Estimating central SBP from the peripheral pulse: influence of waveform analysis and calibration error

2011 ◽  
Vol 29 (7) ◽  
pp. 1357-1366 ◽  
Author(s):  
Antoine Guilcher ◽  
Sally Brett ◽  
Shahzad Munir ◽  
Brian Clapp ◽  
Philip J Chowienczyk
2020 ◽  
Vol 86 (5) ◽  
pp. 16-21
Author(s):  
T. A. Karimova ◽  
G. L. Buchbinder ◽  
S. V. Kachin

Calibration by the concentration ratio provides better metrological characteristics compared to other calibration modes when using the inductively coupled plasma atomic emission spectrometry (ICP-AES) for analysis of geological samples and technical materials on their base. The main reasons for the observed improvement are: i) elimination of the calibration error of measuring vessels and the error of weighing samples of the analyzed materials from the total error of the analysis; ii) high intensity of the lines of base element; and iii) higher accuracy of measuring the ratio of intensities compared to that of measuring the absolute intensities. Calcium oxide is better suited as a base when using calibration by the concentration ratio in analysis of carbonate rocks, technical materials, slags containing less than 20% SiO2 and more than 20% CaO. An equation is derived to calculate the content of components determined in carbonate materials when using calibration by the concentration ratio. A method of ICP-AES with calibration by the concentration ratio is developed for determination of CaO (in the range of contents 20 – 100%), SiO2 (2.0 – 35%), Al2O3 (0.1 – 30%), MgO (0.1 – 20%), Fe2O3 (0.5 – 40%), Na2O (0.1 – 15%), K2O (0.1 – 5%), P2O5 (0.001 – 2%), MnO (0.01 – 2%), TiO2 (0.01 – 2.0%) in various carbonate materials. Acid decomposition of the samples in closed vessels heated in a HotBlock 200 system is proposed. Correctness of the procedure is confirmed in analysis of standard samples of rocks. The developed procedure was used during the interlaboratory analysis of the standard sample of slag SH17 produced by ZAO ISO (Yekaterinburg, Russia).


2021 ◽  
Author(s):  
R. I. Rojas-Jiménez ◽  
A. Muñoz-Diosdado ◽  
J. A. Zamora-Justo

Author(s):  
Christoph Kolja Boese ◽  
Tim Rolvien ◽  
Matthias Trost ◽  
Michael Frink ◽  
Jan Hubert ◽  
...  

Abstract Objective Preoperative digital templating is a standard procedure in total hip arthroplasty. Deviations between template size and final implant size may result from inaccurate calibration, templating as well as intraoperative decisions. So far, the explicit effect of calibration errors on templating has not been addressed adequately. Materials and Methods A mathematical simulation of calibration errors up to ± 24% was applied to the templating of acetabular cups (38 to 72 mm diameter). The effect of calibration errors on template component size as deviation from optimal size was calculated. Results The relationship between calibration error and component size deviation is inverse and linear. Calibration errors have a more pronounced effect on larger component sizes. Calibration errors of 2–6% result in templating errors of up to two component sizes. Common errors of up to 12% may result in templating errors of 3–4 sizes for common implant sizes. A tabular matrix visualizes the effect. Conclusion Calibration errors play a significant role in component size selection during digital templating. Orthopedic surgeons should be aware of this effect and try to identify and address this source of error.


2021 ◽  
Vol 104 (2) ◽  
pp. 003685042110131
Author(s):  
João Gaspar-Marques ◽  
Teresa Palmeiro ◽  
Iolanda Caires ◽  
Paula Leiria Pinto ◽  
Nuno Neuparth ◽  
...  

Though the approach used to classify chronic respiratory diseases is changing to a treatable-traits (TT) approach, data regarding very elderly patients is lacking. The objectives of this study were to assess TT frequency in very elderly patients and to study the link between extrapulmonary TT and ventilatory defects. Individuals (≥75 years) residing in elderly care centres answered a standardised questionnaire, underwent spirometry, atopy and fractional exhaled nitric oxide assessments and had their blood pressure and peripheral pulse oximetry measured. Pulmonary, extrapulmonary and behavioural TT were evaluated. Outcome variables were an airflow limitation (post-bronchodilator z-score FEV1/FVC<−1.64) and a restrictive spirometry pattern (z-score FEV1/FVC ≥ +1.64 and z-score FVC<−1.64). Seventy-two percent of the individuals who took part in the study ( n = 234) were women, and the median age of participants was 86 (IQR: 7.4). At least one pulmonary TT was identified in 105 (44.9%) individuals. The most frequent extrapulmonary TTs were: persistent systemic inflammation (47.0%), anaemia (34.4%), depression (32.5%) and obesity (27.4). Airflow limitation was exclusively associated with smoking (OR 5.03; 95% CI 1.56–16.22). A restrictive spirometry pattern was associated with cognitive impairment (OR: 3.89; 95% CI: 1.55–9.79). A high frequency of various TTs was found. The novel association between a restrictive spirometry pattern and cognitive impairment highlights the urgency of clinical research on this vulnerable age group.


Sign in / Sign up

Export Citation Format

Share Document