 to 1.3 (p < 0.001) and 13.9 to 16.5 (p < 0.001), respectively). The Cobb angle increased from 5.7° to 17.6° postoperatively (p < 0.001). Secondary posterior fixation was necessary in three cases due to pseudarthrosis. Conclusion: The anterior approach appears to be optimal for ventral compressive pathology and lordosis restoration to the cervical spine. Limitations of multiple level decompression and fixation included increasing pseudoarthrosis rates, especially after corpectomy, and increasing fused level numbers.


2014 ◽  
Vol 121 (2) ◽  
pp. 260-271 ◽  
Author(s):  
Bradley J. Hindman ◽  
Brandon G. Santoni ◽  
Christian M. Puttlitz ◽  
Robert P. From ◽  
Michael M. Todd

Abstract Introduction: Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two laryngoscopes hypothesized to differ in force. Methods: Fourteen adults undergoing elective surgery were intubated twice (Macintosh, Airtraq). During each intubation, laryngoscope force, cervical spine motion, and glottic view were recorded. Force and motion were referenced to a preintubation baseline (stage 1) and were characterized at three stages: stage 2 (laryngoscope introduction); stage 3 (best glottic view); and stage 4 (endotracheal tube in trachea). Results: Maximal force and motion occurred at stage 3 and differed between the Macintosh and Airtraq: (1) force: 48.8 ± 15.8 versus 10.4 ± 2.8 N, respectively, P = 0.0001; (2) occiput-C5 extension: 29.5 ± 8.5 versus 19.1 ± 8.7 degrees, respectively, P = 0.0023. Between stages 2 and 3, the motion/force ratio differed between Macintosh and Airtraq: 0.5 ± 0.2 versus 2.0 ± 1.4 degrees/N, respectively; P = 0.0006. Discussion: The relationship between laryngoscope force and cervical spine motion is: (1) nonlinear and (2) differs between laryngoscopes. Differences between laryngoscopes in motion/force relationships are likely due to: (1) laryngoscope-specific cervical extension needed for intubation, (2) laryngoscope-specific airway displacement/deformation needed for intubation, and (3) cervical spine and airway tissue viscoelastic properties. Cervical spine motion during endotracheal intubation is not directly proportional to force. Low-force laryngoscopes cannot be assumed to result in proportionally low cervical spine motion.


2020 ◽  
Vol 02 (02) ◽  
Author(s):  
Truc Tam Vu ◽  
Hanh The Nguyen ◽  
Riet Ngoc Do ◽  
Thanh Dang Le ◽  
Vien Chi Tieu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document