Prosthetic Rehabilitation of an External Auricle Defect With Silicone Rubber Using Extrinsic Staining

2013 ◽  
Vol 24 (3) ◽  
pp. e302-e305 ◽  
Author(s):  
Ting Sun ◽  
Longquan Shao ◽  
Yimin Zhao
2019 ◽  
Vol 18 (4) ◽  
pp. 538-549
Author(s):  
Sihama I Salih ◽  
Jawad K Oleiwi ◽  
Hajir M Ali

Many face organs are exposed to different environmental conditions in terms of different ofambient temperature, degradation, discoloration, changes in humidity and especiallyfrequent washing of these organs. These conditions cause changes in the structure ofmaterials so, for restoring the function and improving aesthetics of the affected areas ofmaxillofacial by surgical reconstruction and prosthetic rehabilitation the silicone rubbers(SR) and PMMA are the materials of choice. So that, the aim of this research is toinvestigate the effect of addition of polymethyl methacrylate (PMMA) material on thephysical properties of blends from SR/PMMA at different weight percentage (5%, 10%,15% and 20%) of PMMA to silicone rubber. Fourier transform infrared spectrometer test )FTIR(, density, water absorption and thermal properties were done on the all preparedsamples, which are used for maxillofacial prostheses applications. The results showed thatthere is good correlation in FTIR spectrum for reference silicone rubber and (SR/PMMA)polymer blend and this confer a good compatibility between silicone rubber matrix materialand PMMA. As well as the physical properties showed that the favorite percent of PMMA is10% which has ideal characteristic. So, this sample may be a suitable material to achieve theproperties required for maxillofacial prosthetic applications.


Author(s):  
Tim Oliver ◽  
Akira Ishihara ◽  
Ken Jacobsen ◽  
Micah Dembo

In order to better understand the distribution of cell traction forces generated by rapidly locomoting cells, we have applied a mathematical analysis to our modified silicone rubber traction assay, based on the plane stress Green’s function of linear elasticity. To achieve this, we made crosslinked silicone rubber films into which we incorporated many more latex beads than previously possible (Figs. 1 and 6), using a modified airbrush. These films could be deformed by fish keratocytes, were virtually drift-free, and showed better than a 90% elastic recovery to micromanipulation (data not shown). Video images of cells locomoting on these films were recorded. From a pair of images representing the undisturbed and stressed states of the film, we recorded the cell’s outline and the associated displacements of bead centroids using Image-1 (Fig. 1). Next, using our own software, a mesh of quadrilaterals was plotted (Fig. 2) to represent the cell outline and to superimpose on the outline a traction density distribution. The net displacement of each bead in the film was calculated from centroid data and displayed with the mesh outline (Fig. 3).


Author(s):  
Tim Oliver ◽  
Michelle Leonard ◽  
Juliet Lee ◽  
Akira Ishihara ◽  
Ken Jacobson

We are using video-enhanced light microscopy to investigate the pattern and magnitude of forces that fish keratocytes exert on flexible silicone rubber substrata. Our goal is a clearer understanding of the way molecular motors acting through the cytoskeleton co-ordinate their efforts into locomotion at cell velocities up to 1 μm/sec. Cell traction forces were previously observed as wrinkles(Fig.l) in strong silicone rubber films by Harris.(l) These forces are now measureable by two independant means.In the first of these assays, weakly crosslinked films are made, into which latex beads have been embedded.(Fig.2) These films report local cell-mediated traction forces as bead displacements in the plane of the film(Fig.3), which recover when the applied force is released. Calibrated flexible glass microneedles are then used to reproduce the translation of individual beads. We estimate the force required to distort these films to be 0.5 mdyne/μm of bead movement. Video-frame analysis of bead trajectories is providing data on the relative localisation, dissipation and kinetics of traction forces.


Author(s):  
Deepak D. ◽  
Nitesh Kumar ◽  
Shreyas P. Shetty ◽  
Saurabh Jain ◽  
Manoj Bhat

The expensive nature of currently used materials in the soft robotic industry demands the consideration of alternative materials for fabrication. This work investigates the performance of RTV-2 grade silicone rubber for fabrication of a soft actuator. Initially, a cylindrical actuator is fabricated using this material and its performance is experimentally assessed for different pressures. Further, parametric variations of the effect of wall thickness and inflation pressure are studied by numerical methods. Results show that, both wall thickness and inflation pressure are influential parameters which affect the elongation behaviour of the actuator. Thin (1.5 mm) sectioned actuators produced 76.97% more elongation compared to thick sectioned, but the stress induced is 89.61 % higher. Whereas, the thick sectioned actuator (6 mm) showed a higher load transmitting capability. With change in wall thickness from 1.5 mm to 6 mm, the elongation is reduced by 76.97 %, 38.35 %, 21.05 % and 11.43 % at pressure 100 kPa, 75 kPa, 50 kPa and 25 kPa respectively. The induced stress is also found reduced by 89.61 %, 86.66 %, 84.46 % and 68.68 % at these pressures. The average load carrying capacity of the actuator is found to be directly proportional to its wall thickness and inflation pressure.


2013 ◽  
Vol 133 (4) ◽  
pp. 205-210
Author(s):  
Norihito Oshikawa ◽  
Tatsuya Tokunaga ◽  
Kazufumi Honda ◽  
Takuma Miyake ◽  
Tatsuya Sakoda ◽  
...  

1985 ◽  
Vol 55 ◽  
Author(s):  
Miguel F. Refojo

ABSTRACTImplants are essential for the repair of retinal detachments. The implant buckles the wall of the eye and apposes the detached retina with the choroid, thus restoring light sensitivity to the retina. The scleral buckling also relieves traction on the retina from a shrinking vitreous body. The implant materials most commonly used are solid silicone rubber and silicone sponges, but both types have some disadvantages. A poly(hydroxyethyl acrylate-co-methyl acrylate) hydrogel implant with improved properties of softness and antibiotic absorption is also available for retinal detachment surgery. Proliferative vitreoretinopathy involves various conditions of retinal detachment complicated by vitreous fibrosis, which, after vitrectomy, may be treated with intraocular injection of fluids that support the retina against the choroid. For conditions requiring a long-term implant, silicone oil although controversial is the material of choice. Many other substances have been investigated but none better has yet been found.


Author(s):  
Marcela Moreira Salles ◽  
Viviane de Cássia Oliveira ◽  
Ana Paula Macedo ◽  
Claudia Helena Silva-Lovato ◽  
Helena de Freitas Oliveira Paranhos

Implant-supported prostheses hygiene and peri-implant tissues health are considered to be predictive factors for successful prosthetic rehabilitation. Therefore, the purpose of this study was to evaluate the effectiveness of brushing associated with oral irrigation measured as biofilm-removing capacity, maintenance of healthy oral tissues, and patient satisfaction. A randomized, crossover clinical trial was conducted with 38 patients who wore conventional maxillary complete dentures and mandibular overdentures retained by the O-ring system. The patients were instructed to use the following hygiene methods for 14 days: mechanical brushing [MB (brush and dentifrice - Control)]; and MB with oral irrigation [WP (Waterpik - Experimental)]. Biofilm-removing capacity and maintenance of healthy oral tissues were evaluated by the Modified Plaque Index (PI), Gingival Index (GI), Probing Depth (PD), and Bleeding on Probing Index (BP) recorded at baseline and after each method. In parallel, patients answered a specific questionnaire using a Visual Analogue Scale after each hygiene method. Data were analyzed by Friedman and Wilcoxon tests (α=0.05). The results showed significantly lower PI, GI, PD, and BP indices after application of the hygiene methods (P<0.001) than those observed at baseline. However, no significant difference was found between MB and WP. The satisfaction questionnaire responses to both methods showed high mean values for all questions, with no statistically significant difference found between the answers given after the use of MB and WP (P>0.05). The findings suggest that WP was effective in reducing PI, GI, PD, and BP indices and provided a high level of patient satisfaction.


Sign in / Sign up

Export Citation Format

Share Document