scholarly journals Heparin-Induced Thrombocytopenia

2022 ◽  
Vol 45 (1) ◽  
pp. 2-7
Author(s):  
Raymond Smith ◽  
Zackery Bullard
2000 ◽  
Vol 10 (4) ◽  
pp. 323-324 ◽  
Author(s):  
F. Araujo ◽  
J. J. Sa ◽  
V. Araujo ◽  
M. Lopes ◽  
L. M. Cunha-Ribeiro

VASA ◽  
2020 ◽  
pp. 1-6 ◽  
Author(s):  
Marina Di Pilla ◽  
Stefano Barco ◽  
Clara Sacco ◽  
Giovanni Barosi ◽  
Corrado Lodigiani

Summary: A 49-year-old man was diagnosed with pre-fibrotic myelofibrosis after acute left lower-limb ischemia requiring amputation and portal vein thrombosis. After surgery he developed heparin-induced thrombocytopenia (HIT) with venous thromboembolism, successfully treated with argatroban followed by dabigatran. Our systematic review of the literature supports the use of dabigatran for suspected HIT.


1994 ◽  
Vol 72 (05) ◽  
pp. 783-784 ◽  
Author(s):  
Y Cadroy ◽  
J Amiral ◽  
H Raynaud ◽  
P Brunel ◽  
A Mazaleyrat ◽  
...  

1993 ◽  
Vol 69 (04) ◽  
pp. 344-350 ◽  
Author(s):  
B H Chong ◽  
J Burgess ◽  
F Ismail

SummaryThe platelet aggregation test is widely used for the diagnosis of heparin-induced thrombocytopenia (HIT), a potentially serious complication of heparin therapy. We have evaluated its sensitivity and specificity in comparison with those of the 14C-serotonin release test. The sensitivity of the platelet aggregation test was found to vary with the heparin concentration and the donor of the platelets used in the test. The optimal heparin concentrations were between 0.1 and 1.0 U/ml. Using these heparin concentrations, the mean sensitivity varied from 39% (with the least reactive platelets) to 81% (with the most reactive platelets). In comparison, the sensitivity of the release test ranged from 65% to 94%. The specificities of the platelet aggregation test were 82%, 90% and 100% for the following control groups: (1) non-thrombocytopenic patients given heparin, (2) patients with thrombocytopenia due to other causes, and (3) normal controls not given heparin, respectively. The corresponding specificities for the release test was 94%, 90% and 100%. The specificities can be further increased to 100% for all controls with the adoption of a two-point system which defines a positive result as one in which platelet aggregation occurs with a low heparin concentration (0.5 U/ml) but not with 100 U heparin/ml. For optimal results, a two-point platelet aggregation test should be performed with heparin concentrations of 0.5 and 100 U/ml and using platelets of more reactive donors.


Sign in / Sign up

Export Citation Format

Share Document