The influence of the method of winding construction on metrological properties of current transformers designed for systems of monitoring of power quality

Author(s):  
Michal Kaczmarek ◽  
Ryszard Nowicz ◽  
Artur Szczesny ◽  
Krzysztof Pacholski
Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 2907
Author(s):  
Christian Laurano ◽  
Sergio Toscani ◽  
Michele Zanoni

Conventional current transformers (CTs) suffer from nonlinearities due to their ferromagnetic cores. On one hand, it is well-known that severe core saturation may occur because of large overcurrents or unidirectional transient components: this may substantially impact the operation of relays. On the other hand, weaker nonlinear effects are also present during regular working conditions. In particular, the spectral content of typical current waveforms is characterized by a strong fundamental term responsible for harmonic distortion affecting the frequency components at the secondary side. In turn, this has a significant impact on the accuracy that can be reached as long as current harmonics must be monitored. The target of this work is implementing a simple signal processing technique that allows compensating for this effect. The method, characterized by extremely low computational complexity, is first introduced and validated using numerical simulations. After this, it was tested experimentally to improve the harmonic measurement capability of inductive CTs. The achieved results highlight a noticeable reduction of errors at low-order harmonics over a wide range of primary current amplitudes. It is worth noting that the black-box approach makes the technique suitable also for compensating nonlinearities introduced by current transducers based on different operating principles. Thanks to this peculiarity and to the low computational complexity, the proposed method is suitable to be employed in power quality analyzers and merging units. In this way, high-accuracy monitoring of current harmonics in power systems can be achieved, opening the way to advanced power quality management and to the location of disturbing users.


1896 ◽  
Vol 42 (1084supp) ◽  
pp. 17330-17331
Author(s):  
J. A. Fleming

1945 ◽  
Vol 15 (60) ◽  
pp. 46
Author(s):  
A.R. Rumfitt
Keyword(s):  

2018 ◽  
Vol 1 (1) ◽  
pp. 54-66
Author(s):  
Rakan Khalil Antar ◽  
Basil Mohammed Saied ◽  
Rafid Ahmed Khalil

A new control strategy for active power filters is proposed, modeled and implemented in order to improve the power quality of a line commutated converter High voltage DC link. The ability of reactive power and harmonics reductions are generally met by using passive and active power filters. In this paper, modified active power filter with a modified harmonics pulse width modulation algorithm is used to minimize the source harmonics and force the AC supply current to be in the same phase with AC voltage source at both sending and receiving sides of a line commutated converter high voltage DC link. Therefore, it is considered as power factor corrector and harmonics eliminator with random variations in the load current. The modified harmonics pulse width modulation algorithm is applicable for active power filter based on a three-phase five-level and seven-level cascaded H-bridge voltage source inverter. Simulation results show that the suggested modified multilevel active power filters improve total harmonics distortion of both voltage and current with almost unity effective power factor at both AC sides of high voltage DC link. Therefore, modified active power filter is an effective tool for power quality improvement and preferable for line commutated converter high voltage DC link at different load conditions.


2015 ◽  
Vol 135 (5) ◽  
pp. 272-275
Author(s):  
Shoji Nishimura ◽  
Shigeru Inno ◽  
Tatsuki Okamoto

Author(s):  
Yuri Kolev ◽  
Атanas Atanasov ◽  
Таnia Pehlivanova

A load profile measuring device takes information about the power consumption without modification of the power lines. Using current transformers, the current is measured in each of the phases and the active power consumed by the user is determined. The developed software for it allows for simultaneous recording at different user selectable timing intervals. The device is designed and tested in two facilities - a School and a Farm.


Sign in / Sign up

Export Citation Format

Share Document