Episodes of Microbial Keratitis With Therapeutic Silicone Hydrogel Bandage Soft Contact Lenses

2013 ◽  
Vol 39 (6) ◽  
pp. 415
Author(s):  
&NA;
2013 ◽  
Vol 39 (5) ◽  
pp. 324-328 ◽  
Author(s):  
Arvind Saini ◽  
Christopher J. Rapuano ◽  
Peter R. Laibson ◽  
Elisabeth J. Cohen ◽  
Kristin M. Hammersmith

2016 ◽  
Vol 16 (3) ◽  
pp. 117-120 ◽  
Author(s):  
T.N. Safonova ◽  
◽  
I.A. Novikov ◽  
V.I. Boev ◽  
O.V. Gladkova ◽  
...  

2006 ◽  
Vol 65 (2) ◽  
Author(s):  
W.D.H. Gillan

Introduction: The investigation of myopia and soft contact lenses is not new. Many reports show  that  the  wearing  of  silicone  hydrogel lenses as opposed to conventional disposable hydrogel lenses results in little progression of myopia in the eyes wearing silicone hydrogels. Method: Six subjects wore a silicone hydro-gel lens on one eye while the other eye wore a habitual disposable hydrogel lens for six months of daily wear. Fifty measurements of refractive state in each eye were taken prior to the subjects wearing a silicone lens in one eye and a conven-tional hydrogel lens in the other eye. After six months of daily wear another fifty measurements of refractive state were taken for each subject. Results:  Although  there  is  no  statisti-cal  support  for  the  findings  of  this  study, comet stereo-pairs are used to show the chang-es in refractive state for each subject. Four of  the  six  subjects  showed  an  increase  in myopia in the eye wearing the silicone lens. Discussion:  The  increase  in  myopia in eyes wearing a silicone hydrogel lens is contrary  to  the  findings  of  other  studies.


Author(s):  
Ekaterina B. GORSHENYOVA ◽  
Nataliya M. SUTORMINA

There are more than 80 million users of soft contact lenses in the world - 10-15 % of the population. The prevalence of meibomyus gland dysfunction is 43-61 % with the prevalence of obstructive form and the development of lipodeficiency in lacrimal film. At the same time, the use of traditional tear substitutes based on hyaluronic acid is ineffective and the problem of finding a tear substitute with exposure to all 3 layers of lacrimal film becomes relevant. Nanoemulsion “Cationorm” is created as a means of pathogenetic therapy of dry eye syndrome against the background of lipodeficiency, however, there weren't any studies of its effectiveness in obstructive form of meibomyus gland dysfunction among users of soft contact lenses. We examined 3 layers of lacrimal film with the help of Norn's sample with determination of time of lacrimal film break, bio-measurement of lacrimal meniscus and biomicoscopy of eyelid edge region at painting of lissamino-om green. The study involved 28 young carriers of silicone-hydrogel contact lenses with signs of obstructive form of meibomyus gland dysfunction, who we divided into two groups: a control group used to eliminate the symptoms of a hyaluronic acid-based tear substitute, and an experimental group using the drug “Cationorm”. We revealed prolonged effect of nanoemulsion “Cationorm” on all three layers of lacrimal film, which hasn't only symptom lacrimal, but has pathogenetic therapeutic delayed effect among users of soft contact lenses with obstructive form of dysfunction of meibomyum glands, and nanostimer of lipid microspheres provides full compatibility even with material of silicone-hydrogel soft contact lenses. We proved the protective effect of the preparation on ocular epithelium cells.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Se Eun Lee ◽  
So Ra Kim ◽  
Mijung Park

Purpose. To investigate the effect of tear protein deposition on the change in oxygen permeability (Dk) of soft contact lenses (SCL). Methods. Three hydrogel lenses (polymacon, nelfilcon A, and etafilcon A) and two silicon hydrogel lenses (lotrafilcon A and balafilcon A) were investigated. Etafilcon A lenses were incubated in artificial tear solution for 1, 6, 12, and 48 h, whereas the other SCL were incubated for 1, 3, 7, and 14 days. Oxygen permeability was measured using the polarographic method, and lenses were stacked in four layers to correct the boundary effect. Results. The Dk of all investigated SCL was decreased by the protein deposition. Silicone hydrogel lenses showed a smaller deposition of artificial tear proteins than conventional hydrogel lenses. However, their Dk was reduced twofold than those of 3 conventional hydrogel lenses when compared at the same level of protein deposition. Despite a large amount of total deposited protein in etafilcon A lenses, their Dk was more stable than other SCL. Conclusions. From the results, it was revealed that the Dk of SCL is different from the value provided by manufacturers because of the tear protein deposition on surface and/or in pore of SCL; however, the degree of Dk change in SCL was not simply correlated with the amount of tear protein deposition. Thus, it is considered that the correlation between tear protein deposition and properties of lens materials affects Dk change.


2021 ◽  
Vol 23 (1) ◽  
pp. 25-35
Author(s):  
Eghosasere Iyamu ◽  
Frederick Osaro Ekhaise

Purpose: The aim of this study was to investigate the adhesion of bacteria to worn silicone hydrogel and conventional soft contact lenses.Methods: Bacterial adhesion experiments / assays were performed on 24 worn and 6 unworn soft contact lenses each of different materials (high- and low- gas permeable lenses) using the strains such as Pseudomonas aeruginosa ATCC 27853 and Staphylococcus aureus ATCC 25923.Results: P. aeruginosa adhered in increased number to worn than unworn Lotrafilcon A and conventional lenses. However, a higher number of P. aeruginosa adhered to unworn than worn Lotrafilcon B, the difference in the mean adhesion was not significant (p = 0.66). S. aureus adhered in significantly decreased number to worn Lotrafilcon A, nelfilcon A, nesofilcon A, etafilcon A and omafilcon A (p<0.05); butsignificantly higher number adhered to worn than unworn polymacon (p<0.05). Lens wear had no effect on the adhesion of S. aureus to Lotrafilcon B (p>0.05). The least adhesion of P. aeruginosa to worn contact lenses was seen with polymacon, while S. aureus adhered in least number to worn Lotrafilcon A compared to the other contact lens materials that demonstrated the same trend in adhesion.Conclusion: The higher adhesion of P. aeruginosa to worn lenses is consistent with the claim that it is the most implicated in all culture-positive contact lens related bacterial keratitis. Lens wear has different effects on bacterial adhesion, which may be due to type of lens materials and bacterial species/genera studied. Keywords: Silicone hydrogel lenses, conventional lenses, Pseudomonas aeruginosa, Staphylococcus aureus, bacterial adhesion.


Sign in / Sign up

Export Citation Format

Share Document