Colloidal Gold Nanoparticles as a Blood-Pool Contrast Agent for X-ray Computed Tomography in Mice

2007 ◽  
Vol 42 (12) ◽  
pp. 797-806 ◽  
Author(s):  
Quan-Yu Cai ◽  
Sun Hee Kim ◽  
Kyu Sil Choi ◽  
Soo Yeon Kim ◽  
Seung Jae Byun ◽  
...  
2007 ◽  
Vol 129 (24) ◽  
pp. 7661-7665 ◽  
Author(s):  
Dongkyu Kim ◽  
Sangjin Park ◽  
Jae Hyuk Lee ◽  
Yong Yeon Jeong ◽  
Sangyong Jon

2019 ◽  
Vol 2 (3) ◽  
pp. 1197-1203 ◽  
Author(s):  
Lee Robison ◽  
Lin Zhang ◽  
Riki J. Drout ◽  
Peng Li ◽  
Chad R. Haney ◽  
...  

2010 ◽  
Vol 21 (24) ◽  
pp. 245104 ◽  
Author(s):  
Chie Kojima ◽  
Yasuhito Umeda ◽  
Mikako Ogawa ◽  
Atsushi Harada ◽  
Yasuhiro Magata ◽  
...  

2017 ◽  
Vol 23 (1) ◽  
pp. 9-14 ◽  
Author(s):  
Asghar Mesbahi ◽  
Fatemeh Famouri ◽  
Mohammad Johari Ahar ◽  
Maryam Olade Ghaffari ◽  
Seyed Mostafa Ghavami

AbstractAim: In the current study, some imaging characteristics of AuNPs were quantitatively analyzed and compared with two conventional contrast media (CM) including Iodine and Gadolinium by using of a cylindrical phantom.Methods: AuNPs were synthesized with the mean diameter of 16 nm and were equalized to the concentration of 0.5, 1, 2 and 4 mg/mL in the same volumes. A cylindrical phantom resembling the head and neck was fabricated and drilled to contain small tubes filled with Iodine, Gadolinium, and AuNPs as contrast media. The phantom was scanned in different exposure techniques and CT numbers of three studied contrast media inside test tubes were measured in terms of Hounsfield Unit (HU). The imaging parameters of the noise and contrast to noise ratios (CNR) were calculated for all studied CMs.Results: AuNPs showed 128% and 166% higher CT number in comparison with Iodine and Gadolinium respectively. Also, Iodine had a greater CT number than Gadolinium for the same exposure techniques and concentration. The maximum CT number for AuNPs and studied contrast materials was obtained at the highest mAs and the lowest tube potential. The maximum CT number were 1033±11 (HU) for AuNP, 565±10 (HU) for Iodine, 458±11 for Gadolinium. Moreover, the maximum CNRs of 433±117, 203±53, 145±37 were found for AuNPs, Iodine and Gadolinium respectively.Conclusion: The contrast agent based on AuNPs showed higher imaging quality in terms of contrast and noise relative to other iodine and gadolinium based contrast media in X-ray computed tomography. Application of the AuNPs as a contrast medium in x-ray CT is recommended.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Stephanie Kulpe ◽  
Martin Dierolf ◽  
Benedikt Günther ◽  
Madleen Busse ◽  
Klaus Achterhold ◽  
...  

Abstract In clinical diagnosis, X-ray computed tomography (CT) is one of the most important imaging techniques. Yet, this method lacks the ability to differentiate similarly absorbing substances like commonly used iodine contrast agent and calcium which is typically seen in calcifications, kidney stones and bones. K-edge subtraction (KES) imaging can help distinguish these materials by subtracting two CT scans recorded at different X-ray energies. So far, this method mostly relies on monochromatic X-rays produced at large synchrotron facilities. Here, we present the first proof-of-principle experiment of a filter-based KES CT method performed at a compact synchrotron X-ray source based on inverse-Compton scattering, the Munich Compact Light Source (MuCLS). It is shown that iodine contrast agent and calcium can be clearly separated to provide CT volumes only showing one of the two materials. These results demonstrate that KES CT at a compact synchrotron source can become an important tool in pre-clinical research.


2007 ◽  
Vol 2 (6) ◽  
pp. 292-293
Author(s):  
S. Roux ◽  
C. Alric ◽  
J. Taleb ◽  
C. Mandon ◽  
C. Billotey ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document