scholarly journals Auditory Speech Perception Development in Relation to Patient's Age with Cochlear Implant

2016 ◽  
Vol 21 (03) ◽  
pp. 206-212 ◽  
Author(s):  
Grace Ciscare ◽  
Erika Mantello ◽  
Carla Fortunato-Queiroz ◽  
Miguel Hyppolito ◽  
Ana Reis

Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1.

2011 ◽  
Vol 22 (09) ◽  
pp. 567-577 ◽  
Author(s):  
Christina L. Runge ◽  
Jamie Jensen ◽  
David R. Friedland ◽  
Ruth Y. Litovsky ◽  
Sergey Tarima

Background: The challenges associated with auditory neuropathy spectrum disorder (ANSD) are due primarily to temporal impairment and therefore tend to affect perception of low- to midfrequency sounds. A common treatment option for severe impairment in ANSD is cochlear implantation, and because the degree of impairment is unrelated to degree of hearing loss by audiometric thresholds, this population may have significant acoustic sensitivity in the contralateral ear. Clinically, the question arises as to how we should treat the contralateral ear in this population when there is acoustic hearing—should we plug it, amplify it, implant it, or leave it alone? Purpose: The purpose of this study was to examine the effects of acute amplification and plugging of the contralateral ear compared to no intervention in implanted children with ANSD and aidable contralateral hearing. It was hypothesized that due to impaired temporal processing in ANSD, contralateral acoustic input would interfere with speech perception achieved with the cochlear implant (CI) alone; therefore, speech perception performance will decline with amplification and improve with occlusion. Research Design: Prospective within-subject comparison. Adaptive speech recognition thresholds (SRTs) for monosyllable and spondee word stimuli were measured in quiet and in noise for the intervention configurations. Study Sample: Nine children treated at the Medical College of Wisconsin Koss Cochlear Implant Program participated in the study. Inclusion criteria for this study were children diagnosed with ANSD who were unilaterally implanted, had aidable hearing in the contralateral ear (defined as a three-frequency pure-tone average of ≤80 dB HL), had at least 1 yr of cochlear implant experience, and were able to perform the speech perception task. Intervention: We compared SRT with the CI alone to SRTs with interventions of cochlear implant with a contralateral hearing aid (CI+HA) and cochlear implant with a contralateral earplug (CI+plug). Data Collection and Analysis: SRTs were measured and compared within subjects across listening conditions. Within-subject comparisons were analyzed using paired t-tests, and analyses of predictive variables for effects of contralateral intervention were analyzed using linear regression. Results: Contrary to the hypothesis, the bimodal CI+HA configuration showed a significant improvement in mean performance over the CI-alone configuration in quiet (p = .04). In noise, SRTs were obtained for six subjects, and no significant bimodal benefit was observed (p = .09). There were no consistent effects of occlusion observed across subjects and stimulus conditions. Degree of bimodal benefit showed a significant relationship with performance with the CI alone, with greater bimodal benefit associated with poorer CI-alone performance (p = .01). This finding, however, was limited by floor effects. Conclusions: The results of this study indicate that children with ANSD who are experienced cochlear implant users may benefit from contralateral amplification, particularly for moderate cochlear implant performers. It is unclear from these data whether long-term contralateral hearing aid use in real-world situations would ultimately benefit this population; however, a hearing aid trial is recommended with assessment of bimodal benefit over time. These data may help inform clinical guidelines for determining optimal hearing configurations for unilaterally implanted children with ANSD, particularly when considering candidacy for sequential cochlear implantation.


1989 ◽  
Vol 98 (8_suppl) ◽  
pp. 2-7 ◽  
Author(s):  
Richard T. Miyamoto ◽  
Mary Joe Osberger ◽  
Wendy A. Myres ◽  
Amy J. Robbins ◽  
Kathy Kessler ◽  
...  

A speech perception hierarchy has been developed and applied to assess the influence of cochlear implants and tactile aids on the acquisition of auditory, speech, and language skills in deaf children. Encouraging improvements were noted with both types of sensory aids at the detection level. The House 3M and Nucleus cochlear implant designs appear to offer advantages over the Tactaid II in providing ancillary speech perception cues to deaf children. Preliminary observations suggest that the multichannel cochlear implant design may be superior to the single-channel coding scheme.


1995 ◽  
Vol 38 (2) ◽  
pp. 327-337 ◽  
Author(s):  
Nancy Tye-Murray ◽  
Linda Spencer ◽  
George G. Woodworth

The four purposes of this investigation were to assess whether children acquire intelligible speech following prolonged cochlear-implant experience and examine their speech error patterns, to examine how age at implantation influences speech acquisition, to assess how speech production and speech perception skills relate, and to determine whether cochlear implant recipients who formerly used simultaneous communication (speech and manually coded English) begin to use speech without sign to communicate. Twenty-eight prelinguistically deafened children who use a Nucleus cochlear implant were assigned to one of three age groups, according to age at implantation: 2–5 yrs (N = 12), 5–8 yrs (N = 9), and 8–15 yrs (N = 7). All subjects had worn a cochlear implant for at least 24 mos, and an average of 36 mos. All subjects used simultaneous communication at the time of implantation. Subjects performed both imitative and structured spontaneous sampling speech tasks. The results permit the following conclusions: (a) children who have used a cochlear implant for at least 2 yrs acquire some intelligible speech; (b) children who receive a cochlear implant before the age of 5 yrs appear to show greater benefit in their speech production skills than children who are older, at least after a minimum of 2 yrs of use; (c) children who recognize more speech while wearing their cochlear implants are likely to speak more intelligibly; and, (d) signing does not disappear from a child’s communication mode following implantation.


2010 ◽  
Vol 21 (01) ◽  
pp. 044-051 ◽  
Author(s):  
Camille C. Dunn ◽  
Ann Perreau ◽  
Bruce Gantz ◽  
Richard S. Tyler

Background: Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. Purpose: The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech-in-noise test with spatially separate noise sources. Research Design: Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results: Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all 11 subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Conclusion: Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise.


2010 ◽  
Vol 20 (2) ◽  
pp. 70-75 ◽  
Author(s):  
Lisa S. Davidson

Cochlear implant (CI) candidacy guidelines continue to evolve as a result of advances in both cochlear implant and hearing aid technology. Empirical studies comparing the speech perception abilities of children using cochlear implants or hearing aids will be reviewed in the context of current device technology and CI candidacy evaluations.


2015 ◽  
Vol 24 (4) ◽  
pp. 462-468 ◽  
Author(s):  
Jessica J. Messersmith ◽  
Lindsey E. Jorgensen ◽  
Jessica A. Hagg

Purpose The purpose of this study was to determine whether an alternate fitting strategy, specifically adjustment to gains in a hearing aid (HA), would improve performance in patients who experienced poorer performance in the bimodal condition when the HA was fit to traditional targets. Method This study was a retrospective chart review from a local clinic population seen during a 6-month period. Participants included 6 users of bimodal stimulation. Two performed poorer in the cochlear implant (CI) + HA condition than in the CI-only condition. One individual performed higher in the bimodal condition, but the overall performance was low. Three age range–matched users whose performance increased when the HA was used in conjunction with a CI were also included. The HA gain was reduced beyond 2000 Hz. Speech perception scores were obtained pre- and postmodification to the HA fitting. Results All listeners whose HA was programmed using the modified approach demonstrated improved speech perception scores with the modified HA fit in the bimodal condition when compared with the traditional HA fit in the bimodal condition. Conclusion Modifications to gains above 2000 Hz in the HA may improve performance for bimodal listeners who perform more poorly in the bimodal condition when the HA is fit to traditional targets.


2019 ◽  
Vol 23 (03) ◽  
pp. e292-e298
Author(s):  
Natalia Martinez Fernandes ◽  
Daniela Gil ◽  
Marisa Frasson de Azevedo

Introduction The mismatch negativity (MMN) is a negative long-latency auditory potential elicited by any discriminable change in a repetitive aspect of auditory stimulation. This evoked potential can provide cortical information about the sound processing, including in children who use cochlear implants. Objective To identify MMN characteristics regarding latency, amplitude, and wave area in cochlear implanted children and to identify associations among language development, speech perception and family involvement. Methods This is a descriptive, observational, cross-sectional study, which compared two groups: study group—children with cochlear implant, and control group—hearing children. The children were submitted to MMN evaluation with non-verbal tone burst stimulus, differing in frequency in sound field at 70 dBHL, with SmartEP equipment (Intelligent Hearing Systems, Miami, FL, USA). Speech perception and language development questionnaires were also applied, and the family participation in the rehabilitation process was classified. Results The occurrence of MMN was 73.3% for the control group and 53.3% for the study group. Values of latency, amplitude and area of MMN of children using cochlear implants were similar to those of hearing children, and did not differ between groups. The occurrence of MMN was not correlated to the variables of hearing, language and family categories. Conclusion Children with cochlear implants showed similar MMN responses to those of the children in the control group, with mean latency, amplitude and area of 208.9 ms (±12.8), -2.37 μV (±0.38) and 86.5 μVms (±23.4), respectively. There was no correlation between the presence of MMN and children's performance in the auditory and language development tests or family involvement during rehabilitation.


2007 ◽  
Author(s):  
James D. Miller ◽  
Charles S. Watson ◽  
Doris J. Kistler ◽  
Frederic L. Wightman ◽  
Jill E. Preminger

1990 ◽  
Vol 33 (2) ◽  
pp. 229-237 ◽  
Author(s):  
Arlene Earley Carney ◽  
Marjorie Kienle ◽  
Richard T. Miyamoto

Suprasegmental and segmental speech perception tasks were administered to 8 patients with single-channel cochlear implants. Suprasegmental tasks included the recognition of syllable number, syllabic stress, and intonation. Segmental tasks included the recognition of vowels and consonants in three modalities: visual only, implant only, and visual + implant. Results were compared to those obtained from artificially deafened adults using a single-channel vibrotactile device (Carney, 1988; Carney & Beachler, 1986). The patterns of responses for both suprasegmental and segmental tasks were highly similar for both groups of subjects, despite differences between the characteristics of the subject samples. These results suggest that single-channel sensory devices, whether they be cochlear implants or vibrotactile aids, produce similar patterns of speech perception errors, even when differences are observed in overall performance level.