The research of automatic sunlight collecting and illuminating system

Author(s):  
Yang Yanli ◽  
Xiao Na ◽  
He Huibin
Keyword(s):  
Author(s):  
J. M. Pankratz

It is often desirable in transmission electron microscopy to know the vertical spacing of points of interest within a specimen. However, in order to measure a stereo effect, one must have two pictures of the same area taken from different angles, and one must have also a formula for converting measured differences between corresponding points (parallax) into a height differential.Assume (a) that the impinging beam of electrons can be considered as a plane wave and (b) that the magnification is the same at the top and bottom of the specimen. The first assumption is good when the illuminating system is overfocused. The second assumption (the so-called “perspective error”) is good when the focal length is large (3 x 107Å) in relation to foil thickness (∼103 Å).


Author(s):  
N. Tamura ◽  
T. Goto ◽  
Y. Harada

On account of its high brightness, the field emission electron source has the advantage that it provides the conventional electron microscope with highly coherent illuminating system and that it directly improves the, resolving power of the scanning electron microscope. The present authors have reported some results obtained with a 100 kV field emission electron microscope.It has been proven, furthermore, that the tungsten emitter as a temperature field emission source can be utilized with a sufficient stability under a modest vacuum of 10-8 ~ 10-9 Torr. The present paper is concerned with an extension of our study on the characteristics of the temperature field emitters.


Author(s):  
K. Shiraishi ◽  
T. Katsuta ◽  
S. Ozasa ◽  
H. Todokoro

We have recently completed a newly designed 650KV electron microscope. An external view of this advanced instrument is shown in Figure 1. A symmetrical Cockcroft-Walton circuit has been adopted as the high voltage generator. The cathode is heated by high frequency power; a battery is not employed. The high voltage stability is better than 1 x 10-5/min.The sectional diagram of the column shown in Figure 2 is 420mm in diameter and 2750mm in height. The illuminating system consists of a double condenser lens and a magnetic alignment device. Dual deflector assemblies for dark and bright field images, selectable by push button, are built beneath the condenser lens. Two selectable stigmator power supplies are also provided for dark and bright field image operation.


Author(s):  
L. F. Allard ◽  
E. Völkl ◽  
T. A. Nolan

The illumination system of the cold field emission (CFE) Hitachi HF-2000 TEM operates with a single condenser lens in normal imaging mode, and with a second condenser lens excited to give the ultra-fine 1 nm probe for microanalysis. The electron gun provides a guaranteed high brightness of better than 7×l08 A/cm2/sr, more than twice the guaranteed brightness of Schottky emission guns. There have been several articles in the recent literature (e.g. refs.) which claim that the geometry of this illumination system yields a total current which is so low that when the beam is spread at low magnifications (say 10 kX), the operator must “keep his eyes glued to the binoculars” in order to see the image. It is also claimed that this illuminating system produces an isoplanatic patch (the area over which image character does not vary significantly) at high magnification which is so small that the instrument is ineffective for recording high resolution images.


2019 ◽  
Vol 374 (1769) ◽  
pp. 20180190 ◽  
Author(s):  
Rose Thorogood ◽  
Claire N. Spottiswoode ◽  
Steven J. Portugal ◽  
Ros Gloag

Obligate brood-parasitic cheats have fascinated natural historians since ancient times. Passing on the costs of parental care to others occurs widely in birds, insects and fish, and often exerts selection pressure on hosts that in turn evolve defences. Brood parasites have therefore provided an illuminating system for researching coevolution. Nevertheless, much remains unknown about how ecology and evolutionary history constrain or facilitate brood parasitism, or the mechanisms that shape or respond to selection. In this special issue, we bring together examples from across the animal kingdom to illustrate the diverse ways in which recent research is addressing these gaps. This special issue also considers how research on brood parasitism may benefit from, and in turn inform, related fields such as social evolution and immunity. Here, we argue that progress in our understanding of coevolution would benefit from the increased integration of ideas across taxonomic boundaries and across Tinbergen’s Four Questions: mechanism, ontogeny, function and phylogeny of brood parasitism. We also encourage renewed vigour in uncovering the natural history of the majority of the world's brood parasites that remain little-known. Indeed, it seems very likely that some of nature’s brood parasites remain entirely unknown, because otherwise we are left with a puzzle: if parental care is so costly, why is brood parasitism not more common?This article is part of the theme issue ‘The coevolutionary biology of brood parasitism: from mechanism to pattern’.


2012 ◽  
Vol 566 ◽  
pp. 505-510
Author(s):  
Hui Dan Cao ◽  
Yu Ming Shen

A new kind of device measuring liquid level automatically is developed which is composed of camera, illuminating system and industrial computer. It’s based on image measurement technology. The image of the transparent glass liquid level gauge which is installed on the volumetric tank of a flow calibration facility is captured by a camera. After a series of image pre-processing, such as interception, gamma correction, edge detection and so on, the value of liquid level which is the liquid level of the tank can be got by so called peak method. The measurement error is 0.1mm.


1945 ◽  
Vol 26 (7) ◽  
pp. 288-291
Author(s):  
Ronald L. Ives

Combination of a spirit-level type clinometer with a suitable illuminating system and battery produces an instrument better suited for ceiling light observations than the conventional unilluminated pendulum-type clinometer.


Sign in / Sign up

Export Citation Format

Share Document