INFRARED THERMOGRAPHY FOR MEASURING THE SURFACE TEMPERATURE OF AN OXIDIC MELT

Author(s):  
Christophe Journeau ◽  
Claude Jegou ◽  
Gerard Cognet
2021 ◽  
Vol 13 (5) ◽  
pp. 957
Author(s):  
Guglielmo Grechi ◽  
Matteo Fiorucci ◽  
Gian Marco Marmoni ◽  
Salvatore Martino

The study of strain effects in thermally-forced rock masses has gathered growing interest from engineering geology researchers in the last decade. In this framework, digital photogrammetry and infrared thermography have become two of the most exploited remote surveying techniques in engineering geology applications because they can provide useful information concerning geomechanical and thermal conditions of these complex natural systems where the mechanical role of joints cannot be neglected. In this paper, a methodology is proposed for generating point clouds of rock masses prone to failure, combining the high geometric accuracy of RGB optical images and the thermal information derived by infrared thermography surveys. Multiple 3D thermal point clouds and a high-resolution RGB point cloud were separately generated and co-registered by acquiring thermograms at different times of the day and in different seasons using commercial software for Structure from Motion and point cloud analysis. Temperature attributes of thermal point clouds were merged with the reference high-resolution optical point cloud to obtain a composite 3D model storing accurate geometric information and multitemporal surface temperature distributions. The quality of merged point clouds was evaluated by comparing temperature distributions derived by 2D thermograms and 3D thermal models, with a view to estimating their accuracy in describing surface thermal fields. Moreover, a preliminary attempt was made to test the feasibility of this approach in investigating the thermal behavior of complex natural systems such as jointed rock masses by analyzing the spatial distribution and temporal evolution of surface temperature ranges under different climatic conditions. The obtained results show that despite the low resolution of the IR sensor, the geometric accuracy and the correspondence between 2D and 3D temperature measurements are high enough to consider 3D thermal point clouds suitable to describe surface temperature distributions and adequate for monitoring purposes of jointed rock mass.


2021 ◽  
Vol 11 (9) ◽  
pp. 3773
Author(s):  
Simone Mineo ◽  
Giovanna Pappalardo

Infrared thermography is a growing technology in the engineering geological field both for the remote survey of rock masses and as a laboratory tool for the non-destructive characterization of intact rock. In this latter case, its utility can be found either from a qualitative point of view, highlighting thermal contrasts on the rock surface, or from a quantitative point of view, involving the study of the surface temperature variations. Since the surface temperature of an object is proportional to its emissivity, the knowledge of this last value is crucial for the correct calibration of the instrument and for the achievement of reliable thermal outcomes. Although rock emissivity can be measured according to specific procedures, there is not always the time or possibility to carry out such measurements. Therefore, referring to reliable literature values is useful. In this frame, this paper aims at providing reference emissivity values belonging to 15 rock types among sedimentary, igneous and metamorphic categories, which underwent laboratory emissivity estimation by employing a high-sensitivity thermal camera. The results show that rocks can be defined as “emitters”, with emissivity generally ranging from 0.89 to 0.99. Such variability arises from both their intrinsic properties, such as the presence of pores and the different thermal behavior of minerals, and the surface conditions, such as polishing treatments for ornamental stones. The resulting emissivity values are reported and commented on herein for each different studied lithology, thus providing not only a reference dataset for practical use, but also laying the foundation for further scientific studies, also aimed at widening the rock aspects to investigate through IRT.


Author(s):  
Kennethrex O. Ndukaife ◽  
George Agbai Nnanna

An Infrared thermography (IRT) technique for characterization of fouling on membrane surface has been developed. The emitted spectral power from the fouled membrane is a function of emissivity and surface morphology. In this work, a FLIR A320 IR camera was used to measure surface temperature and emissivity. The surface temperature and the corresponding emissivity value of various areas on the fouled membrane surface is measured by the infrared camera and recorded alongside its thermogram. Different fouling experiments were performed using different concentrations of aluminum oxide nanoparticle mixed with deionized water as feed solution (333 ppm, 1833 ppm and 3333 ppm) so as to investigate the effect of feed concentration on the degree of fouling and thus its effect on the emissivity values measured on the membrane surfaces. Surface plots in 3D and Line plots are obtained for the measured emissivity values and thickness of the fouling deposit on the membrane surface respectively. The results indicate that the IRT technique is sensitive to changes that occur on the membrane surface due to deposition of contaminants on the membrane surface and that emissivity is a function of temperature, surface roughness and thickness of the specimen under investigation.


2021 ◽  
Author(s):  
Laura Namisnak ◽  
Sepideh Khoshnevis ◽  
Kenneth R. Diller

Abstract Various medical procedures are accomplished by manipulating skin temperature in a nonuniform pattern. Skin temperature monitoring is essential to assess conformance to protocol specifications and to prevent thermal injury. Existing solutions for skin temperature monitoring include single point sensors, such as thermocouples, and two-dimensional methods of sensing surface temperature, such as infrared thermography, and wearable technology. Single point sensors cannot detect the average temperature and consequently their measurements cannot be representative of average surface temperature in a nonuniform temperature field. Infrared thermography requires optical access, and wearable sensors may require complex manufacturing processes and impede the heat exchange with a source by introducing a layer of insulation. Our solution is a two-dimensional resistance temperature detector (2D RTD) created by knitting copper magnet wire into custom shapes. The 2D RTDs were calibrated, compared to one-dimensional sensors and wearable sensors, and analyzed for hysteresis, repeatability, and surface area conformation. Resistance and temperature were correlated with an R2 of 0.99. The 2D RTD proved to be a superior device for measuring average skin temperature exposed to a nonuniform temperature boundary in the absence of optical access such as when a full body thermal control garment is worn.


2018 ◽  
Vol 65 (2) ◽  
pp. 100-105
Author(s):  
Yoshihiro Takasugi ◽  
Koichi Futagawa ◽  
Takashi Umeda ◽  
Kouhei Kazuhara ◽  
Satoshi Morishita

Thermosoftening treatment of polyvinyl chloride (PVC) nasotracheal tubes (NTTs) can reduce the incidence and amount of epistaxis during nasotracheal intubation. The optimal thermal setting for thermosoftening treatment of NTTs without burn injury was investigated. Two composite types of PVC NTTs were used. Following withdrawal of the PVC NTTs from a bottle of water at 45 or 60°C, the changes in the surface temperature of the NTTs were measured by infrared thermography. Hardness of the NTTs at 25, 30, 35, and 40°C was measured. The incidence of epistaxis during nasotracheal intubation using thermosoftened NTTs was evaluated retrospectively. The surface temperature of both PVC NTTs dipped in 45 and 60°C water decreased to below body temperature 30 seconds after withdrawing them from the bottles. Although thermosoftening treatment proportionally decreased the hardness of both types of NTTs, the degrees differed according to their composition. When avoiding impingement of the NTT on the posterior wall of the nasopharynx, the incidence of mild and moderate epistaxis was 2.3%. Flexibility of PVC NTTs could be obtained by thermosoftening treatment at 60°C without burn injury. Thermosoftening treatment of PVC NTTs may be useful to avoid epistaxis during nasotracheal intubation.


2018 ◽  
Vol 85 (2) ◽  
pp. 201-203 ◽  
Author(s):  
Chunhe Yang ◽  
Gan Li ◽  
Xiaojun Zhang ◽  
Xianhong Gu

The objectives of the research reported in this Research Communication were to compare the variation of hind quarter skin surface temperature pre- and post- milking in dairy cows and to determine the optimal time to capture images by infrared thermography for improving the sensitivity and specificity of mastitis detection in dairy cows. Hind quarter infrared images of 102 Holstein dairy cows were captured from the caudal view by an infrared camera pre-milking and post-milking. The udder skin surface temperature was measured with the help of the image processing software. No significant difference was found between the left and right quarter skin surface temperature pre- and post- milking. The hind quarter skin surface temperature pre-milking was not significantly influenced by milk yield, but exhibited a rising trend along with the increase of milk yield. The hind quarter skin surface temperature post-milking was significantly influenced by milk yield. This leads us to conclude that the sensitivity and specificity of IRT in mastitis detection may be influenced by milk yield and it may be better to capture the infrared images of cow udders pre-milking.


Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5221
Author(s):  
Alexandra Lengling ◽  
Antonius Alfert ◽  
Bernd Reckels ◽  
Julia Steinhoff-Wagner ◽  
Wolfgang Büscher

Fattening pig husbandry and associated negative environmental impacts due to nitrogen inputs by ammonia emissions are current issues of social discussion. New resource-efficient feeding systems offer great potential to reduce excess nutrient inputs into the environment. Using ultrasound measurements, fattening pigs can be divided into performance groups based on their backfat/muscle ratio to feed them according to their nutritional needs. Ultrasound measurements are not suitable for practical use, so alternatives have to be found. As a non-invasive, contactless method, infrared thermography offers many advantages. This study investigated whether infrared thermography can be used to differentiate between “fat” and “lean” animals. Two evaluation methods with different measurement spot sizes were compared. During a fattening period, 980 pigs were examined three times with an infrared camera. Both methods showed significant differences. Body surface temperature was influenced by factors like measurement spot size and soiling of the animals. Body surface temperature decreased (−5.5 °C), while backfat thickness increased (+0.7 cm) in the course of the fattening period. Significant correlations (R > |0.5|; p < 0.001) between both parameters were found. Differentiation between “fat” and “lean” animals, based on temperature data, was not possible. Nevertheless, the application of thermography should be investigated further with the aim of resource-efficient feeding. The results of this feasibility study can serve as a basis for this.


Proceedings ◽  
2019 ◽  
Vol 27 (1) ◽  
pp. 3
Author(s):  
Tsai ◽  
Huang ◽  
Tai

Infrared thermography (IRT) has been widely employed to identify the defects illustrated in building facades. However, the IRT covered with a shadow is hard to be applied to determine the defects shown in the IRT. The study proposed an approach based on the multiplicated model to describe quantitively the shadow effects, and the IRT can be segmented into few classes according to the surface temperature information recorded on the IRT by employing a thermal infrared camera. The segmented results were compared with the non-destructive method (acoustic tracing) to verify the correctness and robustness of the approach. From the processed results, the proposed approach did correctly identify the defects illustrated in building facades through the IRTs were covered with shadow.


Sign in / Sign up

Export Citation Format

Share Document