7-GHz Measurement System for in-situ Space/Material Channel Characterisation

Author(s):  
Tanbir Bakth Nabil ◽  
Per Angskog ◽  
Jose Chilo
2019 ◽  
Vol 12 (11) ◽  
pp. 6113-6124 ◽  
Author(s):  
Fan Zhou ◽  
Shengda Pan ◽  
Wei Chen ◽  
Xunpeng Ni ◽  
Bowen An

Abstract. Air pollution from ship exhaust gas can be reduced by the establishment of emission control areas (ECAs). Efficient supervision of ship emissions is currently a major concern of maritime authorities. In this study, a measurement system for exhaust gas from ships based on an unmanned aerial vehicle (UAV) was designed and developed. Sensors were mounted on the UAV to measure the concentrations of SO2 and CO2 in order to calculate the fuel sulfur content (FSC) of ships. The Waigaoqiao port in the Yangtze River Delta, an ECA in China, was selected for monitoring compliance with FSC regulations. Unlike in situ or airborne measurements, the proposed measurement system could be used to determine the smoke plume at about 5 m from the funnel mouth of ships, thus providing a means for estimating the FSC of ships. In order to verify the accuracy of these measurements, fuel samples were collected at the same time and sent to the laboratory for chemical examination, and these two types of measurements were compared. After 23 comparative experiments, the results showed that, in general, the deviation of the estimated value for FSC was less than 0.03 % (m/m) at an FSC level ranging from 0.035 % (m/m) to 0.24 % (m/m). Hence, UAV measurements can be used for monitoring of ECAs for compliance with FSC regulations.


2010 ◽  
Vol 21 (10) ◽  
pp. 663-670 ◽  
Author(s):  
Jeffrey J. DiGiovanni ◽  
Ryan M. Pratt

Background: Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensogram. Real-ear measurements determine if prescriptive gain targets have been achieved. Starkey Laboratories introduced an integrated real-ear measurement system in their hearing aids. Purpose: To determine whether the responses obtained using the Widex Sensogram were equivalent to those obtained using current clinical threshold measurement methods. To determine the accuracy of the Starkey IREMS™ (Integrated Real Ear Measurement System) in measuring RECD (real-ear to coupler difference) values compared to a dedicated real-ear measurement system. Research Design: A verification design was employed by comparing participant data measured from standard, benchmark equipment and procedures against new techniques offered by hearing-aid manufacturers. Study Sample: A total of 20 participants participated in this study. Ten participants with sensorineural hearing loss were recruited from the Ohio University Hearing, Speech, and Language Clinic participated in the first experiment. Ten participants with normal hearing were recruited from the student population at Ohio University participated in both experiments. The normal-hearing group had thresholds of 15 dB HL or better at the octave frequencies of 250–8000 Hz. The hearing-impaired group had thresholds of varying degrees and configurations with thresholds equal to or poorer than 25 dB HL three-frequency pure-tone average. Data Collection and Analysis: The order of measurement method for both experiments was counterbalanced. In Experiment 1, thresholds obtained via the Widex Sensogram were compared to thresholds obtained for each participant using a clinical audiometer and ER-3A insert ear phones. In Experiment 2, RECD values obtained via the Starkey IREMS were compared to RECD values obtained via the Audioscan Verifit™. A repeated-measures analysis of variance (ANOVA) was used for statistical analysis, and a Fisher's LSD (least significant difference) was used as a post hoc analysis tool. Results: A significant difference between Sensogram thresholds and conventional audiometric thresholds was found with the Sensogram method resulting in better threshold values at 0.5, 1.0, and 2.0 kHz for both groups. In Experiment 2, a significant difference between RECD values obtained by the Starkey IREMS and the Audioscan Verifit system was found with significant differences in RECD values found at 0.25, 0.5, 0.75, 1.5, 2.0, and 6.0 kHz. Conclusions: The Sensogram data differ significantly from traditional audiometry at several frequencies important for speech intelligibility. Real-ear measures are still required for verification of prescribed gain, however, calling into question any claims of shortened fitting time. The Starkey IREMS does perform real-ear measurements that vary significantly from benchmark equipment. These technologies represent a positive direction in prescribing accurate gain during hearing-aid fittings, but a stand-alone system is still the preferred method for real-ear measurements in hearing-aid fittings.


2018 ◽  
Vol 26 (23) ◽  
pp. 30724 ◽  
Author(s):  
Jun Yu ◽  
Zhengxiang Shen ◽  
Xiaoqiang Wang ◽  
Pengfeng Sheng ◽  
Zhanshan Wang

2004 ◽  
Vol 16 (2) ◽  
pp. 267-275 ◽  
Author(s):  
Kaori Fukunaga ◽  
Takashi Maeno ◽  
Virginie Griseri

2014 ◽  
Vol 70 (a1) ◽  
pp. C1734-C1734
Author(s):  
Zoltan Gal ◽  
Tadeusz Skarzynski ◽  
Fraser White ◽  
Oliver Presly ◽  
Adrian Jones ◽  
...  

Agilent Technologies develop and supply X-ray systems for single-crystal diffraction research, including the SuperNova; a compact, highly reliable and very low maintenance instrument providing X-ray data of the highest quality; and the PX Scanner for testing and characterization of protein crystals in their original crystallization drops (in-situ). The SuperNova and PX Scanner are constantly improving, with recent enhancements including a new range of detectors using an Intelligent Measurement System. The Eos S2, Atlas S2 and Titan S2 detector range employs a smart sensitivity control of the electronic gain and is capable of instantaneously switching its binning modes thus providing unprecedented flexibility in tuning every exposure to provide the highest data quality for a wide range of experiments. We have also developed a completely new micro-focus X-ray source based on Gradient Vacuum technology, with novel filament and target designs. This novel source is an integral part of the new Agilent GV1000 X-ray diffractometer, which has been designed for applications that require even higher brightness of the X-ray beam.


Sign in / Sign up

Export Citation Format

Share Document