Research on digital optical fiber current transformer with CT power supply

Author(s):  
Li Kaicheng ◽  
Hu Weibing ◽  
Liu Jianfeng ◽  
Zhang Ming
2004 ◽  
Vol 45 (2) ◽  
pp. 59-63 ◽  
Author(s):  
Masami HINO ◽  
Shinichi HASE ◽  
Kohji AJIKI ◽  
Masataka AKAGI

2008 ◽  
Author(s):  
Danping Jia ◽  
Ting Jia ◽  
Liang He ◽  
Yingwen Lin

2012 ◽  
Vol 7 (2) ◽  
pp. 128-131 ◽  
Author(s):  
Danping Jia ◽  
Zhuo Yuan ◽  
Wei Lin ◽  
Hongli San

2019 ◽  
Vol 14 (11) ◽  
pp. 1606-1615
Author(s):  
Jicheng Yu ◽  
Changxi Yue ◽  
Jun Li ◽  
Dengyun Li ◽  
He Li

Current transformer is one of the main equipment in ±10 kV DC distribution network. Traditional electromagnetic current transformer has poor anti-jamming capacity and poor insulation, so it cannot realize transient protection. The emergence of all-optical fiber current transformer brings solutions to these problems, which has attracted more and more attention. In this study, aiming at the problem of error and compensation of λ/4 waveform of all-fiber current transformer, the fabrication method of λ/4 waveform is studied, the mathematical model of the waveform is established, the influence of the waveform error on the scale factor is analyzed, and a calculating device of angle difference and ratio difference to compare the error is designed. The device adopts the principle of traceability of quantities to collect the state data of the wave plate. At the same time, in order to collect data for errors, database technology and network technology are used to realize remote transmission of monitoring data. The error of the λ/4 wave plate is compensated, the bidirectional principle generated by the birefringence in the fiber ring is analyzed, and the data logic description of the transformer sensitive ring is performed. The phase delay and the angle of the shaft are selected as the main factors causing the error. Compensation is performed by means of peak segmentation and variable cancellation. In the experimental process, compared with the error sampling of the traditional transformer, the error calculated by the current amplitude and phase angle parameters obtained by the all-fiber current transformer is more accurate, and the compensation scheme can suppress the size of the birefringence and improve sensing accuracy of fiber optic current transformers. This study provides a powerful reference for the error analysis of all-fiber current transformer λ/4 wave plates, which is beneficial to promote the better application of such current transformers.


2012 ◽  
Vol 462 ◽  
pp. 860-865
Author(s):  
Ming Bo Yang ◽  
Zi Ze Liang ◽  
En Li ◽  
Kai Liang Zhang ◽  
Guo Dong Yang

In order to prolong continuous working time of one transmission line inspection robot, a power supply system with induction charging unit for this inspection robot is introduced in this paper. Special current transformer by which the robot could get power from power line is designed according to the magnetic field condition around the transmission line. Besides, charging circuit for Li-battery pack is also introduced. A fly-back circuit is applied in the circuit to provide precisely accessible input power for charging battery packs. Experimental results show that the power supply system could have good performance on extending the continuous working period of the transmission line inspection robot.


2015 ◽  
Vol 30 (1) ◽  
pp. 184-192 ◽  
Author(s):  
Chin-Tien Liang ◽  
Kun-Long Chen ◽  
Yuan-Pin Tsai ◽  
Nanming Chen

Sign in / Sign up

Export Citation Format

Share Document