Analysis and performance improvement of solar PV system by solar irradiation tracking

Author(s):  
Akhilesh Kumar ◽  
Rupendra Kumar Pachauri ◽  
Yogesh K. Chauhan
2019 ◽  
Vol 11 (21) ◽  
pp. 67-74
Author(s):  
Imad Jawad Khadim

PV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building   220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficiency was 12%.


2019 ◽  
Vol 55 (1) ◽  
pp. 78-91 ◽  
Author(s):  
Subarni Pradhan ◽  
Ikhlaq Hussain ◽  
Bhim Singh ◽  
Bijaya Ketan Panigrahi

2021 ◽  
Author(s):  
Williams S. Ebhota ◽  
Pavel Y. Tabakov

Abstract A rooftop solar photovoltaic (PV) system is an alternative electricity source that is increasingly being used for households. The potential of solar PV is location dependent that needs to be assessed before installation. This study focuses on the assessment of a solar PV potential of a site on coordinates − 29.853762°, 031.00634°, at Glenmore Crescent, Durban North, South Africa. In addition, it evaluates the performance of a 6 kW installed capacity grid-connected rooftop solar PV system to supply electricity to a household. The results, obtained from PV design and simulation tools – PV*SOL, Solargis prospect and pvPlanner, were used to analyse and establish the site and PV system technical viability. The system’s configuration is as follows: load profile - a 2-Person household with 2-children, energy consumption − 3500 kWh, system size − 6 kWp, installation type - roof mount, PV module type - c-Si - monocrystalline silicon, efficiency − 18.9%, orientation of PV modules -Azimuth 0° and Tilt 30°, inverter 95.9% (Euro efficiency), and no transformer. The results show: meteorological parameters - global horizontal irradiation (GHI) 1659.3 kWh/m2, direct normal irradiation (DNI) 1610.6 kWh/m2, air temperature 20.6°C; performance parameters - annual PV energy 8639 kWh, Specific annual yield 1403 kWh/kWp, performance ratio (PR) 74.9%, avoided CO₂ emissions 5662 kg/year, and solar fraction 42.5 %. The analysis and benchmarking of the results show that the proposed solar PV system under the current conditions is technically viable for household electrification in Durban North, South Africa.


Author(s):  
Saminathan S & Dr. Ranjithkumar K

In this work, a new modular multilevel inverter topology is introduced for a single phase grid connected Photovoltaic system. This multilevel inverter use less number of switches to generate seven levels compared to other conventional multilevel inverters. This requires only one isolated dc source to operate. So it is suitable for renewable energy application. This inverter is designed by submodule configuration; each sub module contains two switches and one DC link capacitor. The sub modules will be added to the inverter depending on number of levels. The voltage balancing of DC link capacitor is carried out by Y matrix PWM technique. Because of Y matrix PWM technique, the inverter gets a self capacitor voltage balancing ability. So there is no need of external devices required for balancing the voltage of capacitor. A PLL for grid integration and LCL filter are designed and integrated with this inverter. The simulation of proposed system is carried out by MATLAB/SIMULINK and performance of THD is monitored as per standards


2016 ◽  
Vol 5 (1) ◽  
pp. 48-67 ◽  
Author(s):  
Michael White ◽  
Ahad Ali

With the greening of the US power grid most of the available landscape and resource investment lays with residential home owners. Historically homes were not built with green technology in mind. Roof faces do not always face south, nor are they always at optimum angles. Existing homes are often shaded by old growth trees. This paper covers decision-making tools for cost, performance, layout, and labor optimization. It also includes a case study from a residential solar PV system in suburbia Detroit, Michigan; and goes further into possible improvements to the system after initial installation and their cost effectiveness.


Sign in / Sign up

Export Citation Format

Share Document