Inverse method using infrared thermography for surface temperature and heat flux measurements

Author(s):  
P. Reulet ◽  
D. Nortershauser ◽  
P. Millan
Nukleonika ◽  
2015 ◽  
Vol 60 (2) ◽  
pp. 285-288 ◽  
Author(s):  
Yashashri Patil ◽  
S. Khirwadkar ◽  
S. M. Belsare ◽  
Rajamannar Swamy ◽  
M. S. Khan ◽  
...  

Abstract This paper is focused on various aspects of the development and testing of water cooled divertor PFCs. Divertor PFCs are mainly designed to absorb the heat and particle fluxes outflowing from the core plasma of fusion devices like ITER. The Divertor and First Wall Technology Development Division at the Institute for Plasma Research (IPR), India, is extensively working on development and testing of divertor plasma facing components (PFCs). Tungsten and graphite macro-brush type test mock-ups were produced using vacuum brazing furnace technique and tungsten monoblock type of test mock-ups were obtained by hot radial pressing (HRP) technique. Heat transfer performance of the developed test mock-ups was tested using high heat flux tests with different heat load conditions as well as the surface temperature monitoring using transient infrared thermography technique. Recently we have established the High Heat Flux Test Facility (HHFTF) at IPR with an electron gun EH300V (M/s Von Ardenne Anlagentechnik GmbH, Germany) having maximum power 200 kW. Two tungsten monoblock type test mock-ups were probed using HHFTF. Both of the test mock-ups successfully sustained 316 thermal cycles during high heat flux (HHF) tests. The test mock-ups were non-destructively tested using infrared thermography before and after the HHF tests. In this note we describe the detailed procedure used for testing macro-brush and monoblock type test mock-ups using in-house transient infrared thermography set-up. An acceptance criteria limit was defined for small scale macro-brush type of mock-ups using DTrefmax value and the surface temperature measured during the HHF tests. It is concluded that the heat transfer behavior of a plasma facing component was checked by the HHF tests followed by transient IR thermography. The acceptance criteria DTrefmax limit for a graphite macro-brush mock-up was found to be ~3°C while for a tungsten macro-brush mock-up it was ~5°C.


2007 ◽  
Vol 27 (14-15) ◽  
pp. 2463-2472 ◽  
Author(s):  
Patrik Wikström ◽  
Wlodzimierz Blasiak ◽  
Fredrik Berntsson

Author(s):  
Terry Hendricks ◽  
Jaal Ghandhi ◽  
John Brossman

Heat flux measurements were performed in an air-cooled utility engine using a fast-response coaxial-type surface thermocouple. The surface heat flux was calculated using both analytical and numerical models. The heat flux was found to be a strong function of engine load. The peak heat flux and initial heat flux rise rate increase with engine load. The measured heat flux data were used to estimate a global heat transfer rate, and this was compared with the heat transfer rate calculated by a single-zone heat release analysis. The measured values of heat transfer were higher than the calculated values largely because of the lack of spatial averaging. The high load data showed an unexplainable negative heat flux during the expansion stroke while the gas temperature was still high. A 1D and 2D finite difference numerical model utilizing an adaptive timestep Crank-Nicholson (CN) integration routine was developed to investigate the surface temperature measurement. Applying the measured surface temperature profile to the 1D model, the resultant surface heat flux showed excellent agreement with the analytical inversion solution and captured the reversal of the energy flow back into the cylinder during the expansion stroke. The 2D numerical model was developed to observe transient lateral conduction effects within the probe and incorporated the various materials used in the construction and assembly of the heat flux sensor. The resulting average heat flux profile for the test case is shown to be slightly higher in peak and longer in duration when compared with the results from the 1D analytical inversion, and this is attributed to contributions from the high thermal diffusivity constituents in the sensor. Furthermore, the negative heat flux at high load was not eliminated suggesting that factors other than lateral conduction may be affecting the measurement accuracy.


2021 ◽  
Vol 121 ◽  
pp. 110274
Author(s):  
Jens A. Rataczak ◽  
Carson L. Running ◽  
Thomas J. Juliano

Author(s):  
Caspar Ask Christiansen ◽  
Stefan Mayer ◽  
Jesper Schramm

Surface temperature measurements were performed in a large bore two-stroke diesel engine used for ship propulsion. A specially designed fast-response surface thermocouple was used together with an embedded standard K-type thermocouple to measure surface temperature and heat flux with high temporal resolution. Heat flux calculations were carried out both analytically and numerically showing good agreement between the results. Measurements were carried out at three different engine load conditions (25%, 30% and 50% load) in one of the fuel atomizers in the cylinder head. Cyclic surface temperature variations of up to approximately 80 K with a peak temperature of 860 K were observed. The magnitude of the perturbation of the temperature field due to the presence of the thermocouples was investigated by three dimensional CFD simulations.


Sign in / Sign up

Export Citation Format

Share Document