The right supraclavicular ultrasound view for real-time ultrasound-guided definite placement of a central venous catheter with a microconvex transducer

2014 ◽  
Vol 31 (3) ◽  
pp. 173-174 ◽  
Author(s):  
Stefan U. Weber ◽  
Se-Chan Kim
2018 ◽  
Vol 19 (6) ◽  
pp. 528-534 ◽  
Author(s):  
Folkert Steinhagen ◽  
Maximilian Kanthak ◽  
Guido Kukuk ◽  
Christian Bode ◽  
Andreas Hoeft ◽  
...  

Introduction: A significant increase of the p-wave of a real-time intracavitary electrocardiography is a reliable and safe method to confirm the central venous catheter tip position close to the atrium. However, conflicting data about the feasibility of electrocardiography exist in patients with atrial fibrillation. Methods: An observational prospective case–control cohort study was set up to study the feasibility and accuracy of the electrocardiography-controlled central venous catheter tip placement in 13 patients with atrial fibrillation versus 10 patients with sinus rhythm scheduled for elective surgery. Each intervention was crosschecked with ultrasound-guided positioning via right supraclavicular fossa view and chest radiography. Ultrasound-guided supraclavicular venipuncture of the right subclavian vein and guidewire advancement were performed. A B-mode view of the superior vena cava and the right pulmonary artery was obtained to visualize the J-tip of the guidewire. The central venous catheter was advanced over the guidewire and the electrocardiography was derived from the J-tip of the guidewire protruding from the central venous catheter tip. Electrocardiography was read for increased p- and atrial fibrillation waves, respectively, and insertion depth was compared with the ultrasound method. Results: Electrocardiography indicated significantly increasing fibrillation and p-waves, respectively, in all patients and ultrasound-guided central venous catheter positioning confirmed a tip position within the lower third of the superior vena cava. Conclusion: Electrocardiography-guided central venous catheter tip positioning is a feasible real-time method for patients with atrial fibrillation. Combined with ultrasound, the electrocardiography-controlled central venous catheter placement may eliminate the need for postinterventional radiation exposure.


2016 ◽  
Vol 17 (5) ◽  
pp. 435-439 ◽  
Author(s):  
Se-Chan Kim ◽  
Ingo Gräff ◽  
Alexandra Sommer ◽  
Andreas Hoeft ◽  
Stefan Weber

2011 ◽  
Vol 112 (2) ◽  
pp. 378-381 ◽  
Author(s):  
Myles Dowling ◽  
Hatem A. Jlala ◽  
Jonathan G. Hardman ◽  
Nigel M. Bedforth

1993 ◽  
Vol 161 (4) ◽  
pp. 908-908 ◽  
Author(s):  
M Kontrus ◽  
M L Pretterklieber ◽  
M T Farres

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Haruka Yoshida ◽  
Shinichiro Ikemoto ◽  
Yasuyuki Tokinaga ◽  
Kanako Ejiri ◽  
Tomoyuki Kawamata

Abstract Background Cannulation of a central venous catheter is sometimes associated with serious complications. When arterial cannulation occurs, attention must be given to removal of a catheter. Case presentation A 62-year-old man was planned for emergency thoracic endovascular aortic repair. After the induction of anesthesia, a central venous catheter was unintentionally inserted into the right subclavian artery. We planned to remove the catheter. Since we considered that surgical repair would be highly invasive for the patient, we decided to remove it using a percutaneous intravascular stent. A stent was inserted through the right axillary artery. The stent was expanded immediately after the catheter was removed. Post-procedural angiography revealed no leakage from the catheter insertion site and no occlusion of the right subclavian and vertebral arteries. There were no obvious hematoma or thrombotic complications. Conclusions A catheter that has been misplaced into the right subclavian artery was safely removed using an intravascular stent.


2018 ◽  
Vol 2 (3) ◽  
pp. 277-281
Author(s):  
Lalit Kumar Rajbanshi ◽  
Sambhu Bahadur Karki ◽  
Batsalya Arjyal

Introduction: Central venous catheterization is a routine procedure for long-term infusion therapy and central venous pressure measurement. Sometimes, the catheter tip may be unintentionally placed at the position other than the junction of superior vena cava and right atrium. This is called malposition and can lead to erroneous pressure measurement, increase risk of thrombosis, venous obstruction or other life threatening complications like pneumothorax, cardiac temponade.Objectives: This study aimed to observe the incidence of the malposition and compare the same between ultrasound guided catheterization and blind anatomical landmark technique.Methodology: This study was a prospective comparative study conducted at the intensive care unit of Birat Medical College and Teaching Hospital for two-year duration. All the catheterizations were done either with the use of real time ultrasound or blind anatomical landmark technique. The total numbers of central venous catheterization, the total incidences of malposition were observed. Finally the incidences were compared between real time ultrasound guided technique and blind anatomical landmark technique.Results: In two-year duration of the study, a total of 422 central venous cannulations were successfully done. The real time ultrasound was used for 280 cannulations while blind anatomical landmark technique was used for 162 patients. The study observed various malposition in 36 cases (8.5%). The most common malposition was observed for subclavian vein to ipsilateral internal jugular vein (33.3%) followed by subclavian to subclavian vein (27.8%) and internal jugular to ipsilateral subclavian vein (16.7%). In four patients the catheter had a reverse course in the internal jugular vein while the tip was placed in pleural cavity in three cannulations. There was coiling of the catheter inside left subclavian vein in one patient. The malposition was significantly reduced with the use of the real time ultrasound (P< 0.001). However there is no significant difference in the incidence of the various malposition between ultrasound guidance technique and blind anatomical landmark technique when compared individually.Conclusion: The malposition of the central venous catheter tip was common complication with the overall incidence of 8.5%. The most common malposition was subclavian vein to internal jugular vein. The use of real time ultrasound during the catheterization procedure can significantly reduced the risk of malposition.Birat Journal of Health SciencesVol.2/No.3/Issue 4/Sep- Dec 2017, Page: 277-281


Sign in / Sign up

Export Citation Format

Share Document