scholarly journals X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy

2016 ◽  
Vol 23 (5) ◽  
pp. 1180-1190 ◽  
Author(s):  
Pauline Fournier ◽  
Iwan Cornelius ◽  
Mattia Donzelli ◽  
Herwig Requardt ◽  
Christian Nemoz ◽  
...  

Microbeam radiation therapy (MRT) is a novel irradiation technique for brain tumours treatment currently under development at the European Synchrotron Radiation Facility in Grenoble, France. The technique is based on the spatial fractionation of a highly brilliant synchrotron X-ray beam into an array of microbeams using a multi-slit collimator (MSC). After promising pre-clinical results, veterinary trials have recently commenced requiring the need for dedicated quality assurance (QA) procedures. The quality of MRT treatment demands reproducible and precise spatial fractionation of the incoming synchrotron beam. The intensity profile of the microbeams must also be quickly and quantitatively characterized prior to each treatment for comparison with that used for input to the dose-planning calculations. The Centre for Medical Radiation Physics (University of Wollongong, Australia) has developed an X-ray treatment monitoring system (X-Tream) which incorporates a high-spatial-resolution silicon strip detector (SSD) specifically designed for MRT. In-air measurements of the horizontal profile of the intrinsic microbeam X-ray field in order to determine the relative intensity of each microbeam are presented, and the alignment of the MSC is also assessed. The results show that the SSD is able to resolve individual microbeams which therefore provides invaluable QA of the horizontal field size and microbeam number and shape. They also demonstrate that the SSD used in the X-Tream system is very sensitive to any small misalignment of the MSC. In order to allow as rapid QA as possible, a fast alignment procedure of the SSD based on X-ray imaging with a low-intensity low-energy beam has been developed and is presented in this publication.

2017 ◽  
Vol 24 (4) ◽  
pp. 866-876 ◽  
Author(s):  
Matthew Cameron ◽  
Iwan Cornelius ◽  
Dean Cutajar ◽  
Jeremy Davis ◽  
Anatoly Rosenfeld ◽  
...  

Microbeam radiation therapy (MRT) is a promising radiotherapy modality that uses arrays of spatially fractionated micrometre-sized beams of synchrotron radiation to irradiate tumours. Routine dosimetry quality assurance (QA) prior to treatment is necessary to identify any changes in beam condition from the treatment plan, and is undertaken using solid homogeneous phantoms. Solid phantoms are designed for, and routinely used in, megavoltage X-ray beam radiation therapy. These solid phantoms are not necessarily designed to be water-equivalent at low X-ray energies, and therefore may not be suitable for MRT QA. This work quantitatively determines the most appropriate solid phantom to use in dosimetric MRT QA. Simulated dose profiles of various phantom materials were compared with those calculated in water under the same conditions. The phantoms under consideration were RMI457 Solid Water (Gammex-RMI, Middleton, WI, USA), Plastic Water (CIRS, Norfolk, VA, USA), Plastic Water DT (CIRS, Norfolk, VA, USA), PAGAT (CIRS, Norfolk, VA, USA), RW3 Solid Phantom (PTW Freiburg, Freiburg, Germany), PMMA, Virtual Water (Med-Cal, Verona, WI, USA) and Perspex. RMI457 Solid Water and Virtual Water were found to be the best approximations for water in MRT dosimetry (within ±3% deviation in peak and 6% in valley). RW3 and Plastic Water DT approximate the relative dose distribution in water (within ±3% deviation in the peak and 5% in the valley). PAGAT, PMMA, Perspex and Plastic Water are not recommended to be used as phantoms for MRT QA, due to dosimetric discrepancies greater than 5%.


2019 ◽  
Vol 65 ◽  
pp. 227-237
Author(s):  
Alexandre Ocadiz ◽  
Jayde Livingstone ◽  
Mattia Donzelli ◽  
Stefan Bartzsch ◽  
Christian Nemoz ◽  
...  

2020 ◽  
Vol 14 ◽  
pp. 74-81
Author(s):  
Johanna Winter ◽  
Marek Galek ◽  
Christoph Matejcek ◽  
Jan J. Wilkens ◽  
Kurt Aulenbacher ◽  
...  

2016 ◽  
Vol 16 (1) ◽  
pp. 45-56 ◽  
Author(s):  
Sunil Sharma ◽  
Ganesh Narayanasamy ◽  
Beata Przybyla ◽  
Jessica Webber ◽  
Marjan Boerma ◽  
...  

We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made “gantry” and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.


2012 ◽  
Vol 112 (7) ◽  
pp. 073108 ◽  
Author(s):  
Shahrzad Vahedi ◽  
Go Okada ◽  
Brian Morrell ◽  
Edward Muzar ◽  
Cyril Koughia ◽  
...  

2010 ◽  
Vol 55 (15) ◽  
pp. 4375-4388 ◽  
Author(s):  
I Martínez-Rovira ◽  
J Sempau ◽  
J M Fernández-Varea ◽  
A Bravin ◽  
Y Prezado

2003 ◽  
Vol 30 (4) ◽  
pp. 583-589 ◽  
Author(s):  
E. Bräuer-Krisch ◽  
A. Bravin ◽  
M. Lerch ◽  
A. Rosenfeld ◽  
J. Stepanek ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document