A signal quality assessment method for mobile ECG using multiple features and fuzzy support vector machine

Author(s):  
Yatao Zhang ◽  
Shoushui Wei ◽  
Li Zhang ◽  
Chengyu Liu
2010 ◽  
Vol 113-116 ◽  
pp. 708-711 ◽  
Author(s):  
Wei Guo Zhao ◽  
Li Ying Wang

It has been a more complex problem for water quality assessment. And its aim is to well and truly evaluate its degree of pollution for bodies of water, which will be easy to provide some principled projects and criterions for water resource’s protection and their integration application. So, a water quality assessment method based on Multiclass Fuzzy Support Vector Machine is put forward. and a two-step cross-validation was used to search for the best combination of parameters to obtain an optimal training model. The test results show that the method proposed in this paper has an excellent performance on correct ratio compared to BP. It indicated that the performance of the proposed model is practically feasible in the application of water quality assessment.


2021 ◽  
Vol 25 (1) ◽  
pp. 35-39
Author(s):  
Łukasz Glodek ◽  
Szymon Bysko ◽  
Witold Nocoń

This paper proposes a model quality assessment method based on Support Vector Machine, which can be used to develop a digital twin. This work is strongly connected with Industry 4.0, in which the main idea is to integrate machines, devices, systems, and IT. One of the goals of Industry 4.0 is to introduce flexible assortment changes. Virtual commissioning can be used to create a simulation model of a plant or conduct training for maintenance engineers. On a branch of virtual commissioning is a digital twin. The digital twin is a virtual representation of a plant or a device. Thanks to the digital twin, different scenarios can be analyzed to make the testing process less complicated and less time-consuming. The goal of this work is to propose a coefficient that will take into account expert knowledge and methods used for model quality assessment (such as Normalized Root Mean Square Error – NRMSE, Maximum Error – ME). NRMSE and ME methods are commonly used for this purpose, but they have not been used simultaneously so far. Each of them takes into consideration another aspect of a model. The coefficient allows deciding whether the model can be used for digital twin appliances. Such an attitude introduces the ability to test models automatically or in a semi-automatic way.


2018 ◽  
Vol 8 (9) ◽  
pp. 1757-1762 ◽  
Author(s):  
Jie Zhang ◽  
Licai Yang ◽  
Zhonghua Su ◽  
Xueqin Mao ◽  
Kan Luo ◽  
...  

Background: Noise is unavoidable in the physiological signal measurement system. Poor quality signals can affect the results of analysis and disable the following clinical diagnosis. Thus, it is necessary to perform signal quality assessment before we interpreting the signal. Objective: In this work, we describe a method combing support vector machine (SVM) and multi-feature fusion for assessing the signal quality of pulsatile waveforms, concentrating on the photoplethysmogram (PPG). Methods: PPG signals from 53 healthy volunteers were recorded. Each had a 5 min length. Signal quality in each heart beat was manual annotated by clinical expert, and then the signal quality in 5 s episode was automatically calculated according to the results from each beat segments, resulting in a total of 13,294 5-s PPG segments. Then a SVM was trained to classify clean/noisy PPG recordings by inputting a set of twelve signal quality features. Further experiments were carried out to verify the proposed SVM based signal quality classifier method. Results: An average accuracy of 87.90%, a sensitivity of 88.10% and a specificity of 87.66% were found on the 10-fold cross validation. Conclusions: The signal quality of PPGs can be accurately classified by using the proposed method.


Sign in / Sign up

Export Citation Format

Share Document