scholarly journals International Expert Consensus on Sutureless and Rapid Deployment Valves in Aortic Valve Replacement Using Minimally Invasive Approaches

Author(s):  
Mattia Glauber ◽  
Simon C. Moten ◽  
Eugenio Quaini ◽  
Marco Solinas ◽  
Thierry A. Folliguet ◽  
...  

Objective To define the benefit of sutureless and rapid deployment valves in current minimally invasive approaches in isolated aortic valve replacement. Methods A panel of 28 international experts with expertise in both minimally invasive aortic valve replacement and rapid deployment valves was constituted. After thorough literature review, the experts rated evidence-based recommendations in a modified Delphi approach. Results No guideline could be retrieved. Thirty-three clinical trials and 9 systematic reviews could be identified for detailed text analysis to obtain a total of 24 recommendations. After rating by the experts 12, final recommendations were identified: preoperative computed to-mographic scan as well as intraoperative transesophageal echocardiography are highly recommended. Suitable annular sizes are 19 to 27 mm. There is a contraindication for bicuspid valves only for type 0 and for annular abscess or destruction due to infective endocarditis. The use of sutureless and rapid deployment valves reduces extracorporeal circulation and aortic cross-clamp time and leads to less early complications as prolonged ventilation, blood transfusion, atrial fibrillation, pleural effusions, paravalvular leakages and aortic regurgitation, and renal replacement therapy, respectively. These clinical outcomes result in reduced intensive care unit and hospital stay and reduced costs. The use of sutureless and rapid deployment valves will lead to a higher adoption rate of minimally invasive approaches in aortic valve replacement. Respect should be taken to a necessary short learning curve for both sutureless and minimally invasive programs. Conclusions Sutureless and rapid deployment aortic valve replacement together with minimally invasive approaches offers an attractive option in aortic valve placement for patients requiring biological valve replacement.

Author(s):  
Augusto D’Onofrio ◽  
Chiara Tessari ◽  
Giulia Lorenzoni ◽  
Giorgia Cibin ◽  
Gian Luca Martinelli ◽  
...  

Author(s):  
Thorsten C. W. Wahlers ◽  
Martin Andreas ◽  
Parwis Rahmanian ◽  
Pascal Candolfi ◽  
Barbora Zemanova ◽  
...  

Objective The aim of this study was to compare outcomes after rapid-deployment aortic valve replacement (RDAVR) and conventional aortic valve replacement (AVR) from two studies. Methods Patients who underwent RDAVR (INTUITY valve) in the prospective, 5-year, single-arm multicenter TRITON study, or conventional AVR (Perimount Magna Ease valve) in the prospective Perimount Magna Ease postmarket study, were propensity score matched and compared for procedural, hemodynamic, safety, and clinical outcomes. Results Matched RDAVR (n = 106) and conventional AVR (n = 106) patients had similar baseline characteristics (mean ± SD age, 72.8 ± 7.6 vs 72.5 ± 7.4 years; male 59.4% vs 61.3%) and procedures (concomitant procedures: 41.5% vs 50.9%). Mean ± SD aortic cross-clamp time was significantly shorter in RDAVR than AVR patients (51.8 ± 20.9 vs 73.9 ± 33.2 minutes; P < 0.001), as was mean cardiopulmonary bypass time (82.8 ± 34.2 vs 102.4 ± 41.7 minutes; P < 0.001). At 1 year, RDAVR patients showed significantly lower mean ± SD and peak aortic valve gradients (9.0 ± 3.4 and 17.0 ± 6.2 mm Hg, respectively) than conventional AVR patients (13.4 ± 5.5 and 24.2 ± 10.8 mm Hg, respectively; all P < 0.001). Patient-prosthesis mismatch was significantly less common with RDAVR than with AVR [overall: 16/66 (24.2%) vs 46/76 (60.5%); P = 0.007; severe: 2/66 (3.0%) vs 13/76 (17.1%)]. There were no significant differences between the RDAVR and AVR groups regarding 30-day safety endpoints. Survival rates in the RDAVR and conventional AVR groups were, respectively, 99.1% and 100.0% at 30 days, 97.1% and 95.1% at 1 year, and 93.3% and 94.1% at 3 years ( P = nonsignificant). Conclusions In this retrospective study with matched populations, the RDAVR with the INTUITY valve system provided superior procedural and hemodynamic outcomes than a standard bioprosthesis without compromising safety.


2019 ◽  
Vol 56 (4) ◽  
pp. 793-799 ◽  
Author(s):  
Paolo Berretta ◽  
Martin Andreas ◽  
Thierry P Carrel ◽  
Marco Solinas ◽  
Kevin Teoh ◽  
...  

Abstract OBJECTIVES: The impact of sutureless and rapid deployment (SURD) valves on the clinical outcomes of patients undergoing minimally invasive aortic valve replacement (MI-AVR) has still to be defined. The aim of this study was to assess clinical characteristics and in-hospital results of patients receiving SURD-AVR through less invasive approaches in the large population of the Sutureless and Rapid Deployment International Registry (SURD-IR). METHODS: Of the 1935 patients who received primary isolated SURD-AVR between 2009 and 2018, a total of 1418 (73.3%) underwent MI interventions and were included in this analysis. SURD-AVR was performed using upper ministernotomy in 56.4% (n = 800) of cases and anterior right thoracotomy in 43.6% (n = 618). Perceval S was implanted in 1011 (71.3%) patients and Edwards Intuity or Intuity Elite in 407 (28.7%) patients. RESULTS: Overall in-hospital mortality and stroke rates were 1.7% and 2%, respectively. A definitive pacemaker implantation was reported in 9% of cases and significantly decreased over the observational period, from 20.6% to 5.6% (P = 0.002). The Perceval valve was associated with shorter operative times and was more frequently implanted in patients receiving anterior right thoracotomy incision. The Intuity valve was preferred in younger patients and revealed superior postoperative haemodynamic results. CONCLUSIONS: SURD-AVR was largely performed through less invasive approaches and can be considered as a primary indication in MI surgery. In the SURD-IR cohort, MI SURD-AVR using both Perceval and Intuity valves appeared a safe and reproducible procedure associated with promising early results.


Author(s):  
Aristidis Lenos ◽  
Anno Diegeler

During the past decade, many surgeons have focused their interest on the development and improvement of minimally invasive techniques for aortic valve replacement. Although the minimally invasive approaches for the treatment of mitral valve disease have been standardized, the preferred route for aortic valve replacement remains a matter of debate. Access through a right minithoracotomy avoids opening the sternum; however, it requires a greater surgical ability and a learning period, even for experienced surgeons. This enhances the role of sutureless prostheses because these devices are associated with easier placement, excellent hemodynamic performance, and acceptable rates of pacemaker implantation and paravalvular leak. Herein, we report a series of 10 consecutive patients who received an EDWARDS INTUITY rapid deployment valve (Edwards Lifesciences, Irvine, CA USA) by a right minithoracotomy.


2015 ◽  
Vol 99 (1) ◽  
pp. 17-25 ◽  
Author(s):  
Michael A. Borger ◽  
Vadim Moustafine ◽  
Lenard Conradi ◽  
Christoph Knosalla ◽  
Markus Richter ◽  
...  

2020 ◽  
Vol 58 (5) ◽  
pp. 1063-1071 ◽  
Author(s):  
Martin Andreas ◽  
Paolo Berretta ◽  
Marco Solinas ◽  
Giuseppe Santarpino ◽  
Utz Kappert ◽  
...  

Abstract OBJECTIVES Minimally invasive surgical techniques with optimal outcomes are of paramount importance. Sutureless and rapid deployment aortic valves are increasingly implanted via minimally invasive approaches. We aimed to analyse the procedural outcomes of a full sternotomy (FS) compared with those of minimally invasive cardiac surgery (MICS) and further assess MICS, namely ministernotomy (MS) and anterior right thoracotomy (ART). METHODS We selected all isolated aortic valve replacements in the Sutureless and Rapid Deployment Aortic Valve Replacement International Registry (SURD-IR, n = 2257) and performed propensity score matching to compare aortic valve replacement through FS or MICS (n = 508/group) as well as through MS and ART accesses (n = 569/group). RESULTS Postoperative mortality was 1.6% in FS and MICS patients who had a mean logistic EuroSCORE of 11%. Cross-clamp and cardiopulmonary bypass (CPB) times were shorter in the FS group than in the MICS group (mean difference 3.2 and 9.2 min; P &lt; 0.001). Patients undergoing FS had a higher rate of acute kidney injury (5.6% vs 2.8%; P = 0.012). Direct comparison of MS and ART revealed longer mean cross-clamp and CPB times (12 and 16.7 min) in the ART group (P &lt; 0.001). The postoperative outcome revealed a higher stroke rate (3.2% vs 1.2%; P = 0.043) as well as a longer postoperative intensive care unit [2 (1–3) vs 1 (1–3) days; P = 0.009] and hospital stay [11 (8–16) vs 8 (7–12) days; P &lt; 0.001] in the MS group than in the ART group. CONCLUSIONS According to this non-randomized international registry, FS resulted in a higher rate of acute kidney injury. The ART access showed a lower stroke rate than MS and a shorter hospital stay than all other accesses. All these findings may be related to underlying patient risk factors.


Author(s):  
Jure Jug ◽  
Zdravko Štor ◽  
Borut Geršak

Abstract OBJECTIVES Prolonged operative times, potentially leading to increased morbidity, are a possible drawback of minimally invasive aortic valve replacement. The aim of this study was to assess the impact of anatomical circumstances in the chest on aortic cross-clamp time. METHODS This retrospective study included 68 patients who underwent minimally invasive aortic valve replacement with the Perceval sutureless valve via right-anterior thoracotomy or with ministernotomy. Anatomical variables were measured during preoperative computer tomography scans. RESULTS Aortic cross-clamp time was shorter in those having ministernotomy than in the right-anterior thoracotomy group (41.1 vs 52.3 min; P &lt; 0.001). Cardiopulmonary bypass (CPB) time was not significantly different between groups (P = 0.09). A multivariable linear-regression model (P = 0.018) showed the aortic dextroposition variable to be a significant predictor of the aortic cross-clamp method and CPB times (P = 0.005 and P = 0.003) independent of other anatomical variables in the right thoracotomy group (10 mm deviation from optimal position prolonged the times for 240 and 600 s). For the whole cohort, a correlation between aortic valve dimensions and operative times was found (P = 0.046, P = 0.009). A linear-regression model (P = 0,046) predicted 90 s longer aortic cross-clamp time and 231 s longer CPB time for every 1 mm smaller aortic valve diameter. CONCLUSIONS The anatomical variables are associated with the operative times in minimally invasive aortic valve replacement with sutureless valves. Considering this association, preplanning the procedure is recommended.


Sign in / Sign up

Export Citation Format

Share Document