Adaptive Zone-Division AVC Method Based on Reactive Power Margin Evaluation for Wind Farm

Author(s):  
Yang-Wu Shen ◽  
Bin Zhang ◽  
Liqing Liang ◽  
Yushi Feng ◽  
Yu Rao ◽  
...  
2013 ◽  
Vol 756-759 ◽  
pp. 4171-4174 ◽  
Author(s):  
Xiao Ming Wang ◽  
Xing Xing Mu

With the Asynchronous wind generators as research object, this paper analyzes the problems of the voltage stability and the generation mechanism of the reactive power compensation during the wind farms connected operation. For paralleling capacitor bank has shown obvious defects, therefore this paper employs dynamic reactive power compensation to improve reactive characteristics of grid-connected wind farms. With the influences of different wind disturbances and grid faults on wind farms, wind farm model is set up and dynamic reactive power compensation system and wind speeds are built in the Matlab/Simulink software, The simulation result shows that they can provide reactive power compensation to ensure the voltage stability of the wind farms. But STATCOM needs less reactive compensation capacity to make sure the voltage and active power approaching steady state before the faults more quickly, Therefore STATCOM is more suitable for wind farms connected dynamic reactive power compensation.


2018 ◽  
Vol 8 (1) ◽  
pp. 68
Author(s):  
Seungmin Jung ◽  
Yeuntae Yoo ◽  
Taehyung Kim ◽  
Jae-Hyeong Lee ◽  
Minhan Yoon ◽  
...  

2021 ◽  
Vol 701 (1) ◽  
pp. 012083
Author(s):  
J F Wang ◽  
C F Chen ◽  
S Zhang ◽  
Z Ren ◽  
X L Chen ◽  
...  

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Asaad Shemshadi ◽  
Pourya Khorampour

Abstract In recent years, the use of wind energy to generate electricity in the world has been accelerating and growing. Wind farms are unstable when dynamic voltage fluctuations occur, especially sudden and sudden changes in load, and show oscillating performance at their output. In this paper, the Unified Power Flow Controller (UPFC) has been simulated and studied by Matlab software to improve the dynamic stability and transient behavior of the wind power plant in the event of sudden load changes. The simulation results show that by controlling the UPFC series inverter, voltage fluctuations in the PCC bus are prevented and the UPFC parallel inverter injects power after changing the load for faster recovery and stability of the PCC bus voltage and thus the stability of the wind farm. The UPFC can control the active and reactive power at the transmission line, and in fact, controls the output of the wind turbine with the generator from both sides to the fluctuations caused by sudden load changes that play a role such as sudden disturbances and oscillating errors. Also, the presence of UPFC in the system reduces power fluctuations.


2021 ◽  
Vol 233 ◽  
pp. 01025
Author(s):  
Yingfeng Zhu ◽  
Xiaosu Xie ◽  
Dong Yang ◽  
Song Gao ◽  
Weichao Zhang ◽  
...  

Doubly fed induction generator (DFIG) wind power generation system is widely used in wind farm all over the world. Reactive power can be generated both in grid-side converter and generator-side converter of DFIG. In this paper, working principle and control method of DFIG are introduced, and the reactive power limit of DFIG is derived, finally reactive power regulation is simulated in Simulink.


Sign in / Sign up

Export Citation Format

Share Document