Epicardial, Biatrial Ablation with Integrated Uni-Bipolar Radiofrequency Technology in Stand-Alone Persistent Atrial Fibrillation

Author(s):  
Fabrizio Rosati ◽  
Claudio Muneretto ◽  
Elisa Merati ◽  
Gianluca Polvani ◽  
Massimo Moltrasio ◽  
...  

Objective Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. Methods Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm. Results Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation. Conclusions Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve outcomes in patients with nonparoxysmal atrial fibrillation.

Author(s):  
John R. Doty ◽  
Stephen E. Clayson

Objective Surgical ablation with radiofrequency is a safe and effective treatment for atrial fibrillation. Recent advances in instrumentation have allowed for the application of bipolar radiofrequency through a minimally invasive approach using small bilateral thoracotomies for pulmonary vein isolation, destruction of autonomic ganglia, and excision of the left atrial appendage (GALAXY procedure). Methods Thirty-two patients underwent surgical ablation of atrial fibrillation with the GALAXY procedure over a 43-month period. Data were collected in a prospective manner during hospitalization and at 1-, 3-, 6-, and 12-month intervals for rhythm, medications, and subsequent interventions. Results There were no operative mortality, no myocardial infarction, and no stroke. One patient required reexploration for bleeding. Mean follow-up was 28 months (range, 4–43 months). Freedom from atrial fibrillation at 12 and 24 months, respectively, was 90% and 67% for patients with paroxysmal fibrillation and 80% and 63% for patients with persistent atrial fibrillation. Of the patients who were not in sinus rhythm, four reverted to atrial fibrillation and two reverted to atrial flutter. Conclusions The GALAXY procedure is a safe and effective, minimally invasive method for treatment of isolated (lone) atrial fibrillation. The operation provides excellent short-term freedom from atrial fibrillation and should be considered in patients with isolated paroxysmal atrial fibrillation.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Wei Si ◽  
Sijia Yang ◽  
Linhui Pan ◽  
Chengchegn Li ◽  
Liang Ma

Abstract Background and aim of the study Atrial fibrillation (AF) is the most common atrial arrhythmia. Our aim was to compare the outcomes of atrial fibrillation treatment with original modified minimally invasive MAZE using monopolar radiofrequency ablation (mi-MAZE) and open surgery MAZE using bipolar radiofrequency ablation (os-MAZE). Methods We searched the associated patients’ information on the medical record system of the First Affiliated Hospital, School of Medicine, Zhejiang University. Statistical Package for Social Sciences (SPSS) was used to analyse the data. The primary outcome is the atrial fibrillation ablation rate 3 months, 6 months, 12 months after operation. And secondary outcome is the postoperative quality of life. Results The mi-MAZE group included 42 patients and the os-MAZE group had 65 patients. Three months after surgery, we found that 31 patients (77.5%) in the mi-MAZE group were sinus rhythm and 44 (71.0%) recovered sinus rhythm in the os-MAZE group. We followed up these patients on the phone or in person and scored them on the SF-36 scale. The results were found to be 120.2 ± 8.10 vs 110.6 ± 6.58 (mi-MAZE vs os-MAZE, P < 0.001). Conclusions There was no significant difference of atrial fibrillation ablation rate (sinus rhythm recovery rate) between the mi-MAZE group and the os-MAZE group. The postoperative quality of life in mi-MAZE group was higher than that in os-MAZE group.


2017 ◽  
Vol 28 (11) ◽  
pp. 1259-1268
Author(s):  
Shiro Nakahara ◽  
Yuichi Hori ◽  
Naoki Nishiyama ◽  
Yasuo Okumura ◽  
Reiko Fukuda ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document