compact light source
Recently Published Documents


TOTAL DOCUMENTS

41
(FIVE YEARS 11)

H-INDEX

8
(FIVE YEARS 2)

2020 ◽  
Vol 47 (10) ◽  
pp. 5183-5193 ◽  
Author(s):  
Karin Burger ◽  
Theresa Urban ◽  
Annique C. Dombrowsky ◽  
Martin Dierolf ◽  
Benedikt Günther ◽  
...  

2020 ◽  
Vol 27 (5) ◽  
pp. 1395-1414 ◽  
Author(s):  
Benedikt Günther ◽  
Regine Gradl ◽  
Christoph Jud ◽  
Elena Eggl ◽  
Juanjuan Huang ◽  
...  

Inverse Compton scattering provides means to generate low-divergence partially coherent quasi-monochromatic, i.e. synchrotron-like, X-ray radiation on a laboratory scale. This enables the transfer of synchrotron techniques into university or industrial environments. Here, the Munich Compact Light Source is presented, which is such a compact synchrotron radiation facility based on an inverse Compton X-ray source (ICS). The recent improvements of the ICS are reported first and then the various experimental techniques which are most suited to the ICS installed at the Technical University of Munich are reviewed. For the latter, a multipurpose X-ray application beamline with two end-stations was designed. The beamline's design and geometry are presented in detail including the different set-ups as well as the available detector options. Application examples of the classes of experiments that can be performed are summarized afterwards. Among them are dynamic in vivo respiratory imaging, propagation-based phase-contrast imaging, grating-based phase-contrast imaging, X-ray microtomography, K-edge subtraction imaging and X-ray spectroscopy. Finally, plans to upgrade the beamline in order to enhance its capabilities are discussed.


2020 ◽  
Vol 27 (1) ◽  
pp. 164-175 ◽  
Author(s):  
Kaye Susannah Morgan ◽  
David Parsons ◽  
Patricia Cmielewski ◽  
Alexandra McCarron ◽  
Regine Gradl ◽  
...  

Small-animal physiology studies are typically complicated, but the level of complexity is greatly increased when performing live-animal X-ray imaging studies at synchrotron and compact light sources. This group has extensive experience in these types of studies at the SPring-8 and Australian synchrotrons, as well as the Munich Compact Light Source. These experimental settings produce unique challenges. Experiments are always performed in an isolated radiation enclosure not specifically designed for live-animal imaging. This requires equipment adapted to physiological monitoring and test-substance delivery, as well as shuttering to reduce the radiation dose. Experiment designs must also take into account the fixed location, size and orientation of the X-ray beam. This article describes the techniques developed to overcome the challenges involved in respiratory X-ray imaging of live animals at synchrotrons, now enabling increasingly sophisticated imaging protocols.


2019 ◽  
Vol 59 (1) ◽  
pp. 111-120 ◽  
Author(s):  
Annique C. Dombrowsky ◽  
Karin Burger ◽  
Ann-Kristin Porth ◽  
Marlon Stein ◽  
Martin Dierolf ◽  
...  

Author(s):  
Kaye Morgan ◽  
Regine Gradl ◽  
Martin Dierolf ◽  
Christoph Jud ◽  
Benedikt Günther ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Stephanie Kulpe ◽  
Martin Dierolf ◽  
Benedikt Günther ◽  
Madleen Busse ◽  
Klaus Achterhold ◽  
...  

Abstract In clinical diagnosis, X-ray computed tomography (CT) is one of the most important imaging techniques. Yet, this method lacks the ability to differentiate similarly absorbing substances like commonly used iodine contrast agent and calcium which is typically seen in calcifications, kidney stones and bones. K-edge subtraction (KES) imaging can help distinguish these materials by subtracting two CT scans recorded at different X-ray energies. So far, this method mostly relies on monochromatic X-rays produced at large synchrotron facilities. Here, we present the first proof-of-principle experiment of a filter-based KES CT method performed at a compact synchrotron X-ray source based on inverse-Compton scattering, the Munich Compact Light Source (MuCLS). It is shown that iodine contrast agent and calcium can be clearly separated to provide CT volumes only showing one of the two materials. These results demonstrate that KES CT at a compact synchrotron source can become an important tool in pre-clinical research.


Sign in / Sign up

Export Citation Format

Share Document