The Improved Design Techniques of Comparator Performance

Author(s):  
Xiao Hu ◽  
Mai Ji ◽  
Ruiying Yang
Electronics ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 1311
Author(s):  
Giovanni Andrea Casula ◽  
Giuseppe Mazzarella ◽  
Giorgio Montisci ◽  
Giacomo Muntoni

Planar waveguide slot arrays (WSAs) have been used since 1940 and are currently used as performing antennas for high frequencies, especially in applications such as communication and RADAR systems. We present in this work a review of the most typical waveguide slot array configurations proposed in the literature, describing their main limitations and drawbacks along with possible effective countermeasures. Our attention has been focused mainly on the improved available design techniques to obtain high performance WSAs. In particular, the addressed topics have been reported in the following. Partially filled WSAs, or WSAs covered with single or multilayer dielectric slabs, are discussed. The most prominent second-order effects in the planar array feeding network are introduced and accurately modeled. The attention is focused on the T-junction feeding the array, on the effect of interaction between each slot coupler of the feeding network and the radiating slots nearest to this coupler, and on the waveguide bends. All these effects can critically increase the first sidelobes if compared to the ideal case, causing a sensible worsening in the performance of the array.


Author(s):  
W.K. Lo ◽  
J.C.H. Spence

An improved design for a combination Scanning Tunnelling Microscope/TEM specimen holder is presented. It is based on earlier versions which have been used to test the usefulness of such a device. As with the earlier versions, this holder is meant to replace the standard double-tilt specimen holder of an unmodified Philips 400T TEM. It allows the sample to be imaged simultaneously by both the STM and the TEM when the TEM is operated in the reflection mode (see figure 1).The resolution of a STM is determined by its tip radii as well as its stability. This places strict limitations on the mechanical stability of the tip with respect to the sample. In this STM the piezoelectric tube scanner is rigidly mounted inside the endcap of the STM holder. The tip coarse approach to the sample (z-direction) is provided by an Inchworm which is located outside the TEM vacuum.


Author(s):  
Zhiqiang Huang ◽  
Liyan Liu ◽  
Qin Li ◽  
Chengsong Qiu ◽  
Yachao Ma

Sign in / Sign up

Export Citation Format

Share Document