Research on Moisture Content Evaluation Algorithm of Transformer Oil-Paper Insulation System

Author(s):  
Mingze ZHANG ◽  
Ji LIU ◽  
Pengshuai QI ◽  
Qingguo CHEN ◽  
Jialu LV ◽  
...  
2014 ◽  
Vol 644-650 ◽  
pp. 3548-3551 ◽  
Author(s):  
Jin Fu ◽  
Jian Hao ◽  
Hua Yin ◽  
Gao Lin Wu ◽  
Qian Wang

Moisture has a detrimental effect on oil-paper insulation life by lowering electrical breakdown strength. How does the space charge behavior of the oil-paper insulation system consisted by oil gap and oil immersed insulation pressboard with different moisture content? The space charge characteristics of the mixed insulation consisted of oil gap and pressboard with three moisture content were investigated using the PEA measurement system. The space charge accumulation behaviors at the interface between oil gap and pressboard were analyzed. The distortion of the electrical field in the oil gap and pressboard was also analyzed. Results show that there are many charges injected into the oil and the pressboard. The charges accumulated at the interface between oil gap and pressboard. The charges accumulated in the mixed insulation system become less with the moisture content increased. The difference of the electric field strength in the oil gap and pressboard become smaller with the moisture content increased.


Energies ◽  
2017 ◽  
Vol 10 (8) ◽  
pp. 1195 ◽  
Author(s):  
Guoqiang Xia ◽  
Guangning Wu ◽  
Bo Gao ◽  
Haojie Yin ◽  
Feibao Yang

2020 ◽  
Vol 7 (10) ◽  
pp. 369-374
Author(s):  
Yasir Khan ◽  
◽  
Muhammad Iftikhar Khan ◽  

Oil reclamation is a transformer insulation reconditioning technique which may be used as on-line or off-line. However, there is a need of evidence showing the effect of this process on conditions of the paper insulation, which indeed affects the life span of a transformer. This research work focuses on oil reclamation experiment on an old retired distribution transformer. Electrical testing and post-mortem analysis of the transformer were conducted, aimed at investigating the design aspects and collecting information on the insulation conditions prior to the oil reclamation. Temperature and moisture sensors were installed to monitor the conditions within the transformer during the oil reclamation [2]. The experimental process of transformer Oil reclamation was performed into two phases, with regular oil sampling to analyze the changes in key oil parameters, namely acidity number (AN), moisture and breakdown voltage (BV). This was accompanied by paper sampling at the end of each reclamation cycle to study the effects of oil reclamation on properties, particularly moisture, LMA and degree of polymerization. The transformer which was used for the entire experimental process was about 45 years old, 200kVA, 1100 / 415-240V distribution transformer. In order to study the long-term effect of oil reclamation, oil samples were collected from an on-site reclamation exercise performed in a laboratory-accelerated thermal ageing experiment. Oil samples collected before and after the reclamation were aged alongside new oils for comparison [4]. Through the regular monitoring and measurement of oil parameters (AN, moisture and BD strength) over 144 hours and paper parameters (LMA, moisture and DP) at specific stages of phase 1, it was observed that the transformer oil-paper insulation system was significantly improved. The entire research work was performed into two phases (phase 1 and phase 2). The “phase 1” was aimed to improve and restore the oil parameters comparable to the parameters of new oil as specified in “IEC-60296” and its effect on the paper insulation. “Phase 2” was aimed to compare the life span of reclaimed oil filled transformer with the transformer in which aged oil has been replaced by new oil[6]. Effective study of oil reclamation was analyzed through laboratory accelerated aging experiment and real time application on a 45 years old transformer. Through the regular monitoring and measurement of oil parameters (AN, moisture and BD strength) over 144 hours and paper parameters (LMA, moisture and DP) at specific stages of phase1, it was observed that the transformer oil-paper insulation system was significantly improved [15].


Sign in / Sign up

Export Citation Format

Share Document