Prevention of slot discharge and on-line condition monitoring of high voltage machine insulation

2003 ◽  
Author(s):  
A. Basu
2005 ◽  
Vol 293-294 ◽  
pp. 365-372 ◽  
Author(s):  
Yong Yong He ◽  
Wen Xiu Lu ◽  
Fu Lei Chu

The steam turboset is the key equipment of the electric power system. Thus, it is very important and necessary to monitor and diagnose the running condition and the faults of the steam turboset for the safe and normal running of the electric power system. In this paper, the Internet/Intranet based remote condition monitoring and fault diagnosis scheme is proposed. The corresponding technique and methods are discussed in detail. And a real application system is developed for the 300MW steam turboset. In this scheme, the system is built on the Internet/Intranet and the Client/Server construction and Web/Server model are adopted. The proposed scheme can guarantee real-time data acquisition and on-line condition analysis simultaneously. And especially, the remote condition monitoring and fault diagnosis can be implemented effectively. The developed system has been installed in a power plant of China. And the plant has obtained great economic benefits from it.


Author(s):  
Emran Md Amin ◽  
Nemai Chandra Karmakar

A novel approach for non-invasive radiometric Partial Discharge (PD) detection and localization of faulty power apparatuses in switchyards using Chipless Radio Frequency Identification (RFID) based sensor is presented. The sensor integrates temperature sensing together with PD detection to assist on-line automated condition monitoring of high voltage equipment. The sensor is a multi-resonator based passive circuit with two antennas for reception of PD signal from the source and transmission of the captured PD to the base station. The sensor captures PD signal, processes it with designated spectral signatures as identification data bits, incorporates temperature information, and retransmits the data with PD signals to the base station. Analyzing the PD signal in the base station, both the PD levels and temperature of a particular faulty source can be retrieved. The prototype sensor was designed, fabricated, and tested for performance analysis. Results verify that the sensor is capable of identifying different sources at the events of PD. The proposed low cost passive RFID based PD sensor has a major advantage over existing condition monitoring techniques due to its scalability to large substations for mass deployment.


Author(s):  
Jung Taek Kim ◽  
Seung Hwan Seong ◽  
J.H. Park ◽  
S.W. Cheon ◽  
C.K. Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document