Heater plate design for voltage endurance testing

Author(s):  
J.E. Timperley ◽  
J.D. Mandeville
2005 ◽  
Vol 33 (3) ◽  
pp. 156-178 ◽  
Author(s):  
T. J. LaClair ◽  
C. Zarak

Abstract Operating temperature is critical to the endurance life of a tire. Fundamental differences between operations of a tire on a flat surface, as experienced in normal highway use, and on a cylindrical test drum may result in a substantially higher tire temperature in the latter case. Nonetheless, cylindrical road wheels are widely used in the industry for tire endurance testing. This paper discusses the important effects of surface curvature on truck tire endurance testing and highlights the impact that curvature has on tire operating temperature. Temperature measurements made during testing on flat and curved surfaces under a range of load, pressure and speed conditions are presented. New tires and re-treaded tires of the same casing construction were evaluated to determine the effect that the tread rubber and pattern have on operating temperatures on the flat and curved test surfaces. The results of this study are used to suggest conditions on a road wheel that provide highway-equivalent operating conditions for truck tire endurance testing.


Eye ◽  
2021 ◽  
Author(s):  
Inês C. F. Pereira ◽  
Rosanne van de Wijdeven ◽  
Hans M. Wyss ◽  
Henny J. M. Beckers ◽  
Jaap M. J. den Toonder

AbstractGlaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS® implant and the new minimally invasive glaucoma surgery (MIGS) devices. In this review, we will describe each implant in detail, focusing on their efficacy in reducing IOP and safety profile. Additionally, a critical and evidence-based comparison between these implants will be provided. Finally, we will propose potential developments that may help to improve the performance of current devices.


2020 ◽  
Vol 34 (7) ◽  
pp. 8857-8863
Author(s):  
Yongfeng Liu ◽  
Shijie Bai ◽  
Ping Wei ◽  
Pucheng Pei ◽  
Shengzhuo Yao ◽  
...  

2013 ◽  
Vol 91 ◽  
pp. 187-193 ◽  
Author(s):  
David Krejci ◽  
Bernhard Seifert ◽  
Carsten Scharlemann

Sign in / Sign up

Export Citation Format

Share Document