The Impact of Cochlear Implants From the Perspective of Significant Others of Adult Cochlear Implant Users

2008 ◽  
Vol 29 (5) ◽  
pp. 607-614 ◽  
Author(s):  
Veronica Kennedy ◽  
Dafydd Stephens ◽  
Pamela Fitzmaurice
2014 ◽  
Vol 57 (3) ◽  
pp. 1108-1126 ◽  
Author(s):  
Ruth M. Reeder ◽  
Jill B. Firszt ◽  
Laura K. Holden ◽  
Michael J. Strube

PurposeThe purpose of this study was to examine the rate of progress in the 2nd implanted ear as it relates to the 1st implanted ear and to bilateral performance in adult sequential cochlear implant recipients. In addition, this study aimed to identify factors that contribute to patient outcomes.MethodThe authors performed a prospective longitudinal study in 21 adults who received bilateral sequential cochlear implants. Testing occurred at 6 intervals: prebilateral through 12 months postbilateral implantation. Measures evaluated speech recognition in quiet and noise, localization, and perceived benefit.ResultsSecond ear performance was similar to 1st ear performance by 6 months postbilateral implantation. Bilateral performance was generally superior to either ear alone; however, participants with shorter 2nd ear length of deafness (<20 years) had more rapid early improvement and better overall outcomes than those with longer 2nd ear length of deafness (>30 years). All participants reported bilateral benefit.ConclusionsAdult cochlear implant recipients demonstrated benefit from 2nd ear implantation for speech recognition, localization, and perceived communication function. Because performance outcomes were related to length of deafness, shorter time between surgeries may be warranted to reduce negative length-of-deafness effects. Future study may clarify the impact of other variables, such as preimplant hearing aid use, particularly for individuals with longer periods of deafness.


Author(s):  
Anuradha R. Bantwal ◽  
Rashmi Deshpande ◽  
Rewa Indurkar ◽  
Salaj Bhatnagar ◽  
Meenakshi Wadhera ◽  
...  

2021 ◽  
pp. 1-10
Author(s):  
Christiane Völter ◽  
Lisa Götze ◽  
Imme Haubitz ◽  
Janine Müther ◽  
Stefan Dazert ◽  
...  

<b><i>Introduction:</i></b> Age-related hearing loss affects about one-third of the population worldwide. Studies suggest that hearing loss may be linked to cognitive decline and auditory rehabilitation may improve cognitive functions. So far, the data are limited, and the underlying mechanisms are not fully understood. The study aimed to analyze the impact of cochlear implantation on cognition in a large homogeneous population of hearing-impaired adults using a comprehensive non-auditory cognitive assessment with regard to normal-hearing (NH) subjects. <b><i>Material and Methods:</i></b> Seventy-one cochlear implant (CI) candidates with a postlingual, bilateral severe or profound hearing loss aged 66.3 years (standard deviation [SD] 9.2) and 105 NH subjects aged 65.96 years (SD 9.4) were enrolled. The computer-based neurocognitive tool applied included 11 subtests covering attention (M3), short- and long-term memory (recall and delayed recall), working memory (0- and 2-back, Operation Span [OSPAN] task), processing speed (Trail Making Test [TMT] A), mental flexibility (TMT B), inhibition (cFlanker and iFlanker), and verbal fluency. CI patients underwent a neurocognitive testing preoperatively as well as 12 months postoperatively. Impact of hearing status, age, gender, and education on cognitive subdomains was studied. Additionally, after controlling for education and age, cognitive performance of CI subjects (<i>n</i> = 41) was compared to that of NH (<i>n</i> = 34). <b><i>Results:</i></b> CI users achieved significantly better neurocognitive scores 12 months after cochlear implantation than before in most subtests (M3, [delayed] recall, 2-back, OSPAN, iFlanker, and verbal fluency; all <i>p</i> &#x3c; 0.05) except for the TMT A and B. A significant correlation could be found between the postoperative improvement in speech perception and in the attentional task M3 (<i>p</i> = 0.01). Hearing status (<i>p</i> = 0.0006) had the strongest effect on attention, whereas education had a high impact on recall (<i>p</i> = 0.002), OSPAN (<i>p</i> = 0.0004), and TMT A (<i>p</i> = 0.005) and B (<i>p</i> = 0.003). Inhibition was mainly age-dependent with better results in younger subjects (<i>p</i> = 0.016). Verbal fluency was predicted by gender as females outperformed men (<i>p</i> = 0.009). Even after controlling for age and education NH subjects showed a significantly better performance than CI candidates in the recall (<i>p</i> = 0.03) and delayed recall (<i>p</i> = 0.01) tasks. Postoperatively, there was no significant difference between the 2 groups anymore. <b><i>Conclusion:</i></b> Impact of cochlear implantation on neurocognitive functions differs according to the cognitive subdomains. Postoperatively, CI recipients performed as good as age- and education-matched NH subjects.


Author(s):  
C Thomas ◽  
J Westwood ◽  
G F Butt

Abstract Background YouTube is increasingly used as a source of healthcare information. This study evaluated the quality of videos on YouTube about cochlear implants. Methods YouTube was searched using the phrase ‘cochlear implant’. The first 60 results were screened by two independent reviewers. A modified Discern tool was used to evaluate the quality of each video. Results Forty-seven videos were analysed. The mean overall Discern score was 2.0 out of 5.0. Videos scored higher for describing positive elements such as the benefits of a cochlear implant (mean score of 3.4) and scored lower for negative elements such as the risks of cochlear implant surgery (mean score of 1.3). Conclusion The quality of information regarding cochlear implant surgery on YouTube is highly variable. These results demonstrated a bias towards the positive attributes of cochlear implants, with little mention of the risks or uncertainty involved. Although videos may be useful as supplementary information, critical elements required to make an informed decision are lacking. This is of particular importance when patients are considering surgery.


2017 ◽  
Vol 38 (8) ◽  
pp. e285-e288 ◽  
Author(s):  
Brent Jerome Wilkerson ◽  
Sandra F. Porps ◽  
Seilesh C. Babu

Author(s):  
A. Molisz ◽  
A. Zarowski ◽  
E. Cardinael ◽  
A. Vermeiren ◽  
T. Theunen ◽  
...  

Abstract Background Fitting cochlear implants in babies and noncooperative patients is cumbersome and time consuming. Therefore, objective parameters have been sought in order to predict the subjective threshold (T) and maximum comfort (C) levels. Measurements of the electrically evoked compound action potentials (ECAPs) have been widely used for this purpose, yet the correlation between these objective measures and the subjective T/C levels is weak to moderate. Purpose This article aims (1) to evaluate correlations between the subjective parameters of the fitting maps such as thresholds (T level) and maximum comfort levels (C level), the impedance of the electrode contacts, and the ECAP thresholds, and (2) to compare the value of the electrode impedances and the ECAP measures for prediction of the T/C levels. Research Design Case review study in a quaternary otologic referral center. Study Sample Ninety-eight consecutive CI patients were enrolled. The average age of the patients was 49 years. All patients were users of the Nucleus 24RECA (Freedom, Contour Advance-of-Stylet electrode) cochlear implant. Data Collection and Analysis Data on impedance of the electrode contacts and the behavioral T/C levels at the first fitting session (2–5 weeks after surgery) and at the 5th fitting session (4–6 months after surgery) have been retrospectively collected in 98 consecutive CI patients. Additionally, the intraoperative impedance values and the ECAP thresholds (tNRT) have been recorded. Results Impedances of electrode contacts show significant strong negative correlations with the stabilized T/C levels at 4 to 6 months after implantation and are an important predictor for the behavioral T/C levels. They can explain R 2 = 28 to 41% of the variability of the behavioral T/C levels. In multiple regression analysis electrode contact impedances can explain twice as much of the variability of the stabilized T/C levels than the tNRT values. The electrode impedances together with the tNRT values are able to explain R 2 = 37 to 40% of the global variability of the T/C levels while the tNRT thresholds solely are able to explain only R 2 = 5 to 14% of the T/C levels variability. Conclusion Impedances of electrode contacts correlate strongly with the stabilized behavioral T/C levels and may be used as an objective measure for fitting of cochlear implants.


2016 ◽  
Vol 21 (03) ◽  
pp. 206-212 ◽  
Author(s):  
Grace Ciscare ◽  
Erika Mantello ◽  
Carla Fortunato-Queiroz ◽  
Miguel Hyppolito ◽  
Ana Reis

Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1.


1996 ◽  
Vol 39 (3) ◽  
pp. 604-610 ◽  
Author(s):  
Nancy Tye-Murray ◽  
Linda Spencer ◽  
Elizabeth Gilbert Bedia ◽  
George Woodworth

Twenty children who have worn a Cochlear Corporation cochlear implant for an average of 33.6 months participated in a device-on/off experiment. They spoke 14 monosyllabic words three times each after having not worn their cochlear implant speech processors for several hours. They then spoke the same speech sample again with their cochlear implants turned on. The utterances were phonetically transcribed by speech-language pathologists. On average, no difference between speaking conditions on indices of vowel height, vowel place, initial consonant place, initial consonant voicing, or final consonant voicing was found. Comparisons based on a narrow transcription of the speech samples revealed no difference between the two speaking conditions. Children who were more intelligible were no more likely to show a degradation in their speech production in the device-off condition than children who were less intelligible. In the device-on condition, children sometimes nasalized their vowels and inappropriately aspirated their consonants. Their tendency to nasalize vowels and aspirate initial consonants might reflect an attempt to increase proprioceptive feedback, which would provide them with a greater awareness of their speaking behavior.


2018 ◽  
Author(s):  
Eline Verschueren ◽  
Ben Somers ◽  
Tom Francart

ABSTRACTThe speech envelope is essential for speech understanding and can be reconstructed from the electroencephalogram (EEG) recorded while listening to running speech. This so-called neural envelope tracking has been shown to relate to speech understanding in normal hearing listeners, but has barely been investigated in persons wearing cochlear implants (CI). We investigated the relation between speech understanding and neural envelope tracking in CI users.EEG was recorded in 8 CI users while they listened to a story. Speech understanding was varied by changing the intensity of the presented speech. The speech envelope was reconstructed from the EEG using a linear decoder and then correlated with the envelope of the speech stimulus as a measure of neural envelope tracking which was compared to actual speech understanding.This study showed that neural envelope tracking increased with increasing speech understanding in every participant. Furthermore behaviorally measured speech understanding was correlated with participant specific neural envelope tracking results indicating the potential of neural envelope tracking as an objective measure of speech understanding in CI users. This could enable objective and automatic fitting of CIs and pave the way towards closed-loop CIs that adjust continuously and automatically to individual CI users.


Sign in / Sign up

Export Citation Format

Share Document