Clinical Observation of Single-Tooth Implant in the Deficient Anterior Maxilla With Intraoral Bone Grafts of Thin Periodontal Biotype Patients

2013 ◽  
Vol 24 (6) ◽  
pp. 2214-2217
Author(s):  
Xi Ding ◽  
Jun-hua Xu ◽  
Xing-hao Zhu ◽  
Hui-ming Wang
2006 ◽  
Vol 32 (6) ◽  
pp. 286-290 ◽  
Author(s):  
Jamil Awad Shibli ◽  
Susana d'Avila

Abstract Esthetic requirements for dental implant restoration have arisen in recent years. Despite several surgical techniques that have been developed, the treatment of the peri-implant soft-tissue defect is still difficult. The purpose of this clinical article is to describe a grafting technique using subepithelial connective tissue grafts to recontour soft-tissue margin discrepancy for single-tooth implant restorations in the anterior maxilla. After 2-year follow-up, this procedure shows that the use of connective tissue grafts can be a predictable approach to establish new and stable peri-implant soft-tissue margin.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
D. Baldi ◽  
J. Colombo ◽  
F. Motta ◽  
F. M. Motta ◽  
A. Zillio ◽  
...  

Replacing a single tooth in the anterior maxilla is one of the greatest challenges in dentistry. Both functional and aesthetic results are to be strictly pursued. Planning and executing such a case through a totally digital methodology eventually guarantee many advantages, above all patient’s operative and postoperative comfort. To ascertain this, a BOP analysis was performed which allowed us to evaluate soft tissues health, and more; crestal bone resorption was measured to evaluate hard tissues stability. This assumption was studied through four cases in which patients were alternatively treated with analogic and digital techniques. Four homogeneous patients were recruited. They all needed to extract one of the upper incisors, due to different clinical reasons, and then to replace it with an implant. Each patient was treated with an immediate postextractive implant which was immediately loaded, and finally, analogical and digital techniques were compared. All patients underwent a preoperative CBCT examination. After surgery, patients were checked by the surgeon after 10 days and one month to evaluate the progress of healing and to exclude any prosthetic problem. At 6 months (T1), one year (T2), and three years (T3), intraoral x-rays were performed using customized centring devices, according to the parallel beam technique. All data have been collected in a table and statistically processed; mean and standard deviation were measured. All patients entered an oral hygiene program with six months recall. Dental hygienist checked the BOP at T1, T2, and T3. At every step, similar levels of BOP were recorded. About interproximal bone loss, all patients showed an initial moderate loss (between T1 and T2), followed by stable values between T2 and T3. Despite the important limitations of a study with few cases, these results show a similar outcome comparing digital and analogical methods.


2011 ◽  
Vol 24 ◽  
pp. 88-93 ◽  
Author(s):  
M. Hof ◽  
B. Pommer ◽  
G. D. Strbac ◽  
D. Sütö ◽  
G. Watzek ◽  
...  

2021 ◽  
Vol 12 (2) ◽  
pp. 35
Author(s):  
Livia Nastri ◽  
Ludovica Nucci ◽  
Vincenzo Grassia ◽  
Rino Miraldi

Single tooth implant restorations in the aesthetic area are a demanding challenge. If a complete osseointegration is mandatory, the final result has to result in a higher standard of biomimetic and soft tissue health among natural teeth. This outcome is traditionally pursued by cementing crowns over individualized abutments. However, in recent years, the need for controlling peri-implant health and the preference towards a retrievable solution has led to an increase in screw-retained crowns, which is not always applicable when the implant axis is not ideal. In the aesthetic area, the use of a novel technical solution represented by the angled screw channel (ASC) of the abutment has been proposed in order to match the advantages of the screwed solution with the aesthetic demands. The aim of this study was to compare ASC crowns to cemented crowns (CC) in single implant restorations using the white esthetic score (WES) and pink esthetic score (PES) at the crown delivery and at a follow-up of a minimum of 2 years. Peri-implant health and marginal bone loss (MBL) were also evaluated. The mean follow-up was 44.3 months, with a mean MBL of 0.22 mm in the ASC group and 0.29 mm in the CC group. The total WES/PES score was 16.6 for ASC, compared with 17.3 for CC at baseline, and 16.2 and 17.1, respectively, at follow-up. Both of the groups reached a high WES/PES, and this was maintained over time, without signs of peri-implant diseases or bone loss, regardless of the choice of connection. In conclusion, ASC can be adopted in cases where the implant axis is not ideal, with aesthetic and functional results that are comparable to implants restored by cemented crowns.


Sign in / Sign up

Export Citation Format

Share Document