Study on Detection Characteristics of Partial Discharge Detection System Based on Microfiber Coupler Sensor

Author(s):  
Yang Zhou ◽  
Yiying Liu ◽  
Na Wang ◽  
Junhao Li ◽  
Xutao Han
Author(s):  
Mochamad Zaeynuri Setiawan ◽  
Fachrudin Hunaini ◽  
Mohamad Mukhsim

The phenomenon that often arises in a substation is the problem of partial discharge in outgoing cable insulation. Partial discharge is a jump of positive and negative ions that are not supposed to meet so that it can cause a spark jump. If a partial discharge is left too long it can cause insulation failure, the sound of snakes like hissing and the most can cause a flashover on the outgoing cable. Then a partial discharge detection prototype was made in the cable insulation in order to anticipate the isolation interference in the outgoing cable. Can simplify the work of substation operators to check the reliability of insulation on the outgoing side of each cubicle. So it was compiled as a method for measuring sound waves caused by partial discharge in the process of measuring using a microphone sensor, the Arduino Mega 2560 module as a microcontroller, the LCD TFT as a monitoring and the MicroSD card module as its storage. The microphone sensor is a sensor that has a high sensitivity to sound, has 2 analog and digital readings, and is easily designed with a microcontroller. Basically the unit of measure measured at partial discharge is Decibels. The results of the prototype can be applied to the cubicle and the way it works is to match the prototype to the outgoing cubicle cable then measure from the cable boots connector to the bottom of the outgoing cable with a distance of 1 meter. Then the measurement results will be monitored on the TFT LCD screen in the form of measurement results, graphs and categories on partial discharge. In this design the measurement data made by the microphone can be stored with microSD so that it can make an evaluation of partial discharge handling in outgoing cable insulation.


2018 ◽  
Vol 4 (1(42)) ◽  
pp. 17-22 ◽  
Author(s):  
Yevgeniy Trotsenko ◽  
Volodymyr Brzhezitsky ◽  
Olexandr Protsenko ◽  
Vadim Chumack ◽  
Yaroslav Haran

Author(s):  
Roberto Candela ◽  
Antonio Di Stefano ◽  
Giuseppe Fiscelli ◽  
Stefano Franchi Bononi ◽  
Luca De Rai

2013 ◽  
Vol 303-306 ◽  
pp. 555-561
Author(s):  
Bin Liu ◽  
Yue Hu ◽  
Qian Chen ◽  
Wei Dong Zhang ◽  
Ling Yu Cao ◽  
...  

A portable acoustic-electric detection system for GIS partial discharge is developed. This system integrates both high and low-speed data acquisition devices, and is capable of multichannel joint detection of ultra-high-frequency and high-frequency current as well as ultrasonic signal generated during the GIS partial discharge process. The software of this system is developed based on LabVIEW. It can successively capture, acquire and store the pulse waveform of partial discharge, calculate the phase of discharge pulse and realize time-frequency analysis and amplitude-phase distribution analysis of PD signals at the same time. By calculating the time difference of multi-channel ultra-high-frequency (UHF) signals and of PD ultrasonic signals or the time difference between the two, the system is able to locate the PD source. This system has been applied to on-site partial discharge detection of 220kV and 500kV GIS substations, and the test results have verified the performance of the system.