2014 ◽  
Vol 2014 ◽  
pp. 1-15 ◽  
Author(s):  
Radu Boriga ◽  
Ana Cristina Dăscălescu ◽  
Adrian-Viorel Diaconu

We present a new one-dimensional chaotic map, suitable for real-time image encryption. Its theoretical analysis, performed using some specific tools from the chaos theory, shows that the proposed map has a chaotic regime and proves its ergodicity, for a large space of values of the control parameter. In addition, to argue for the good cryptographic properties of the proposed map, we have tested the randomness of the values generated by its orbit using NIST statistical suite. Moreover, we present a new image encryption scheme with a classic bimodular architecture, in which the confusion and the diffusion are assured by means of two maps of the previously proposed type. The very good cryptographic performances of the proposed scheme are proved by an extensive analysis, which was performed regarding the latest methodology in this field.


2020 ◽  
Vol 8 (Suppl 3) ◽  
pp. A422-A422
Author(s):  
Ravi Murthy ◽  
Rahul Sheth ◽  
Alda Tam ◽  
Sanjay Gupta ◽  
Vivek Subbiah ◽  
...  

BackgroundImage guided intra-tumor administration of investigational immunotherapeutic agents represents an expanding field of interest. We present a retrospective review of the safety, feasibility & technical nuances of real-time image guidance for injection & biopsy across a spectrum of extracranial solid malignancies utilizing the discipline of Interventional Radiology.MethodsPatients who were enrolled in image guided intratumoral immunotherapy injection (ITITI) clinical trials over a 6 year period (2013–19) at a single tertiary care cancer center were included in this analysis. Malignancy, location, imaging guidance utilized for ITITI & biopsy for injected (adscopal) & non-injected (abscopal) lesions were determined and categorized. Peri-procedural adverse events were noted.Results262 pts (146 female, 61 yrs median) participating in 29 immunotherapeutic clinical trials (TLR & STING agonists, gene therapy, anti CD-40, viral/bacterial/metabolic oncolytics) met study criteria. Malignancies included melanoma 88, sarcoma 32, colorectal 29, breast 23, lung 17, head & neck 15, ovarian 8, neuroendocrine 7, pancreatic adenocarcinoma 6, 3 each (cholangioCA, endometrial, bladder, GI tract), 2 each (RCC, thymicCA, lymphoma, merkel cell, prostate) & others 1 each (CUP, GIST, dermatofibrosarcoma, DSRT, neuroblastoma, thyroid). All 169 & 93 patients received the intended 1371 ITITI in parietal (abdominal/chest wall, extremity, neck, pelvis) or visceral (liver, lung, peritoneum, adrenal) locations respectively; 83 patients received lymph node injections within either location. Imaging guidance was US in 68% of the cohort (US 161, CT+US 19); CT was used in 30% (81) & MRI in 1 patient. Median diameter of the ITITI lesion was 32 mm (8–230 mm). Median volume of the ITITI therapeutic material/session was 2 ml (1–6.9 ml). Lesions were accessed using a coaxial technique. ITITI delivery needles used at operator preference & tailored to lesion characteristics were either a 21G/22G Chiba, 21G Profusion (Cook Medical), 22G Morrison (AprioMed), 25G hypodermic (BD) & 18G Quadrafuse (Rex Medical). 2840 core biopsies (>18G Tru-cut core, Mission, Bard Medical) were performed in 237 patients during 690 procedures; biopsy sessions were often concurrent & of the ITITI site. 137 patients also underwent biopsy of a non-ITITI site (89 parietal location). Dimensions of the non-ITITI lesion were median 10 mm (7–113 mm); US image guidance was used in 97 patients (72%) to obtain a total of 1257, >18G Tru-core samples. 1.3% of injections resulted in SAE (NCI CTC AE >3) and 0.5% of 4097 biopsies developed major complications (SIR Criteria); both categories were manageable.ConclusionsUtilizing real time image guidance, ITITI to the administration of a myriad of investigational immunotherapeutic agents with concomitant biopsy procedures to date are associated with a high technical success rate & favorable safety profile.AcknowledgementsJoshua Hein, Mara Castaneda, Jyotsna Pera, Yunfang Jiang,Shuang Liu, Holly Liu and Anna LuiTrial RegistrationN/AEthics ApprovalThe study was approved by Institution’s Ethics Board, approval number 2020-0536: A retrospective study to determine the safety, feasibility and technical challenges of real-time image guidance for intra-tumor injection and biopsy across multiple solid tumors.Consent2020-0536 Waiver of Informed ConsentReferenceSheth RA, Murthy R, Hong DS, et al. Assessment of image-guided intratumoral delivery of immunotherapeutics in patients with cancer. JAMA Netw Open 2020;3(7):e207911. doi:10.1001/jamanetworkopen.2020.7911


Sign in / Sign up

Export Citation Format

Share Document