A low-cost automatic acquisition system for photogrammetry

Author(s):  
Leila Es Sebar ◽  
Sabrina Grassini ◽  
Marco Parvis ◽  
Luca Lombardo
Author(s):  
Cheyma BARKA ◽  
Hanen MESSAOUDI-ABID ◽  
Houda BEN ATTIA SETTHOM ◽  
Afef BENNANI-BEN ABDELGHANI ◽  
Ilhem SLAMA-BELKHODJA ◽  
...  

Sensors ◽  
2018 ◽  
Vol 18 (7) ◽  
pp. 2382 ◽  
Author(s):  
Antonio Vidal-Pardo ◽  
Santiago Pindado

In this work, a new and low-cost Arduino-Based Data Acquisition System (ABDAS) for use in an aerodynamics lab is developed. Its design is simple and reliable. The accuracy of the system has been checked by being directly compared with a commercial and high accuracy level hardware from National Instruments. Furthermore, ABDAS has been compared to the accredited calibration system in the IDR/UPM Institute, its measurements during this testing campaign being used to analyzed two different cup anemometer frequency determination procedures: counting pulses and the Fourier transform. The results indicate a more accurate transfer function of the cup anemometers when counting pulses procedure is used.


2010 ◽  
Vol 24 (S1) ◽  
Author(s):  
Lili Kudo ◽  
Tony Fields ◽  
Anatol Bragin ◽  
Stanislav L. Karsten ◽  
Nancy Vi

Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6075
Author(s):  
Guilherme Fonseca Bassous ◽  
Rodrigo Flora Calili ◽  
Carlos Hall Barbosa

The rising adoption of renewable energy sources means we must turn our eyes to limitations in traditional energy systems. Intermittency, if left unaddressed, may lead to several power-quality and energy-efficiency issues. The objective of this work is to develop a working tool to support photovoltaic energy forecast models for real-time operation applications. The current paradigm of intra-hour solar-power forecasting is to use image-based approaches to predict the state of cloud composition for short time horizons. Since the objective of intra-minute forecasting is to address high-frequency intermittency, data must provide information on and surrounding these events. For that purpose, acquisition by exception was chosen as the guiding principle. The system performs power measurements at 1 Hz frequency, and whenever it detects variations over a certain threshold, it saves the data 10 s before and 4 s after the detection point. A multilayer perceptron neural network was used to determine its relevance to the forecasting problem. With a thorough selection of attributes and network structures, the results show very low error with R2 greater than 0.93 for both input variables tested with a time horizon of 60 s. In conclusion, the data provided by the acquisition system yielded relevant information for forecasts up to 60 s ahead.


Author(s):  
Pedro Leineker Ochoski Machado ◽  
Luis Vitorio Gulineli Fachini ◽  
Vitor Otávio Ochoski Machado ◽  
Romeu Miqueias Szmoski ◽  
Thiago Antonini Alves

In the present work, an experimental analysis was performed to obtain the calibration curve of three load cells connected in series. The control of the load applied on a given component is an important factor in some engineering applications, for example, in cases where it is desired to increase the heat exchange between two surfaces. One of the ways to control the applied load is the use of load cells, which has as its principle of use a strain gauge that has its resistance varied when it undergoes a deformation, thus causing a voltage variation due to the application of load. This study used an ArduinoTM microcontroller as a data acquisition system and blocks with known mass for load application.  In this way it was possible to obtain the calibration curve of the load cells by means of linear regression between the mass of the blocks and the data obtained by the ArduinoTM microcontroller and verify their applicability according to their measurement uncertainties.


Sensors ◽  
2020 ◽  
Vol 20 (4) ◽  
pp. 1064
Author(s):  
Antonio C. Domínguez-Brito ◽  
Jorge Cabrera-Gámez ◽  
Manuel Viera-Pérez ◽  
Eduardo Rodríguez-Barrera ◽  
Luis Hernández-Calvento

Environmental studies on coastal dune systems are faced with a considerable cost barrier due to the cost of the instrumentation and sensory equipment required for data collection. These systems play an important role in coastal areas as a protection against erosion and as providers of stability to coastal sedimentary deposits. The DIY (Do-It-Yourself) approach to data acquisition can reduce the cost of these environmental studies. In this paper, a low-cost DIY wireless wind data acquisition system is presented which reduces the cost barrier inherent to these types of studies. The system is deployed for the analysis of the foredune of Maspalomas, an arid dune field situated on the south coast of Gran Canaria (Canary Islands, Spain), for the specific purpose of studying the dynamics of a dune type (tongue dunes), which is typical of this environment. The results obtained can be of interest for the study of these coastal environments at both the local level, for the management of this particular dune field, and at the general level for other similar dune fields around the world.


2020 ◽  
Vol 39 (7) ◽  
pp. 480-487
Author(s):  
Patrick Smith ◽  
Brandon Mattox

The P-Cable high-resolution 3D marine acquisition system tows many short, closely separated streamers behind a small source. It can provide 3D seismic data of very high temporal and spatial resolution. Since the system is containerized and has small dimensions, it can be deployed at short notice and relatively low cost, making it attractive for time-lapse seismic reservoir monitoring. During acquisition of a 3D high-resolution survey in the Gulf of Mexico in 2014, a pair of sail lines were repeated to form a time-lapse seismic test. We processed these in 2019 to evaluate their geometric and seismic repeatability. Geometric repetition accuracy was excellent, with source repositioning errors below 10 m and bin-based receiver positioning errors below 6.25 m. Seismic data comparisons showed normalized root-mean-square difference values below 10% between 40 and 150 Hz. Refinements to the acquisition system since 2014 are expected to further improve repeatability of the low-frequency components. Residual energy on 4D difference seismic data was low, and timing stability was good. We conclude that the acquisition system is well suited to time-lapse seismic surveying in areas where the reservoir and time-lapse seismic signal can be adequately imaged by small-source, short-offset, low-fold data.


Sign in / Sign up

Export Citation Format

Share Document