Research on self-powered short-circuit fault alarming system in power grid

Author(s):  
Shulin Liu ◽  
Dandan Xu
2013 ◽  
Vol 273 ◽  
pp. 389-393
Author(s):  
Yu Mei Wang ◽  
Xu Yang ◽  
Hao Zhang

When the power supply system for coal mine underground take place a short circuit fault, multilevel switch often respond at the same time. And the existing comprehensive protector cannot satisfy the real-time and rapid quality requirements of preventing override trip system for high-voltage power grid of coal mine underground. So this paper put forward the research for comprehensive protector of preventing override trip based on the EtherCAT. This paper first analyzes the principle and characteristics of the EtherCAT technology; and then puts forward the overall scheme of preventing override trip system; Finally, study and design the slave station and master station of preventing override trip system based on the EtherCAT.


2021 ◽  
Vol 11 (19) ◽  
pp. 9205
Author(s):  
Honggang Pan ◽  
Yunshi Wu ◽  
Zhiyuan Pang ◽  
Yanming Fu ◽  
Tianyu Zhao

Taking a 1000 MW turbine generator as the research object, the short-circuit fault in electrical disturbance is analyzed. Since it is very difficult to carry out fault analysis experiments and research on actual systems, simulation analysis is one of the more effective means of electrical fault diagnosis; the simulation’s results approach the actual behavior of the system and are ideal tools for power system analysis, and can provide an empirical basis for practical applications. The short-circuit fault model of the SIMULINK power system is built to analyze the two types of faults of generator terminals short-circuit and power grid short-circuit. The impact load spectrum, fault current and speed fluctuation between low-voltage rotors were extracted and analyzed. The conclusion is that the impact value of electromagnetic torque at the generator terminal is greater than that on the power grid side. The impact value of a two-phase short-circuit at the generator terminal is the largest, and that of a three-phase short-circuit on the power grid side is the smallest. The transient impulse current of a three-phase short-circuit at any fault point is greater than that of a two-phase short-circuit; the impulse current of the grid side short-circuit is much greater than that of the generator terminal short-circuit; the speed fluctuation and fluctuation difference caused by the three-phase short-circuit in the grid side are the largest. The alternating frequency of the transient electromagnetic force of the four kinds of faults avoids the natural frequency of the torsional vibration of the shaft system, and the torsional resonance of the shaft system in the time domain of the short-circuit fault will not appear. However, after the fault is removed, the residual small fluctuation torque in the system has a potential impact on the rotor system. This research shows an analysis of the structural integrity and safe operation of turbine generator units after a short-circuit fault, which can not only be applied to engineering practice, but also provide a theoretical basis for subsequent research.


2021 ◽  
Vol 9 ◽  
Author(s):  
Jun Xu ◽  
Lei Gao ◽  
Huiyuan Zhang

Abstract-Fault current limiters (FCLs) can suppress the rise of short-circuit fault currents in voltage source converter (VSC) based DC grids. However, the power electronic switches of FCLs need extra source equipment to supply the required power, which increases complexity and cost. This paper presents three kinds of self-powered solid-state FCLs (SSFCLs). The proposed self-powered SSFCLs detect short-circuit faults by sensing fault current increases and draw energy from the fault DC line to automatically drive the power electronic switches. The self-powered SSFCLs are equipped with a self-powered supply system (SPSS). The SPSS obtains energy from the magnetic field induced by short-circuit fault current using magnetic-coupling mutual inductance coils. In PSCAD/EMTDC, the proposed self-powered SSFCLs are placed directly on the DC line without external power supply equipment. When a short-circuit fault occurs, the simulation results verify that the proposed self-powered SSFCLs can rapidly acquire power to drive the power electronic switches and then suppress the rise of the fault current. The proposed self-powered SSFCL prototypes provide a solution for decreasing the cost and complexity associated with installing extra source equipment.


2019 ◽  
Vol 9 ◽  
pp. 22-29
Author(s):  
Yury Ya. LYAMETS ◽  
◽  
Mikhail V. MARTYNOV ◽  
Alexander N. MASLOV ◽  
◽  
...  

2019 ◽  
Vol 11 ◽  
pp. 33-39
Author(s):  
Yury Ya. LYAMETS ◽  
◽  
Mikhail V. MARTYNOV ◽  
Alexander N. MASLOV ◽  
◽  
...  

2019 ◽  
Vol 5 (5) ◽  
pp. 19-23
Author(s):  
Leonid A. GERMAN ◽  
◽  
Alexandr S. SEREBRYAKOV ◽  
Aleksey B. LOSKUTOV ◽  
Vladimir L. OSOKIN ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document