Approach to solve synthetic test circuit for testing of high voltage circuit breaker

Author(s):  
Vishal Kumar Gaur ◽  
H. R. Jariwala
Author(s):  
Jagadeesh Peddapudi, Et. al.

The most basic transient a circuit breaker needs to suffer during its activity is the transient recovery voltage (TRV), started by the electric force system as a characteristic response on flow interference. To test high voltage CBs, direct testing utilizing the force system or short out alternators are not practical. The testing of high voltage Circuit Breakers (CBs) of bigger limit requires huge limit of testing station. An equal infusion of short out current and transient voltage to medium and high voltage circuit breaker (CB) by a synthetic model is examined. Transient recovery voltage is made by a capacitor bank and is applied to CB. An optical set off spark gap has been utilized to interrupt short circuit and to introduce of transient recovery voltage that is applied across the contacts of circuit breaker. Transient recovery voltage examination can never be done totally, as the advancement of circuit breaker development and organization configuration goes on. The most widely recognized way to deal with TRV examination is concerning the supposed planned TRV, in which a suspicion of dismissing association between circuit breaker itself and the innate system recovery voltage is being made. Notwithstanding, it actually is by all accounts qualified to examine what circuit breaker means for transient recovery voltage. An ideal grouping to open/close of reinforcement test article and helper circuit breakers inside suitable chance to infuse of recovery voltage. The impact of reactance of inductive flaw current limiter just as distance to blame in short line issue condition on pace of ascent of recovery voltage. A 4-boundaries TRV synthetic test circuit dependent on equal current infusion technique is planned and mimicked for testing 145kV rating circuit-breakers according to new TRV prerequisites given in IEC 62271-100.


2013 ◽  
Vol 380-384 ◽  
pp. 3213-3216
Author(s):  
Hai Yan Wang ◽  
Duan Lei Yuan ◽  
Chen Xu Niu ◽  
Hua Jun Dong

In this paper, mainly for the problem that high voltage circuit breaker closing at the random phase can bring hard harmfulness to the power system. We design the 35kV SF6-Phase Control circuit breaker can control speed smartly, and opens or closes with phase selection, which is equipped with the magnetic actuator. In the article, the static and transient simulation analysis which includes the load force, and carried out prototype trial and test validation. At last, the results of simulation and test is given.


Sign in / Sign up

Export Citation Format

Share Document